Find anything

Every lesson, worksheet, simulator and tool

Type a word: “flash cards”, “PLC”, “megger”, “tour”, or an ETO entry number like 4.12.

Lessons (135)

LessonAC and Three-Phase: What the Meter Is Telling YouDG2 at 59.3 Hz is an engine running slow. RMS and peak, true-RMS against average-responding on a UPS feed and a drive output, the voltmeter selector, and wye and delta windings.LessonArrangement DrawingsThe engine room’s electric equipment arrangement: read the sheet’s edges, find JB-12, GSP-1 and IO-2 by deck, frame and side, then trace three dead alarms to the one box they share and walk there.LessonBattery Load Test and ReplacementHawsepiper’s engine room 24 V bank on its real load: CH2 off, logged against August, done at 54 minutes. Then the one low cell, how each bank is tested, and the change, like for like.LessonBefore You Open the BoxMAC1 trips ten seconds after every start. Five minutes before the screwdriver: the drawing, the alarm history and the log, what changed last, and only then the box.LessonBoard-Level Repair: When There Is No Spare BoardFOP2’s power and output board, no spare and the exchange three weeks off: whose board it is, look then measure, the right parts and polarity, the iron and the job in order, and when to stop.LessonBus Tie and Rack-Out BreakersWhat a bus tie is for, every part inside an air circuit breaker, how it closes and trips, racking it out safely, and finding out why it won't close.LessonCables, Glands, Penetrations and the Cable NumberRead a marine cable inside out and a tag against the cable list, find what people did to a tray, judge five glands on a wet deck box, and find the hole a contractor left in an A-60 transit.LessonCalibrate or Replace a TransmitterDG2’s LO pressure transmitter has drifted: isolate, vent, take the as-found, chase zero and span until both hold, check the middle. Then pick a replacement that matches all five things.LessonControl Power: 110 V and 24 V DCThe board’s own 110 V DC supply and the automation’s 24 V: chargers and batteries through a blackout, reading the charger and battery ammeters, a charger that quit two days before anyone noticed, a blown control fuse, and six calls.LessonDC Grounds: Floating or Chassis-GroundedFloating 110 V and 24 V with + and − lamps, and the EDG engine’s 24 V with its negative on the block: pull breakers, split at junction boxes, meter across the device, hunt a short.LessonDeck Cranes: Hoist, Slew, Luff, Brakes, LimitsDeck crane CR1: whose parts are whose, a crane that cuts out slewed to port, the hoist chain, limits first from the diagnostic page, three valve-coil faults, and six calls.LessonECDIS Updates: Both Machines, Every TimeECDIS 2 two weeks behind ECDIS 1: the update path traced, weeks 44 and 45 loaded by the procedure, a missing permit found, then new software one machine at a time.LessonEngine Safety: Slowdown and ShutdownThe main engine’s own safety system: its sensors, the slowdown and shutdown lists, the bridge cancel and what it can’t cancel, a 02:10 stop traced to one switch, the test schedule, five calls.LessonEngines You’ll See: Telling the Families ApartHawsepiper’s three engine families, crosshead against trunk, speed class, reading a type designation, the free end and cylinder numbers, the seven day-one steps, and where each family keeps its trouble.LessonExchange and PA Faults: Find the Dead BitHawsepiper’s PA and telephone exchange, the next month: a dead zone relay, a wet forecastle horn found by splitting the line, a dead line-card port, and BDB-8 tripped behind a flat battery.LessonFans and BlowersNo. 2 ER supply fan, the boiler FD fan and an AHU: push an axial fan into stall, two centrifugal wheels with opposite amps, a reversed fan found by hand, a belt, a sticking fire damper, six readings.LessonFasteners, Gaskets and Packing: A Shop DrillRead bolt heads and pick a replacement; identify two threads; find a torque with its lubricant and unit; tighten LT1's feet across in three passes and a check round; cut a gasket; pack a fire pump gland to a drip; free a seized nut; five calls.LessonFilters and StrainersThe duplex strainer on the fuel supply pump suction: ΔP against dirt, flow, cold fuel and a tear; change over without losing suction; prove it dead with the QCV as third valve; five types; seven readings.LessonFive Ways to Talk: Internal CommsHawsepiper’s telephone exchange, PA, talkback, sound-powered phones and general alarm: how each works, what feeds it, what still talks in a blackout, and the two tests nobody else does.LessonFuel Injection: From Pump to FlameOn Hawsepiper’s camshaft main engine: build a jerk pump part by part, bar it round at three rack settings, pop test four fuel valves, read Pcomp, Pmax and exhaust as a pair, find a creeping rack linkage, compare an electronic engine, then find why No. 4 runs cold.LessonGalley and Laundry: The Calls the Crew SeesRange 1’s hotplate that only does Low, found in the selector switch; Range 2’s infinite switches; walk the cycle on a dishwasher, a combi oven and a dryer; a laundry GFCI that has found a washer.LessonGMDSS: The Station, the Radios, the BatteriesHawsepiper’s radio station: every set and what feeds it, the 24 V through a blackout and a dead ship, the three kinds of test, a failed MF/HF test call traced to the aerial, a charger that stopped charging.LessonGround HuntingWhat a ground is on an insulated ship and why one trips nothing; reading the ground lamps and the insulation monitor; splitting the 220 V board once you have the go-ahead; then the megger or the multimeter, and which one for what.LessonGround Lamps and the Ground HuntRead the three ground lamps and the insulation monitor, name the island