Started 16 November 2026. Every page was read for rules, safety limits, standard figures and worked sums, and each was checked against a source: the CFR, SOLAS, MARPOL, the standards, or a maker’s manual. Made-up readings for M/V Hawsepiper are teaching values and are not listed. So far: 487 claims confirmed, 14 corrected, 197 not yet verified (the source could not be reached, so the page was left as it was). Maker’s manuals and your ship’s procedures always win.
Every page
Open a page’s line to see each claim, the verdict and the source.
AC and Three-Phase: What the Meter Is Telling YouChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: 59.3 x 120/8 = 889.5 rpm; 440 x 1.41 = 622 V; 120 degrees = 5.6 ms; 359 V peak; 1.11 form factor; 35/1.73 = 20.2 A; 760/1.73 = 439 V (arithmetic re-worked)
unverified: Nothing rated under 600 V on the switchboard; CAT III 600 V the least (IEC 61010 (not fetched)) Practice rule.
confirmed: An average-responding meter reads low on peaky current; phase-to-hull volts wander on an ungrounded system (arithmetic and physics) 5.4 A against 8.4 A is 36 % low; consistent with the 1.11 form-factor scaling.
Arrangement DrawingsChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: Frames counted from aft rising forward; the ship wins over the drawing, red-line it (convention; book practice) Frame numbering from aft is the usual convention, not universal.
Battery ChargerChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: 12 cells: 2.25 V/cell = 27.0 V, 2.27 = 27.2 V; 3 mV/cell/C = 36 mV/C; 30 C float about 2.23 V/cell; shorted cell pushes other eleven to 2.40 V; 20 A on 200 Ah = 10-hour rate (arithmetic checked by hand)
unverified: Float 2.25 (flooded) / 2.27 (VRLA), boost 2.35-2.40, end voltage 1.75 V/cell, SG 1.270 / 1.200 / 1.120, replace under about 80% capacity, NiCd about 1.4 V/cell (no primary source reached this session; not changed) Typical maker and IEEE 450 figures; page tells the reader to use the battery label
Battery Load Test and ReplacementChecked in part · 4 confirmed · 0 corrected · 1 not verified
confirmed: Typical lead-acid float 2.25 V a cell, 27.0 V on a 24 V bank; boost 28.1 V (2.34 V a cell) below the 2.40 V equalize figure (East Penn AVR45/HT45 manual: float 2.25 V/cell, equalize 2.40 V/cell, end voltage 1.75 V/cell at 25 C https://www.eastpennmanufacturing.com/wp-content/uploads/AVR45-HT45-Single-Cell-Railway-Utility-IO-2727.pdf)
confirmed: End volts 21.6 V on a 24 V bank = 1.8 V a cell (East Penn AVR45/HT45 manual: float 2.25 V/cell, equalize 2.40 V/cell, end voltage 1.75 V/cell at 25 C https://www.eastpennmanufacturing.com/wp-content/uploads/AVR45-HT45-Single-Cell-Railway-Utility-IO-2727.pdf) Makers quote 1.75 V/cell (East Penn) or 1.70 (Crown) as the end voltage; 1.8 is the ship's more cautious teaching value. Arithmetic right.
unverified: Fully charged cells read SG 1.255 to 1.270 (Crown manual gives 1.275 to 1.290 for its traction cells: Crown industrial battery service manual https://www.crownbattery.com/ty-industrial-battery-service-manual) Full-charge SG depends on the maker (about 1.215 to 1.290 across stationary and traction types). Teaching value is plausible, but the label on the real battery rules. Not changed.
confirmed: Top up with distilled water only; open cells give off hydrogen, no flame or spark (Crown industrial battery service manual https://www.crownbattery.com/ty-industrial-battery-service-manual)
confirmed: 1.265 - 1.185 = 0.080; 20.0 A = 9.0 + 11.0 (Arithmetic re-computed by the auditor)
Before You Open the BoxChecked · 2 confirmed · 0 corrected · 0 not verified
confirmed: Make the plant safe first (change over to the standby) before the five minutes with the drawing (read in full on the second pass; procedure or ownership rule, no outside standard applies)
confirmed: A fuse that differs from the drawing is not changed back or up without finding why (read in full on the second pass; procedure or ownership rule, no outside standard applies)
confirmed: SOLAS: emergency generator started and connected automatically within 45 seconds (SOLAS II-1/43 as quoted at https://samkmoodle.samk.fi/mod/page/view.php?id=22189 (secondary))
confirmed: On most cargo ships nothing covers the gap; passenger ships and some newer cargo ships carry a battery (transitional source) (SOLAS II-1/43.3.1.3 and 43.4, Netherlands government treaty text https://wetten-overheid.nl/wet/BWBV0003264/artikel/43; passenger ships: SOLAS II-1/42 as carried into Directive 2009/45/EC, https://www.legislation.gov.uk/eudr/2009/45/annex/I/chapter/2/adopted) Cargo ships need a transitional battery only if the emergency generator cannot start and take the load within 45 s; passenger ships with a generator always need one (half an hour). The page's rule is right; 'most' and 'some newer' are its own judgment
unverified: An 85 C electrolytic dries out in a fraction of the life of a 105 C one; reversed electrolytic vents (Capacitor makers' lifetime rule (not fetched)) Standard (life doubles per 10 C); no source fetched.
