Three levels. An alarm tells the watch. A slowdown asks the engine to come down to a safe speed (on many ships the bridge has to do it when asked). A shutdown cuts the fuel.
Separate sensors. The safety system has its own pressure switches and sensors, independent of the alarm and monitoring system, so one failed sensor can’t both hide a problem and fail to act on it.
Cancel. In an emergency (a narrow channel, a collision about to happen) the bridge can cancel most slowdowns and shutdowns and take the risk to the engine instead. Overspeed, loss of lube oil pressure and the emergency stop can never be canceled here; on a US-flag ship 46 CFR 62.35-50(d) bars any override of the overspeed and lube oil pressure trips.
Wire break monitoring. Each safety input has a resistor at the sensor so the system can tell an open contact from a cut wire. A broken wire gives a “sensor fault” alarm, not a shutdown in the middle of a channel.
Reset only works once the cause has cleared, and the engine has to be brought back to stop before it will start again.
| Example settings | Alarm | Slow | Shut |
|---|---|---|---|
| LO inlet pressure | 1.8 | 1.6 | 1.4 bar* |
| Thrust bearing | 75 | 80 | 90°C |
| JW outlet | 90 | 95 | – |
| Oil mist | 70 | 100 | – |
| Overspeed | – | – | 109%* (114 rpm) |
Example figures only; your engine’s alarm and safety list has the real ones. *Cannot be canceled.