a ground is on, half-split the board down to a wet deck light, and find a ground on a feeder that can’t be dropped with the leakage clamp.LessonGround, Short or Open: Which Do You Have?Let the symptom pick the test: ohms between conductors for a short, the megger to hull for a motor ground (multimeter for lighting), continuity end to end for an open. Then the readings that fool people.LessonGyro, Autopilot and Steering: One LoopFollow Hawsepiper’s steering round one loop: heading in, decision, command out, rudder back. Auto, FU, NFU and the flat; four complaints found by part; a slipped transmitter reset; the gyro brought back.LessonHand Tools and Measurement: A Hands-On DrillPick wrench, hammer and puller from the tool board; read a micrometer and a vernier caliper; set a valve lash with feelers; find a hub’s run-out with a dial indicator; work a torque figure for oil, an adapter and ft·lbf and tighten across the circle; count the board before box-up.LessonHeat ExchangersNo. 1 central cooler: four temperatures, two ΔPs and the five approach patterns; which way a LO cooler leaks running and stopped; on and off line in order; a plate pack closed to its dimension; seven readings.LessonHow Automation BreaksIs the reading wrong, or the plant? The six checks walked on DG2’s LO pressure over five days, an alarm that won’t clear set beside its limit, three nuisance trends, the first stop for every other symptom, and a dark cabinet traced back up its feed.LessonHow Bridge Gear Breaks: Symptom to First CheckThe Part 6 round-up: eight Hawsepiper cases on the book’s tree, then a dead echo sounder, four nights of alarms that are one feed each, a weak radio, and a radar that loses heading in a seaway.LessonHow Distribution BreaksPart 3 in one sitting: eight distribution symptoms sorted to their first check, then three walked on M/V Hawsepiper: a trip with nothing changed, a trip every start, and lights that dim and stay dim.LessonHow Hotel Systems BreakPart 7 round-up on Hawsepiper: sort eight calls into water, heat, vibration and neglect; then a UPS alarm, a fire panel fault, a tripping galley GFCI and a machine you have never seen.LessonHow Motors BreakPart 4 in one sitting: eight places a motor breaks, ten symptoms sorted to their first check, then three walked on Hawsepiper: hums and won’t turn, trips the breaker on start, runs, stops, runs.LessonHow to Use This SiteA short orientation: the three billets, the four learning stages, the ways in (by the book, by the ship, by the problem), what a lesson, plant tour, worksheet, simulator and Fault Bench each are, and where to start.LessonHVAC and Provision Plant RepairsFour repairs on Hawsepiper’s cooling: a part-winding compressor’s two contactors, a pressure switch isolated at its service valves and set by the gauge, a fan motor matched and turned the right way, a controller rewired and typed.LessonICCP, Shaft Grounding and Marine Growth PreventionThe hull’s own electrical system: hold the hull in its band, read four weeks of ICCP log, find a worn shaft brush from its millivolts, and change an MGPS anode that can’t hold its current.LessonIsolate a Loop Fault, Swap a Detector or Call PointLoop B’s drilled cable lost as B-008 to B-011: lift the section at ISO-2 and ISO-3, meter it, half-split at the bases to the drill hole, repair and confirm; then swap a dusty head and a cracked call point.LessonKeeping the Drawings TrueThe sludge pump won’t start and its sheet says it should: find the low-level cut-out nobody drew, red-line it, get it into the master set, then red-line the BWTS and the bigger AC breaker on E-101.LessonkW, kVAR, kVA and Power FactorThe meter-in-hand theory under the generator panel: two plates on DG1, SWP1’s triangle from a clamp and a voltmeter, a motor running light, a set at its ammeter limit with kW to spare, two sets not sharing kVAR.LessonLighting: Ballasts, LED Drivers and Wet FittingsInside a fluorescent, an LED and an incandescent fitting and which part fails; four purifier room fluorescents; two dead LED floods on the bench; 120 LED drivers that look like a ground; four wet deck floods.LessonLoad the MeterEighty volts on a deck lighting circuit you’ve just isolated: load the meter and watch the ghost collapse, then find the one that doesn’t; prove the meter live, dead, live; and four calls.LessonLubricants and Greases: The Right One, the Right AmountMatch the lube oil store to seven fill points, grades and BN against the fuel, three unlabelled cans, grease by thickener, grease LT1’s motor bearing by grams with the relief plug out, read what comes out, and put right a steering gear topped up with engine oil.LessonMake a Bronze Bushing on the LatheThe book’s worked example on M/V Hawsepiper: what to make aboard, the lathe made safe, the fits worked out, the tool on center and the speed, the bushing made in order, the micrometer read warm and cold, then fitted and five workshop calls.LessonMake Up a Cable End and GlandA deck box that filled with water through its gland: find the six faults in the old end, then make up the new one. Strip to the gland, braid into the cone, tighten and pull, ferrule, number, slack.LessonMegger a Motor and Dry It OutTest the emergency fire pump motor alone at 500 V for one minute, winding to frame and winding to winding, dry it out without cooking it, and read the curve: wet, ending or faulted.LessonMotor ControllersWhat an across-the-line starter does, start and stop with the seal-in, setting and resetting the overload, reversing with two interlocked contactors on the engine room crane, and the top faults.LessonOhm’s Law: The Missing NumberA purifier heater fuse with no rating on the drawing: meter the element, work out the current and pick the fuse. Three quick ones, then volts across a lug under load.LessonOne Fault at a Time, and the Second One Water MakesNo. 