unverified: Capacitor within 10 to 20 percent of the plate is live (Book rule ETO 0.13) Book's rule of thumb, not a standard.
confirmed: 900 kW 0.8 pf = 1,125 kVA, 1,476 A; diode test 0.4-0.7 V forward, OL reverse (arithmetic checked by hand) Diode figures typical; field-flashing steps defer to the maker and were not audited against a manual
Bus Tie and Rack-Out BreakersChecked in part · 1 confirmed · 0 corrected · 2 not verified
unverified: Bus-side stabs stay live with the breaker racked out; closed breaker cannot be racked; trip-free (maker-generic practice, no single primary source) Qualitative, consistent with draw-out ACB design; no numeric claims.
unverified: Rack-out order: trip open, discharge the spring and read the indicator, rack to TEST then DISCONNECTED, shutters down, lock and tag; believe the flag on the breaker, not the mimic (generic draw-out ACB practice; no single primary source) No rule or maker text found that contradicts it; generic practice, maker's manual governs. Note: lesson-stored-energy discharges the spring after racking out (close then open, clear of the bus); both orders are used by makers. The two lessons could say 'as the maker's manual orders'.
confirmed: Tie closes only in sync or with one side dead; never bridge the sync-check contact (46 CFR 111.30-25(d) requires synchronizing gear for paralleled generators; USCG PRG E2-21) Rule requires the gear; 'never bridge' is practice.
Cables, Glands, Penetrations and the Cable NumberChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: A-60: steel, stops smoke and flame, far side stays cool for sixty minutes (SOLAS II-2/3.2 as reproduced by the UK MCA: https://assets.publishing.service.gov.uk/media/5a81a413ed915d74e33ff4d1/Regulation_3_-_Definitions.pdf) Steel or equivalent; no smoke or flame to the end of the one-hour test; insulated so the unexposed side rises no more than 140 C average / 180 C at any point within 60 min.
unverified: A watertight bulkhead is only passed through an approved transit or penetration piece; a transit is approved as one system (maker's blocks only); reseal before leaving the space (SOLAS II-1/13 and type-approval practice, text not fetched) Matches normal class practice; low risk.
Central CoolingChecked · 1 confirmed · 0 corrected · 0 not verified
confirmed: About 6 MW of heat at full load; LT 36 C, HT 85 C (97 F, 185 F) (arithmetic) Model: 2,000 kW HT + 4,000 kW LT = 6,000 kW; LT rise 18 K at 80 kg/s, HT rise 12 K at 40 kg/s; unit conversions right. Setpoints are labeled typical.
Control Power: 110 V and 24 V DCChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: Charger/battery ammeter readings and 122 V float on a 110 V system (arithmetic re-worked) Teaching values, self-consistent.
unverified: Read charger and battery ammeters daily; replace fuses like for like; a fuse that blows again means a fault (book practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
DC Grounds: Floating or Chassis-GroundedChecked in part · 1 confirmed · 0 corrected · 2 not verified
confirmed: 122 V shared as 61 V per lamp; grounded pole lamp dark (arithmetic re-worked)
unverified: No megger on 24 V instrument loops (maker practice)
unverified: Floating DC: one ground trips nothing, two is a short; open two-pole breakers one at a time, engine safety last and only with the Chief and bridge; chassis-grounded engine DC blows a fuse instead (book practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
confirmed: 24 V across a 22 ohm coil; wye-delta pump start; isolation points (arithmetic checked by hand) All values invented for teaching; self-consistent
Engine Room Flash CardsChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: OWS discharges at under 15 ppm; oil content monitor stops discharge above 15 ppm (https://www.law.cornell.edu/cfr/text/33/151.10)
unverified: Insulation tester puts 500 or 1,000 V DC on a circuit; ground lamps: one dim, two bright = grounded phase; starting air about 30 bar; HT water 80 to 90 C General practice; not source-checked. Note: card lists 'HFO' as a shop name for heavy fuel oil, which is a style-rule matter for the coordinator, not a fact error.