2 hold bilge pump won’t start: find one corroded terminal in the wet float box, fix it, test again from the load, and find the second it was hiding. Then three changes with no record, and an intermittent.LessonPackaged ControllersThe boiler, purifier, compressor and AC cabinets are the same inside: sort what is yours, the engineers’ and the maker’s; read a purifier’s alarm history and manual on three days; prove the common alarm reaches the ship after a cabinet change; five calls.LessonPhase Rotation: Prove It, Swap It at the MotorNo. 1 ER supply fan bumped backward after its cable was renewed: crossed cores found, two swapped at the motor. Then a reversed LT pump that sounds fine, and SWP1’s six leads by the drawing.LessonPID: Controller or Valve?The main engine jacket water swings five degrees either side of 85 °C the day after a positioner change. Read the shape of the swing, stroke the valve, and say whether it is the controller or the valve before anyone turns a knob.LessonPipe Work: Prove It Dead, Clamp It, Renew ItA pinhole in M/V Hawsepiper’s ballast discharge: prove the line dead, pick the repair the book allows on each service and who signs it off, fit a clamp on sound metal, thread a nipple to the right length, break and make up a flange in a star, test it and three calls.LessonPiping, Flanges and GasketsName five lines by magnet and eye; measure a bolt circle and find why the spare won't fit; pick gaskets for six joints; bolt a Cu-Ni flange in the star; a steam line growing between anchors; trace a leak; five pipe calls.LessonPlant Tour: Ballast and Ballast Water TreatmentWalk Hawsepiper’s ballast plant stop by stop on one drawing of the ship, from the sea chests through the ballast pumps, the filter and UV treatment system and the remote valves to the tanks, soundings and vents, the stripping eductor and the ballast console in the ship’s office: what to look at, what normal reads, a call at each stop; then nine sets of readings.LessonPlant Tour: Bilge, Oily Water Separator, Sludge and IncineratorWalk Hawsepiper’s bilge and sludge plant stop by stop on one drawing of the engine room, from the bilge wells through the holding tank, the separator and its 15 ppm monitor to the sludge tank, sludge pump, incinerator and Oil Record Book: what to look at, what normal reads, a call at each stop; then six sets of readings.LessonPlant Tour: Compressed AirWalk Hawsepiper’s compressed air plant stop by stop on one drawing of the engine room, from MAC1 and MAC2 to the air start valves and the control air header: what to look at, what normal reads, a call at each stop; then eight sets of readings.LessonPlant Tour: Fire ProtectionWalk Hawsepiper’s fire protection stop by stop on one side view of the aft end, from the fire pumps and the emergency fire pump to the fire main, CO₂, water mist, detection and the shutdowns: what to look at, what normal reads, a call at each stop; then eight sets of readings.LessonPlant Tour: HydraulicsWalk the hydraulic pattern stop by stop on deck crane CR1 cut open, with No. 2 hatch cover, its power unit and the engine room’s remote valve power unit beside it: tank, pump, filters, cooler, accumulators, relief, valves, actuators, hoses and the other users; then six sets of readings.LessonPlant Tour: Propulsion Beyond the EngineWalk Hawsepiper’s shaft line stop by stop on one side view of the aft end, from the thrust bearing and turning gear to the stern tube and the fixed-pitch propeller, with insets for a geared ship, a CPP ship and the bow thruster; then seven sets of readings.LessonPlant Tour: Refrigeration and HVACWalk Hawsepiper’s provision plant and air conditioning stop by stop on one drawing of the aft end, from the compressor round the cycle to the meat, veg and dairy rooms, then the AHU and the engine room supply fans: what to look at, what normal reads, a call at each stop; then six sets of readings.LessonPlant Tour: Seawater and Central CoolingWalk Hawsepiper’s cooling plant stop by stop on one drawing of the engine room, from the sea chests to the water treatment: follow the sea water, then the heat; a call at each stop; then seven sets of readings.LessonPlant Tour: Sewage and Gray WaterWalk Hawsepiper’s vacuum toilets and sewage plant stop by stop on one drawing of the aft end, from the toilets and vacuum piping to the collection tank, the treatment plant with its blower and float-run discharge pump, the chlorinator, the overboard valve and the gray water: what to look at, what normal reads, a call at each stop; then seven sets of readings.LessonPlant Tour: Steering GearWalk Hawsepiper’s steering gear stop by stop on one plan of the steering flat, with the bridge stand and the two boards beside it: control systems, power units and feeders, valve block, rams, stock and feedback, local control; then six sets of readings.LessonPlant Tour: The Electrical PlantWalk Hawsepiper’s electrical plant stop by stop on one drawing of the engine room and the accommodation above it, from the emergency generator to the shore connection: what to look at, what normal reads, a call at each stop; then six sets of readings.LessonPlant Tour: The Freshwater PlantWalk Hawsepiper’s freshwater plant stop by stop on one drawing of the engine room and the accommodation above it, from the sea chest and the evaporator to the hydrophore and the hot water loop: what to look at, what normal reads, a call at each stop; then nine sets of readings.LessonPlant Tour: The Fuel PlantWalk Hawsepiper’s fuel plant stop by stop on one drawing of the engine room, from the bunker manifold to the main engine: what to look at, what normal reads, a call at each stop; then five sets of readings.LessonPlant Tour: The Lube Oil PlantWalk Hawsepiper’s lube oil plant stop by stop on one drawing of the engine room, from the deck filling station to the waste oil tank: what to look at, what normal reads, a call at each stop; then seven sets of readings.LessonPlant Tour: The Main Engine as a LoopWalk Hawsepiper’s slow-speed two-stroke main engine as one loop, stop by stop on one drawing: air in, compression, injection, combustion and power, exhaust, the turbocharger and exhaust gas boiler, power out and the three supports; then eight sets of readings.LessonPlant Tour: The Steam PlantWalk Hawsepiper’s steam plant stop by stop on one drawing of the engine room, from the auxiliary boiler and the exhaust gas boiler to the hotwell and the blowdown: what to look at, what normal reads, a call at each stop; then seven sets of readings.LessonPreferential Trip and Load SheddingSort the feeders into stages and the never-shed list, watch a set trip and the board shed load to save the last set, the blackout without it, capacity before putting the load back, and why a set over its share can shed the galley.LessonProtective Relays: Read the FlagWhat each of the five generator relays watches; a reverse power trip after a slow close; overcurrent that rides through a motor start; the AVR’s relays against the governor’s; differential and its zone; a multifunction relay’s event log; and six trips to sort.LessonPull a Motor, Fit New Bearings, Line It UpNo. 1 LT pump’s drive-end bearing has gone. Mark it before it comes off, bench-test it, heat new bearings on, run it uncoupled, then align it: soft foot, angular, offset, torque, re-check.LessonRadar Reset, Magnetron Change, Unit SwapRadar S again: a frozen picture reset from the breaker, the 7,990-hour magnetron changed up the mast and tuned, and a new processor that needs the ship’s settings.LessonRadio Battery: The Load Test and the ChangeHawsepiper’s GMDSS reserve on load with the bridge: open BDB-10, log an hour against last time, confirm it charges. Then a bank that falls faster, a weak block, and the change like for like.LessonReading a Wiring Diagram and a LadderThe No. 1 LT pump starter drawn as a ladder and as a wiring diagram. Find each part on both, trace a rung, follow wire and terminal numbers, and go from the ladder to the right two screws.LessonReading the Switchboard Like a StoryFive meters on each generator panel and the stories they tell: equal kW with unequal amps, unequal kW at the right frequency, a plant near its limit, poor power factor, low volts on every set.LessonReefer Receptacles and the Monitoring SystemThe ship’s side of the reefers: the feeder to forty receptacles, the load on loading day, plugging in and out without burning pins, a rain ground found receptacle by receptacle, and the office screen read right.LessonRefrigeration and HVAC: A Motor and a Chain of SafetiesThe provision plant’s compressor rung opened one safety at a time; yours or the card’s; an HP trip read before the reset, an LP short-cycle settled at the sight glass, an iced coil traced to its timer.LessonRepair a 440 V Motor Cable: The Three-Tape MethodNo. 1 LT pump’s lead cracked at the gland: prove it dead at the motor, find the core, clean it, rubber twice and vinyl over, megger it, fix the gland. Then cooked leads in FOP2’s box.LessonRepair a Fixture; GFCI CircuitsThe accommodation ladder light: prove it dead at the fitting (it has two feeds), find how the water got in, ohm it to hull before it goes back on. Then how a GFCI decides, and the one that won’t stay in.LessonReplace a Breaker, Fuse, Relay or TerminalThe five things on a breaker label, a galley breaker swapped with the feeder above locked out; three fuses matched by type, rating and speed; MAC1’s trip relay matched by coil and contacts; a hot terminal.LessonReplacing Motor BearingsThe No. 1 LT pump motor’s drive-end bearing has gone. Mark it before it comes off, pull the old bearings with a puller, match 6311-C3 and 6211-C3, heat the new ones on to about 110 °C, run it uncoupled, then line it up.LessonRigging and Lifting: A Motor Out of the Engine RoomLT1’s motor goes ashore from M/V Hawsepiper: the gear inspected and three items tagged out, the weight from the plate, the chain block on the padeye, sling angles worked out, the load handed to the 5 t engine room crane, signals, the landing, and five calls.LessonRTDs and Thermocouples: Ohms and MillivoltsDG2’s temperature points sorted into Pt100s and thermocouples; GE224 ohmed against the table at both ends, then found linked as two-wire; No. 4 exhaust low and slow; a new thermocouple fitted.LessonSeries and Parallel: The Pump That Started by ItselfThe No. 2 hold bilge pump’s control rung: the series string, the hold-in and Hand in parallel. Then a pump running with the well dry and one that won’t run, each found with the meter.LessonShaft Generators: The Engine Doesn’t Care About 60 HzA sister ship with a shaft generator: slow the engine and watch the converter hold 60 Hz, set the condenser’s AVR, short a reefer feeder, then change over to the diesels before the pilot.LessonShore PowerProve rotation and fix it at the shore end, judge four berths’ volts and hertz, fit the load under a 400 A pier breaker, change over through a blackout, see why a ground trips on shore power, and find a warm lug.LessonSingle-PhasingThe No. 1 LT pump loses a phase: watch it keep running and fail to restart, see why in the stator field, settle four calls with the clamp meter, and find the open with the ohmmeter.LessonSolenoids, Limit Switches and ProxesProve a