Engine Safety SystemChecked in part · 2 confirmed · 1 corrected · 1 not verified
confirmed: Overspeed can never be canceled from the bridge (SOLAS II-1/31.2.10 (text at https://wetten-overheid.nl/wet/BWBV0003264/artikel/31); 46 CFR 62.35-50(d)) SOLAS: officer must have 'an opportunity to manually intervene' except where intervention would cause total failure within a short time, 'for example in the case of overspeed'.
corrected: Simulator let the bridge cancel the lube oil low-low shutdown (can:true), and the quiz taught that it may be canceled (https://www.law.cornell.edu/cfr/text/46/62.35-50) 46 CFR 62.35-50(d), as returned by the fetch in two pieces: "Override of overspeed and loss of forced lubrication pressure safety trip controls must not be provided for main propulsion" + "or generator steam or gas turbines, or diesel engines." Paragraph (c): "Loss of forced lubrication safety trip controls must be provided for main propulsion turbines and main propulsion" + "diesel engines." Table 62.35-50, main propulsion diesel row: safety control 'Manual trip', see (c), (d). Changed: LO sensor can:false; log shows '(cannot be canceled)'; Cancel paragraph and settings table now mark LO; quiz question answer reversed. Matches lesson-engine-safety-system and Hawsepiper part 3 table.
confirmed: Overspeed 109% of 105 rpm is about 114 rpm (arithmetic) 114.45.
unverified: Emergency stop cannot be canceled; thrust bearing shutdown cancellable Maker/class list decides; not source-checked.
Engine Safety: Slowdown and ShutdownChecked in part · 3 confirmed · 1 corrected · 1 not verified
confirmed: 109% of 105 rpm is about 114 rpm (Arithmetic re-computed by the auditor)
confirmed: Pt100: 134.7 ohm is 90 C; 137.3 ohm is 97 C (IEC 60751 Pt100 table (alpha 0.00385), as published at https://www.dwyeromega.com/de-de/resources/pt100-table/)
confirmed: Overspeed can never be canceled (46 CFR 62.35-50(d) https://www.law.cornell.edu/cfr/text/46/62.35-50) 46 CFR 62.35-50(d): override of overspeed and loss of forced lubrication pressure trips must not be provided for main propulsion diesel engines. The emergency stop (manual trip) is listed as a required safety control; its non-cancellable status follows from the same table but is not stated in words.
corrected: 'On this engine the low-low LO shutdown is one the bridge may cancel' (step 3: engine keeps running with CANCEL on) (46 CFR 62.35-50(d) https://www.law.cornell.edu/cfr/text/46/62.35-50) WRONG for a US-flag ship: the rule bars an override of the loss-of-lube-oil-pressure trip. Changed the event so the engine stops (answer, explanation, log line), the follow-up question to 'a canceled slowdown', and the closing line to 'Overspeed, lube oil pressure and emergency stop: never'. Rebuilt, chk and walk clean. The Engine Safety System simulator (src/engine-safety.html, not my page) still lets LO shutdown be canceled: report to its owner.
unverified: Setpoints and logic fixed by maker and class; never link out a safety input (Class machinery rules (not fetched)) Book's rule; consistent with practice.
Fans and BlowersChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: Vibration on anti-vibration mounts: about 6 good, 12 investigate, 12.5 stop (mm/s rms) (https://wittfan.de/files/pdf/Know-how%20Center/Normen%20und%20Richtlinien/04_Maximal%20zul%C3%A4ssige%20L%C3%BCfterschwingungen%20gem.%20ISO%2014694ISO%2010816-3_DE-EN.pdf) ISO 14694 BV-3 flexibly mounted: alarm 11.8, shutdown 12.5 confirmed. The start-up figure I could reach reads 3.5 (the page's 'about 6' matches 6.3, which I could not confirm from a source). Left as is; worth a look at the standard.
confirmed: Belt deflection about 15 mm per meter of span: 0.8 m = 12 mm (arithmetic checked) The 1/64 in per inch rule (15.6 mm/m) is the belt makers' usual; not fetched.
unverified: Axial fan in stall: amps rise; backward-curved amps fall when restricted; forward-curved overloads at free flow (fan engineering texts; not fetched)
confirmed: 27 A = 60 % and 38 A = 85 % of 45 A plate (arithmetic checked)
confirmed: 10.9: about 1,000 MPa (1,040 minimum), yield 90 % (https://www.trfastenings.com/knowledge-base/metric-screws/screws-and-bolts-mechanical-properties (ISO 898-1 table))
confirmed: 4.6: 400 MPa (https://www.trfastenings.com/knowledge-base/metric-screws/screws-and-bolts-mechanical-properties (ISO 898-1 table))
unverified: SAE grade 5 about 830 MPa (120 ksi), three radial lines; grade 8 about 1,035 MPa (150 ksi), six lines (SAE J429; portlandbolt.com page was not fetchable) 120 ksi = 827 MPa and 150 ksi = 1,034 MPa by conversion; markings are the standard ones but no source text was reached.