purifier’s solenoid valve with its LED, volts and ohms; change the coil; look at a hatch cover limit switch’s arm and cam before its contacts and set a new one; catch a PNP sensor on a card wired for NPN and set the gap; seven calls.LessonSource to Load: Where Every Fault LivesEvery circuit is a source, a path and a load. On the No. 2 HT pump starter: a dead control transformer, an open coil and an open selector contact, each found by the three questions in order.LessonStaying Alive: Lock-Out, Gas Tests, Hot Work and the AlarmsMake No. 1 SW pump safe: prove it dead, then block, bleed and prove zero on the sea side. Gas-test a double-bottom tank and read the permit, set up hot work on both sides of a bulkhead, find the hazards aloft, answer the alarms you must know, and decide go or don't go on eight jobs.LessonStored Energy and Arc Flash: Where It HidesFour places energy stays after the breaker opens: an ACB’s closing spring, a drive’s DC bus, a pump turned by back-flow, a battery bank. Then the arc-flash label on the main board.LessonSwap a Card, Force a Point, Back Up and RestoreNo. 1 hydrophore pump’s PLC: back up before you touch, swap a dead output card with its block still wired, set a new card’s address, force a failed float and clear it, restore after a flat battery.LessonSynchronizing and Load SharingPut No. 2 generator on the board: match voltage and frequency, close just before 12 on the synchroscope, share the kW with the governors and the kVAR with the AVRs, fix a backward droop CT, and sort six sets that won’t share.LessonTanks and Soundings: The Tape DecidesInside a double-bottom tank; take a sounding and check the reference height; sounding or ullage; table, trim and temperature to metric tons; tape against the TLI and the dead band; a painted vent at bunkering; five tank calls.LessonThe 4–20 mA Loop: Read It, Find the Break, Prove ItRead the milliamps before you climb the tank, read DG2’s LO pressure loop at every terminal, go card first, half-split a dead tank loop with volts across the pair, prove it with 4, 12, 20 mA.LessonThe Alarm Is a SymptomDG1’s HT outlet alarms at 97 °C on two nights: one false, found with the thermometer and a neighbor; one true, walked round the HT circuit to a three-way valve stuck on bypass.LessonThe Alarm System as a MapClimb the alarm system from a sensor to the cabin panel; put an unmanned night in order; read an alarm point list; find why an alarm never came (a block signal stuck on); inhibit, un-inhibit and the point someone forgot; where alarm ends and control begins; five calls.LessonThe Alternator in One Line: Two Loops, Three Machines and a BoxDG3 opened up: the power path from the PMG to the bus, the AVR’s loop working on a load step, the maker’s AVR sheet read part by part, a day-one walk round, and why you never megger through the AVR.LessonThe Bow ThrusterThe biggest motor on the board: whose parts are whose, why it never starts across the line, the start permit (all three sets, lever at zero), megger before the port, and the clamp on the first start.LessonThe Control SchematicMAC1’s starter on one control schematic: tap the eight loads, read back from the M coil, see what drawn de-energized means when running, find K2’s contacts by name, then find why it won’t start in Auto.LessonThe Emergency Generator ChainWatch the undervoltage relay open the tie, start the 250 kW set and close its breaker inside 45 seconds; sort the emergency board’s loads; check cranking volts; run the real test with the tie open and the load on; and name six quiet failures.LessonThe Fire Detection Panel: Loops, Addresses, InterlocksWhere Hawsepiper’s fire panel, relay unit, battery and feeds are; addresses on loop B; a drilled cable lost as a range between two isolators; what the panel stops and releases (never the CO₂).LessonThe Frequency Meter Test: Which Loop Is SickOn any generator complaint, look at the frequency meter first. Steady: the AVR side. Swinging or wrong: the engine side. Five complaints, each half walked, and what changes when two sets are paralleled.LessonThe GalleyRanges and their hotplate selectors, the oven and combi oven, the fryer and its high limit, the dishwasher, and the boiling pan (a steam-jacketed kettle): what each does, the core parts, and the faults you will be called for.LessonThe Half-SplitFind an open among sixteen points in four readings by testing the middle of what is left, find the masthead light’s open using only the boxes you can reach, and four calls on where to read next.LessonThe Induction Motor: Slip, Starting Current, TorqueWhy the rotor never catches the field, and how to read a motor’s load off a tach when the ammeter is dead. Then six to eight times on start, and torque with the square of the volts.LessonThe LaundryWashers (door lock, heater, drain pump, inverter motor), the dryer (heater, airflow switch, high limit, lint) and the laundry GFCI: what each part does, and the calls you get on a Sunday.LessonThe Loop DrawingDG2’s LO pressure, GE221, on its own loop sheet: follow it from transmitter to card, mark the test points in order, read the scale, half-split a dead loop at the test points, and find a loop with no sheet.LessonThe Main Board One-LineWhat each feeder on the main board protects, what else just lost power, inside a feeder cubicle, a crane feeder trip walked down to a wet junction box, why an open tie proves nothing, and six calls.LessonThe Nameplate and the OverloadRead the LT pump motor’s plate, clamp its amps against it, link the box for 440 V, work out a painted-over plate, then match a contactor and overload, set the dial and sort five motors that keep tripping.LessonThe Nav Sensors and the Feeds Between ThemWho talks to whom through Hawsepiper’s data distributor; read the sentences on a laptop; GPS 1 sending “no fix” traced up its antenna cable; transducer before display; two ECDIS that must match.LessonThe PLC and What Its Lights MeanNo. 