unverified: A2/A4-70 stainless 700 MPa, far less yield than 8.8 (ISO 3506-1 not fetched)
confirmed: G½ (BSPP): 55°, parallel, 14 tpi, 20.9 mm; ½ NPT 14 tpi 60° tapered; BSPT and NPT share pitch at ½ and ¾ in (https://en.wikipedia.org/wiki/British_Standard_Pipe (BS EN ISO 228 figures; secondary)) G½ major diameter 20.955 mm, 14 TPI, 55°, rounded crests; NPT figures (ASME B1.20.1) not fetched.
confirmed: Pump gland drip 8-12 drops a minute per inch of shaft: 45 mm = 14-21 (arithmetic checked) The 8-12 per inch rule itself is the book's; not source-checked.
unverified: Stainless A2/A4-70 takes about two-thirds of the 8.8 torque (not fetched) Consistent with yield 450 vs 640 MPa.
confirmed: Steering motor: overload and phase failure give alarms, never a trip; short-circuit protection only (SOLAS II-1/29-30, full-text mirror https://samkmoodle.samk.fi/mod/page/view.php?id=20572 (secondary)) Overload alarm only and short-circuit protection confirmed; the phase-failure alarm (II-1/30.3) was not on the mirror page read, so that part is unverified
confirmed: Steering pump restarts by itself when power comes back: 'what the rules ask' (SOLAS II-1/29-30, full-text mirror https://samkmoodle.samk.fi/mod/page/view.php?id=20572 (secondary))
confirmed: One steering circuit may be fed through the emergency switchboard (No. 2) (SOLAS II-1/29-30, full-text mirror https://samkmoodle.samk.fi/mod/page/view.php?id=20572 (secondary))
confirmed: Wye-delta: main/delta contactor pole carries 58% of line current (arithmetic checked by hand) 1/1.732
confirmed: Galley oven: 2 kW element at 440 V = about 97 ohm; one line lost = 3 kW of 6; one element open = 4 kW; 73 V drop gives 1.8 kW of 2.6 (arithmetic checked by hand)
confirmed: Laundry heater 9.7 ohm at 220 V = about 5 kW, 22.7 A (arithmetic checked by hand)
confirmed: Steering motor 30 kW 50 A; single-phased about 85 A (1.7x); locked rotor about 280 A (arithmetic checked by hand) Teaching values, self-consistent
confirmed: Failed transmitter parks at 3.6 mA; AMS calls BAD under 3.8 / over 20.5 mA (NAMUR NE 43 as summarized at https://www.electricalvolt.com/what-is-namur-ne-43 (secondary; NE 43 itself is paywalled)) 3.8-20.5 mA is the NE 43 measuring band, 3.6 / 21 mA the failure signals
confirmed: Megger motor at 500 V; windings under 'the book's 2 MOhm floor' (IEEE 43 as summarized at https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums (secondary)) 500 V DC for windings up to 1 kV confirmed. IEEE 43 minimum is 5 MOhm at 40 C for most windings built after about 1970; the 2 MOhm floor is the book's own figure, not audited here
confirmed: ANSI 27 undervoltage relay, 86 lockout relay on the ACB circuit (GE Multilin ANSI device number reference, https://gevernova.com/grid-solutions/multilin/notes/ref/ansi.pdf) 27 undervoltage, 86 locking-out relay
Firing OrderChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: Six-cylinder two-stroke fires every 60 degrees (360/6), four-stroke every 120 (720/6) (arithmetic)
confirmed: 1-5-3-6-2-4 on inline six-cylinder four-strokes (Nunney, Light and Heavy Vehicle Technology (2007), via https://taylorandfrancis.com/knowledge/Engineering_and_technology/Mechanical_engineering/Firing_order) Gives 1-5-3-6-2-4 or 1-4-2-6-3-5 at 120 degrees.
unverified: 1-5-3-4-2-6 common on six-cylinder two-stroke crosshead engines (MAN B&W project guides (Scribd copies not readable)) Three attempts, no readable maker text. Page already says makers differ.