1 hydrophore pump on a PLC: find the power supply, CPU, cards and port; read the LEDs through a good cycle; four mornings split by the lights; an input proved with the meter; five calls.LessonThe Radar as Blocks: Scanner, Magnetron and InputsRadar S on M/V Hawsepiper, block by block: one pulse round the set, a magnetron fading over six log pages, four wrong pictures traced to their block, and what on it is yours.LessonThe Ship’s NetworksTake a network switch down and see why there are two; measure and fix the resistors on an RS-485 Modbus chain; three silent devices (address, baud, polarity); a switch’s lights for power, cable or a duplicate IP; fiber tested with light; six calls.LessonThe Synchronous Machine: Two Sets of RulesThe same governor and AVR knobs on a set alone and on a set paralleled. The helper who raised the voltage, the set that motored, and six which-rules calls.LessonThe System Wiring DiagramDG1’s cubicle on sheet E-201: trace a phase from source to load, the CT loop through the ammeter and the 51 relay, the PT and its blown fuse, and the 110 V DC trip circuit; then find why the breaker didn’t trip with a meter, in two rounds.LessonThe Three-Wire StarterBuild a motor starter's control circuit one part at a time, see why it holds itself in and why it stays out after a blackout, then find the fault in a dead one with a meter.LessonThe Troubleshooting Method on One PageThe ETO book's Part 8 moves in one short lesson. Before you open the box, source to load, the half-split, voltage drop, load and prove the meter, one fault at a time, when to stop and call, and one practice fault on the No. 1 LT pump.LessonThe Ungrounded System: The Ground That Waited a WeekWhy Hawsepiper’s 440 V has no link to the hull: the first ground trips nothing, moves the hull and not the phases, and waits. Then two grounds make a short.LessonThe VFD from the OutsideThe ER exhaust fan’s drive: rectify, store, chop; the DC bus that outlives the power; the six parameter groups you touch; rotation at the motor leads; six fault logs; and the insulation alarm that comes with the bow thruster.LessonTransformers and the 220 V SideTwo transformer banks on two halves of the board and the interlocked changeover, half the volts and twice the amps, why a 220 V ground never shows on the 440 V lamps, a hot transformer checked in order, taking a bank out of service, and six calls.LessonTransmitters and SwitchesA number or yes or no; change a pressure transmitter on its valve and vent, and the standby it starts; four tanks where level lies by type; a flow switch that says no flow; set and differential on the air compressor; the path before the loop.LessonTroubleshoot a Battery ChargerHawsepiper’s engine room 24 V charger, CH2, opened up: door meters first, then four faults: a blown input fuse, a latched board and a cooked output fuse, a sense lead adrift, an open diode.LessonUPS Systems: Online, Line-Interactive, BypassUPS-1 under Hawsepiper’s alarm system: its path, battery and bypass, what a line-interactive unit lets through, the loads nobody designed for, and the battery that failed its test.LessonUsing a MeterVolts AC and DC on an insulated ship, proving dead live-dead-live, continuity and ohms on dead circuits, the door ammeter and the clamp, and the megger at 500 V, on the No. 1 LT pump starter.LessonValves: Open, Shut, and HoldingParts on a globe cut open; open or shut on seven valves; six valve types on the SW pumps and which you may throttle; symbols and the legend rule; the standby turning backwards; proving isolation past a slipped gearbox pointer; five calls and who does which job.LessonVDR, Nav Lights and the WhistleA VDR alarm traced to a wet wing microphone, the departure test of every nav light on both lamps, a sidelight found by lamp, gasket, panel and ohms to hull, and a silent whistle.LessonVocabulary: The Words on Day OneAbout forty electrical words you meet on your first day, learned by tapping the parts of a starter, the ship's power, a set of cards and a ladder rung, then a quick match.LessonVoltage Drop Across a ContactMeasure across each closed pole of the running LT1 contactor and find the pitted one dropping 14 V, work out the heat, see why it only shows under load, and sort six readings from a panel round.LessonWatertight Doors, Davits and the Boat BatteryA WT door that shows open on the bridge while it is shut, a davit limit that didn’t stop the hoist, a lifeboat battery dying behind a green davit plug, and a lift’s safety string.LessonWeld a Bracket, Cut a Seized NutA new pipe bracket on M/V Hawsepiper, start to finish: what not to weld, the hot work permit walk on both sides of the steel, the rod and the amps, the fillet and four beads read, then the gas set up, lit, cut with, shut down, and a flashback.LessonWhen to Stop, When to Call, How to Hand It OverRadar S’s display is dead. Prove the outside with a meter, swap in the spare, read code 17 and stop at the processor. Then the call that gets a part, and the handover the next person starts from.LessonWindlass, Mooring Winches and Hatch CoversMW3, the port aft mooring winch: what is yours on deck, two speeds and two overloads, a motor that hums against its brake, rain in the control station, and No. 2 hatch cover held by its own limit.LessonWye-Delta StartingA step-by-step lesson on wye-delta starting: why it exists, the six winding ends, the three contactors, setting the timer, what it can't start, and a fault to find.

Worksheets (8)

WorksheetTen QuestionsWorksheet. Match the ten questions to the sheets that answer them, answer all ten for M/V Hawsepiper without a drawing, find the one no sheet answers, and see which sheets to walk again. Then keep your own ten at the front of your turnover notes.WorksheetThe 45 SecondsWorksheet. Build M/V Hawsepiper’s blackout timeline from the moment the bus dies: the relay, the interconnector, the start, the bank, the breaker at 13 s. Sort what comes back by itself, then the standby set and the sequential restart, and the steering pump that didn’t come back. Then fill in and print your own.WorksheetThe Battery RegisterWorksheet. Find all twelve of M/V Hawsepiper’s batteries, from the emergency generator’s starting banks to the boiler controller’s memory cell, and put them on one page; read it for the oldest, the charger showing no current and the banks never tested on load; judge three load-test curves. Then fill in and print your own.WorksheetThe Bridge TableWorksheet. Walk M/V Hawsepiper’s wheelhouse and radio station and write every box’s breaker, UPS, data in, feeds, antenna and owner; then the gyro that loses power, six jobs sorted into yours and the contractor’s, and three calls. Then fill in and print your own.WorksheetThe Cabinet MapWorksheet. Mark M/V Hawsepiper’s alarm system cabinets and the makers’ controllers on a plan, with what each reads, what feeds it and its network; sort the inhibits and forces into explained and ask-the-Chief; then the twenty alarms from the purifier room. Then fill in and print your own.WorksheetThe Islands and the Control PowerWorksheet. Walk M/V Hawsepiper’s ground lamps and insulation monitors, AC and DC, and note today’s readings; answer four ground alarms from the sheet; fill in the four control supplies; find the dark panel’s fuse. Then fill in and print your own.WorksheetThe Megger LogWorksheet. Write the line (date, frame temperature, one-minute reading), plot five of M/V Hawsepiper’s motors over a year, bring them to the same temperature, and sort the steady, the wet, the falling and the one that only got warm. Then start your own log.WorksheetYour Own One-LineWorksheet. Walk M/V Hawsepiper’s two switchboards door by door, check your sheet against the yard one-line, settle each difference at the door, mark the halves, then fill in and print the sheet for your own ship.

Simulators (40)

Simulator · free playBattery ChargerFloat, boost and temperature compensation on a 24 V lead-acid bank, reading cell voltages and specific gravity, and finding out why a charger isn't charging.Simulator · free playBlackout DrillOverload a generator and watch preferential trip and the standby start; black out the ship and follow the emergency generator, bus tie and sequential restart against the 45-second clock.Simulator · free playBreaker Won't CloseAn air circuit breaker that won't close: read its flags, measure its coils and find which of eight interlocks or faults is stopping it. Then rack one out in the right order.Simulator · free playBrushless AlternatorFollow a brushless alternator's excitation chain from PMG to main field, test the rotating diodes with a meter, and diagnose six excitation faults.Simulator · free playCentral CoolingA ship's central cooling system: sea water, LT and HT fresh water circuits and their three-way valves. Change the load, then find the fault.Simulator · free playCrane ControlFault-find an all-electric crane hoist's control: emergency stops, limit switches, the overload limiter, hoist contactors and the spring-applied brake, with a meter on the ladder diagram.Simulator · free playElectro-Hydraulic Deck CraneDeck crane CR1, electro-hydraulic, 25 t: a wye-delta pump motor, the hydraulic power unit, a PLC with its lights and diagnostic page, valve coils, limits, the SWL limiter and the slip rings. Take a fault, find it with the meter, fix it and prove it.Simulator · free playEngine Safety SystemMain engine alarms, slowdowns and shutdowns: push the sensors past their limits, cancel from the bridge, find out what can't be canceled, and what a broken sensor wire does.Simulator · free playFault BenchStarters with a fault you cannot see: operate them, read volts, ohms and amps on any terminal, find the fault, fix it and prove it. Twelve circuits (across-the-line pump, hold bilge pump on floats, wye-delta, a standby pump that starts on low pressure, a starting air compressor with its unloader and trips, and the sewage plant three ways: on floats with its blower, and two timer-run plants; the engine room crane hoist, reversing, with its limits and brake; a generator breaker's closing and tripping circuits in TEST; and an alarm system cabinet with two 4–20 mA loops and two switch inputs; and a hydrophore pump run by a PLC, where the program is your meter) and 250 faults at random.Simulator · free playFiring OrderSee a six-cylinder marine diesel's firing order: crank throws from the end, pistons from the side, and which unit is on its power stroke.Simulator · free playFollow the WireChase a hold bilge pump fault through a schematic, a terminal diagram and a cable list: sheet-and-column cross-references, wire numbers, terminal strips and cable numbers.Simulator · free playFresh Water GeneratorStart and stop a jacket-water-heated vacuum fresh water generator step by step, watch the vacuum and boiling point, and diagnose nine common faults.Simulator · free playGauges to DiagnosisTurn refrigeration gauge and thermometer readings into superheat, subcooling and a ranked list of likely faults.Simulator · free