Fresh Water GeneratorChecked in part · 2 confirmed · 0 corrected · 2 not verified
confirmed: About 90% vacuum, sea water boils at around 45 C (Antoine equation / steam tables) 10.1 kPa abs gives 46 C.
confirmed: No water-making within 20 nautical miles of the coast, in port or in estuaries (UK MCA MGN 397, https://assets.publishing.service.gov.uk/media/5a7c7101e5274a5590059e2e/mgn397.pdf) MGN: 'Twenty miles from land is generally considered to be a safe distance'. Ports/estuaries are the book's wording.
unverified: Typical figures: 85 to 93% vacuum with the shell at 44 to 46 C (hawsepiper-book ch07 table) From the book. The two ranges do not line up: 44-46 C is 90-91% vacuum; 85% is about 54 C, 93% about 39 C. Reported as a suspected book erratum; page not changed.
unverified: Salinity dump set point 10 ppm (2 to 10 usual) (hawsepiper-book ch07) Maker/company setting; no primary source.
Galley and Laundry: The Calls the Crew SeesChecked · 3 confirmed · 0 corrected · 0 not verified
confirmed: 150 ohm elements on 440 V: series 300 ohm 1.47 A, one 2.93 A, parallel 75 ohm 5.87 A (Arithmetic re-computed by the auditor)
confirmed: 26 ohm heater on 220 V is about 1.9 kW (Arithmetic re-computed by the auditor)
confirmed: 12 kohm leak gives about 10 mA, twice the GFCI trip (5 mA) (IAEI on UL 943 Class A https://iaeimagazine.org/electrical-fundamentals/ground-fault-circuit-interrupter-gfci-protection/) Class A trips at 6 mA or more and must not trip under 4 mA; 5 mA nominal. 120/|12k - j2.95k| = 9.7 mA.
Gauges to DiagnosisChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: Saturation tables for six refrigerants (Honeywell Genetron / Arkema Forane PT charts (see pt-chart)) Table byte-identical to pt-chart.
unverified: Refrigerant work needs EPA Section 608 certification (40 CFR 82.161 (not fetched)) Well-established rule; text not fetched.
confirmed: Superheat = suction line temperature minus dew point; subcooling = bubble point minus liquid line temperature; normal bands superheat 4-9 K, subcooling 2-7 K (arithmetic / code read) Formulas right. Bands are labeled typical and not source-checked.
Generator ProtectionChecked in part · 2 confirmed · 0 corrected · 3 not verified
confirmed: ANSI device numbers: 32 reverse power, 40 loss of excitation, 51 time overcurrent, 50 instantaneous, 81U underfrequency, 46 phase unbalance, 59 overvoltage, 27 undervoltage, 86 lockout (GE Multilin ANSI device number reference, https://gevernova.com/grid-solutions/multilin/notes/ref/ansi.pdf) 27, 32 (directional power), 40, 46, 50, 51, 59, 81U and 86 all match
unverified: IEC standard inverse curve t = TMS x 0.14 / ((I/Is)^0.02 - 1) (IEC 60255-151 not fetched)
unverified: Reverse power 'typically a few percent of rating'; here 27 kW (3%) for 2 s (No class figure found (also noted in notes/for-justin-to-check.md line 132)) Conflicts with the Hawsepiper book, which gives 5-15% for diesel sets (ch01_electrical, switchboards_breakers). The ship's 3% is below the book's own range. Not changed: no primary source
confirmed: 130% = about 1,900 A; 8 x FLC = 11,800 A; 1.6 x = 2,360 A; 150% = 2,210 A; 5 x = 7,380 A; 10 x = 14,760 A (arithmetic checked by hand)
unverified: Grading margin typically 0.2 to 0.4 s (no primary source reached this session; not changed)
Glossary Flash CardsChecked in part · 2 confirmed · 0 corrected · 3 not verified
confirmed: Hours of rest: 10 hours in any 24 and 77 in any 7 days, recorded per person (USCG policy letter STCW Hours of Rest, https://www.dco.uscg.mil/Portals/9/TVNCOE/Documents/PolicyLetters/STCWHours_of_Rest.pdf)
confirmed: 15 ppm monitor / OWS under 15 ppm (https://www.law.cornell.edu/cfr/text/33/151.10)
unverified: Surface prep grade: ISO 8501-1 St 2 hand tool, St 3 power tool, Sa 2 1/2 near-white blast (https://steelconstruction.info/Surface_preparation) WRONG IN THE BOOK GLOSSARY (not edited): ISO 8501-1 St 2 is 'thorough hand and power tool cleaning' and St 3 'very thorough hand and power tool cleaning'; the hand/power split is SSPC SP 2 / SP 3. Sa 2 1/2 is 'very thorough blast cleaning'. Reported as book erratum.
unverified: Starting air about 25 to 30 bar; ECA 0.10% sulfur; VLSFO 0.50%; ULSFO 0.10%; MARPOL Annex I oil, IV sewage, V garbage, VI air (MARPOL (not fetched)) Read and no error suspected; not source-checked.
unverified: About 65 other number-bearing definitions read across 0-9 and A-W (NAMUR NE43 3.6/21 mA, bearing bore code, bolt property class, ISO 14726 colors, relay 11/12/14, flare 45/37 degrees, LEL under 1% for entry, PI 2 / 1.5, overspeed 110-115%, recovery cylinder 80%, SAE grade 8, micrometer thimble, wire rope 10 in a lay / 5 in a strand, thermal growth 0.012 mm/m/C, UNC/UNF, etc.) Read for errors; none suspected apart from the ISO 8501-1 entry. Not checked one by one against primary sources.
GMDSS: The Station, the Radios, the BatteriesChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: VHF DSC is on channel 70 (47 CFR 80.1085(a)(1)(i) https://www.law.cornell.edu/cfr/text/47/80.1085)
confirmed: Reserve battery on the bus carries the station when ship's power is lost (reserve source of energy) (SOLAS IV/13 as mirrored in 47 CFR 80.1099 and USCG NAVCEN https://www.navcen.uscg.gov/node/229) 1 hour with an emergency generator, 6 hours without; the page gives no hours, which is consistent.
confirmed: 27.2 V is 13.6 V a block; 6 A for 1 h = 6 Ah; 6 A from 0125 to 0150 is about 2.5 Ah; 9.0 A charger = 6.0 + 3.0 (Arithmetic re-computed by the auditor)
unverified: EPIRB floats free and alerts by satellite; SARTs answer a searching radar; survival craft VHFs carry a sealed distress battery with an expiry date; an accidental distress alert must be canceled at once (SOLAS IV/7, III/6 (not fetched)) Standard GMDSS facts; no text fetched.
confirmed: 3% droop: dial 30, no-load 61.8 Hz, full load lands on 60 Hz (arithmetic (model: speed = set - droop x rack)) 61.8/60 - 0.03 = 1.000. Overspeed trip in the model at 69 Hz = 115%; underfrequency at 56.5 Hz; both teaching values.
confirmed: Ungrounded 440 V: healthy lamps see 254 V; a solid ground puts the other two phases 440 V above the hull; megger at 500 V (arithmetic checked by hand; megger voltage per IEEE 43 summary (secondary))
confirmed: Three ground lamps share 440 V: about 254 V each (arithmetic checked)
confirmed: Megger 500 V for motor windings and lifted cables; never on electronics (https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums (summarizes IEEE 43; secondary)) Test voltage per IEEE 43; the electronics rule is practice.
Ground Lamps and the Ground HuntChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: Phase to hull about 254 V healthy; grounded phase lamp dark, other two at 440 V (arithmetic re-worked) 440/1.732 = 254.
confirmed: On shore power the monitor reads the pier's grounded neutral (physics; consistent with shore-power lesson)
confirmed: Leakage clamp: 410 mA against 19-44 mA (arithmetic re-worked) Teaching values; self-consistent with ungrounded-system lesson (0.41 A).
unverified: Hunt order: which island, then feeders one at a time, panel, circuit; nav lights and bridge supply not dropped without the mate; leakage clamp where a feeder cannot be dropped (book practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Ground, Short or Open: Which Do You Have?Checked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: Megger at 500 V for grounds on 440 V motors and cables (IEEE 43-2013 via two secondary summaries (primary text paywalled): https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums ; https://reliamag.com/articles/insulation-testing-ieee-standards-43-and-p97/)
confirmed: Loop of 30 m of 1.5 mm2 about 0.4 ohm (arithmetic re-worked) About 12.1 mohm/m x 30 m = 0.36 ohm plus leads.
unverified: Symptom picks the test: ohms between conductors for a short, megger to hull for a ground on motors and cables, continuity for an open; isolated, locked out and proved dead first (book practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Gyro, Autopilot and Steering: One LoopChecked in part · 1 confirmed · 0 corrected · 3 not verified
confirmed: Rudder moves at about 2.3 degrees a second (46 CFR 58.25-10(c)(2), https://www.law.cornell.edu/cfr/text/46/58.25-10) 35 one side to 30 the other in 28 s = 65 / 28 = 2.32 degrees a second (same as SOLAS II-1/29.3.2).
unverified: Gyro speed error = speed x cos(course) / (900 knots x cos(latitude)) radians; 15 kn, 350, 27 N gives 1.05 degrees; under 0.1 on 085 (https://marinegyaan.com/?p=15136 and https://knowledgeofsea.com/?p=6061 (secondary); arithmetic recomputed) Two secondary sources confirm the behavior: the error depends on the north-south part of the speed (V cos course), grows with latitude, is greatest on north-south courses and nil on east-west. Neither gives the constant in text (one shows the formula only as an image); Bowditch was not found to carry it. The 900 knots is 21,600 nautical miles in 24 hours. The lesson's numbers follow from its formula.