playGenerator ProtectionRead the trend before a generator trip and name the protection that operated, then set a generator breaker’s overcurrent curve so it rides through a motor start but still discriminates with the feeders.Simulator · free playGovernor KnobsThe four knobs on a Woodward UG-type governor, live on a 750 kW generator: speed setting, droop, load limit and compensation. Stop the hunting, set 3% droop, and see the 2301A equivalents.Simulator · free playGround HuntRead the ground lamps and insulation monitor on an ungrounded ship's system, hunt a ground breaker by breaker, and tell a ground from a short or an open.Simulator · free playIndicator Card LabRead slow-speed diesel indicator cards: compare units, spot the bad one and name the fault.Simulator · free playInduction MotorTorque, current and slip of an induction motor as the load and voltage change, how to read the nameplate and set the overload, and how to prove a single-phased motor.Simulator · free playLadder LogicRead a live ladder diagram for the No. 2 cargo hold bilge pump with Hand-Off-Auto, a seal-in, an overload, a run timer and a silenceable alarm, then fix five broken rungs.Simulator · free playLine It Up: Fuel OilLine up a ship's fuel oil transfer and purifier system valve by valve, then find the fault in a bad lineup.Simulator · free playLoop CheckA 4–20 mA loop from supply to card: scale the signal, find the break with a voltmeter, and run a five-point transmitter calibration with as-found and as-left.Simulator · free playMotor Starter Fault HuntTroubleshoot a three-phase motor starter with a virtual meter: find where the voltage stops and name the fault.Simulator · free playParallel the GeneratorsBring a ship's second diesel generator onto the board: match voltage, watch the synchroscope, close the breaker and share the load.Simulator · free playPID TuningTune a jacket-water temperature controller: gain, integral and derivative on a live loop with load changes, a hunting as-found setting and a sticky valve.Simulator · free playPLC ProgrammerLearn to write ladder logic from zero. Follow along: twenty-two short guided exercises that tell you exactly what to press, from what a PLC is to contacts, coils, branches, the seal-in, NC wiring, the scan, memory bits, timers, latches, counters, the one-shot, alarm logic, numbers and math, 4–20 mA scaling, an analog alarm with a deadband, a step sequence, and the watch and force tables; skip any you know. Then build it yourself: eleven jobs on the ship's machinery, from a starter and a hold bilge pump to wye-delta, run hours, a hydrophore on a pressure transmitter, tank level alarms with a sensor fault and MAC1's auto start sequence, each checked by tests.Simulator · free playPLC RackSinking and sourcing inputs with PNP and NPN sensors, reading a PLC rack's LEDs to split a fault between field and PLC, and the safe order for swapping a card or forcing a point.Simulator · free playProvision PlantRun a ship's provision refrigeration plant with three rooms, pump-down control and a live control ladder, then diagnose eight common faults.Simulator · free playPump LabStart a centrifugal pump the right way, compare it with a positive displacement pump against a closed valve, and see why two pumps in parallel don't double the flow.Simulator · free playPurifier Gravity DiscSee how oil density, temperature and gravity disc size move the oil-water interface in a purifier bowl.Simulator · free playRTD and ThermocouplePt100 resistance and lead-wire errors in 2, 3 and 4-wire circuits, type K thermocouples with cold junction and the wrong extension wire, and a temperature sensor fault hunt.Simulator · free playShore PowerTake the ship onto shore power: check voltage, frequency and rotation, cut the load to what the shore breaker can carry, transfer, and recognize the expected ground.Simulator · free playStarting AirLine up, blow through and start a two-stroke main engine on 30 bar air, see why air start valves overlap, and diagnose seven starting air faults.Simulator · free playSteering GearAn electro-hydraulic steering gear with two power units: steer it, run the SOLAS swing test, and handle a leak, a trip and a follow-up failure.Simulator · free playSwitchboard MeterskW, kVAR, kVA, amps and power factor on the generator panel: build the load and watch the power triangle, then read two paralleled generators and fix uneven kW and kVAR sharing.Simulator · free playThe MeterPick the right tool, dial position and jack for 16 ship jobs, see phantom voltage and LoZ, find a burnt contact by voltage drop, and put prove-dead in order.Simulator · free playThree-PhaseRotating phasors and sine waves, RMS and peak, wye and delta line and phase values with practice problems, and phase rotation: why swapping two leads reverses a motor and three don't.Simulator · free playTiming WheelTurn the crank and see valve, port and injection timing on two-stroke and four-stroke marine diesels.Simulator · free playTwo-Stage Air CompressorRun a two-stage starting air compressor and diagnose leaking valves and fouled coolers from stage pressures and temperatures.Simulator · free playVariable Frequency DriveInside a VFD: rectifier, DC bus and PWM inverter. See the harmonics a drive puts on a ship’s bus, set one up from a motor nameplate, and work out why it tripped.Simulator · free playWye-Delta StarterStart a motor across the line, wye-delta, soft-start or by autotransformer and compare the current, find the fault in a wye-delta starter, and set a purifier’s overload bypass timer.

Tools (7)

The ship (2)