unverified: No. 1 steering pump on the main board, No. 2 on the emergency board (SOLAS II-1/30 (not fetched)) Ship layout; not changed.
unverified: A gyro takes hours to settle after power returns (gyro makers' manuals) Not changed.
confirmed: Torque for the same tension: dry 1, oiled about ¾, moly about ½ (https://crafter.fastenal.com/static-assets/pdfs/Torque-Tension_Chart_for_A307_Gr5_Gr8_Gr9.pdf) Fastenal K 0.20 dry vs 0.15 lubricated = 0.75; moly figure not checked.
unverified: TIR = highest - lowest; coupling hub run-out limit typically 0.05 mm (maker's figure governs; not fetched)
How Distribution BreaksChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: 235 A = 6.4 x plate; 12 V / 40 A = 0.3 ohm, 480 W; 220 x 440/462 = 209.5 V (arithmetic re-worked)
unverified: Do not re-close onto a trip with no load change; compare start current with the nameplate before touching a setting; never set above the drawing (book practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
How Motors BreakChecked · 5 confirmed · 0 corrected · 0 not verified
confirmed: Single-phased stall is about 0.87 x the 235 A direct start (arithmetic recomputed (sqrt3 / 2))
confirmed: Wye start is a third of the 390 A direct start, 130 A (arithmetic recomputed)
confirmed: Magnetic trip 4 x In on 100 A is 400 A; 3 x In on 40 A is 120 A; 160 A is about 6 x 26 A (arithmetic recomputed)
confirmed: Megger before a second start after a breaker trip; a stalled motor is held only a second or two (read in full on the second pass; procedure or ownership rule, no outside standard applies)
confirmed: Reverse a motor by two leads at the motor end, not at the board (read in full on the second pass; procedure or ownership rule, no outside standard applies)
HVAC and Provision Plant RepairsChecked in part · 5 confirmed · 0 corrected · 1 not verified
confirmed: Venting refrigerant is illegal, and the ban covers R-404A too (40 CFR 82.154(a)(1)-(2) https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F/section-82.154) 40 CFR part 82 is US law (Clean Air Act section 608): it binds US-flag ships and work done in US waters, not foreign-flag ships elsewhere. Rule bans knowingly venting 'any refrigerant' (only CO2, nitrogen, water, ammonia and some hydrocarbons exempt), so HFC R-404A is covered. De minimis releases during good-faith recovery are allowed. This is US law; the page does not say so.
confirmed: Part-winding: each winding and overload set at half the plate, 63 A of 126 A (Arithmetic re-computed by the auditor)
confirmed: 1650/1100 = 1.5 times speed, about 3.4 times the power (fan law, cube) (Arithmetic re-computed by the auditor)
confirmed: Pt1000 reads 930 ohm at -18 C (IEC 60751 Pt100 table (alpha 0.00385), as published at https://www.dwyeromega.com/de-de/resources/pt100-table/) 92.95 ohm x 10.
confirmed: LP 1.5 - 0.3 = 1.2 bar differential; gauge 0.2 high arithmetic (Arithmetic re-computed by the auditor)
unverified: Contactor rated 80 A AC-1 is only 50 A AC-3 (IEC 60947-4-1 utilization categories (not fetched)) Concept is right; the 80/50 pair is a teaching value.
ICCP, Shaft Grounding and Marine Growth PreventionChecked in part · 3 confirmed · 1 corrected · 2 not verified
confirmed: Protected band on a zinc reference is 0 to +250 mV (ABS Guidance Notes on Cathodic Protection of Ships (Dec 2017), Table 2 and criteria https://ww2.eagle.org/content/dam/eagle/rules-and-guides/current/conventional_ocean_service/289_cathodicprotectionofships_2017/cathodic-protection-gn-dec17.pdf) ABS: -0.80 V Ag/AgCl = +244 mV on zinc; over-protection limit -1.10 V Ag/AgCl is about -0.06 V on zinc, so 0 is a slightly cautious lower edge.
unverified: Freely corroding steel reads about +400 mV on zinc (Derived: steel about -0.60 to -0.65 V Ag/AgCl, zinc about -1.04 V Ag/AgCl) ABS document gave no free-corrosion figure; the derivation agrees (+390 to +440 mV).
confirmed: Over-protection: hydrogen at the steel and coating damage, worst near the anodes; dielectric shield round the anode (ABS Guidance Notes on Cathodic Protection of Ships (Dec 2017), Table 2 and criteria https://ww2.eagle.org/content/dam/eagle/rules-and-guides/current/conventional_ocean_service/289_cathodicprotectionofships_2017/cathodic-protection-gn-dec17.pdf)
confirmed: Shaft-to-hull meter should read under about 50 mV; over that, inspect brushes and ring (Althen shaft grounding manual https://www.althensensors.com/uploads/products/datasheets/manual-propeller-shaft-earthing-system-althen-sensors.pdf ; also https://www.marineinsight.com/tech/how-spark-erosion-can-damage-the-main-propulsion-engine-of-a-ship/)
corrected: 'MAN says inspect the brushes above 50 mV' (Althen shaft grounding manual (50 mV) https://www.althensensors.com/uploads/products/datasheets/manual-propeller-shaft-earthing-system-althen-sensors.pdf) Attribution to MAN could not be verified, so it was dropped (answer text and source comment). The 50 mV figure stays. Rebuilt, chk and walk clean.
unverified: ICCP off and locked out whenever divers are in the water (US Navy Diving Manual ship repair checklist https://navydiving.tpub.com/NavyDiving/css/Dive_Man_ChangeA_149.htm ; ICorr marine CP safety Q&A https://www.icorr.org/wp-content/uploads/2021/06/2021-01-19-ICorr-MCF-19-01-2021-QA-_-Marine-CP-Safety-Dr-Pat-Lydon.pdf) The page's rule is stricter than the sources found: the Navy manual requires ICCP off, tagged and confirmed only when divers work on or near an ICCP anode, shield or reference cell, and leaves it on otherwise; the ICorr Q&A says the operator decides. No ICCP maker's manual was reachable (Scribd only). Left as written because it errs on the safe side.
confirmed: Healthy card recomputed from the page's model: P comp 144 bar, P max 179 bar at 6 deg ATDC, MIP 18.8 bar, 2,238 kW per unit (13.4 MW for six) at 600 x 2,400 mm, 105 rpm (arithmetic (model ported and rerun)) kW = MIP x 1e5 x swept volume x rpm/60/1000 is right for a two-stroke. Labeled illustrative.
confirmed: 37 / 0.93 = 39.8 kW; 1.732 x 440 x 61 x 0.86 = 40 kW; 61 x 1.15 = 70.2 A; 61 / 1.732 = 35.2 A; 60 Hz motor on 50 Hz runs 17% slower; 1 HP = 0.746 kW (arithmetic checked by hand)
confirmed: NEMA code letter G = 5.6 to 6.3 kVA per HP (https://petrowiki.spe.org/Motor_specifications (quotes NEMA MG 1: code G = 5.6 to 6.29 kVA/hp; secondary))
confirmed: Insulation class B 130 C, F 155 C, H 180 C (https://weh.maritime.edu/EN-3111/references/nema-standards-for-electric-motors.pdf (motor maker reference sheet)) B 130 C, F 155 C, H 180 C maximum winding temperature
confirmed: Single-phasing: current in the two remaining lines up about 1.7 times (circuit theory (root 3))
unverified: Overload: set to nameplate FLA; with S.F. 1.15, FLA x 1.15 at most (no primary source reached this session; not changed) Conservative against NEC 430.32 (125%); the page tells the reader to follow the ship's drawings
Isolate a Loop Fault, Swap a Detector or Call PointChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: Section metered with a multimeter, not a 500 V megger, with devices connected (Book rule (ETO 7.6); consistent with detector makers' instructions) No regulation involved.
unverified: Disabled section means patrols and a log entry until restored (SOLAS II-2/7 and ISM practice (not fetched)) Sound practice; no primary text fetched.
Keeping the Drawings TrueChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: Red-line the day of the change, dated and initialed, into the master before leaving; tag and log temporary jumpers (book practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
confirmed: Engine rated in kW, alternator in kVA; governors split kW, AVRs split kVAR; a set can reach its ammeter limit with kW to spare (arithmetic re-worked)
Ladder LogicChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: Floats pump a cargo hold bilge automatically, never an engine room bilge (site rule set by Justin (common.md)) House rule, not checked against MARPOL/class text
Lighting: Ballasts, LED Drivers and Wet FittingsChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: 120 x 7 uA = 0.84 mA; 220 V / 0.84 mA = 262 kohm (arithmetic re-worked)
unverified: A switch is not isolation on an ungrounded 220 V circuit (both lines live); work aloft needs a permit, harness and the radar off and tagged (practice; COSWP-type rule not fetched) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Line It Up: Fuel OilChecked in part · 0 confirmed · 0 corrected · 2 not verified
unverified: Fuel oil is brown on pipe color codes (ISO 14726 (not fetched)) Matches the book glossary; ISO text not fetched.
unverified: Heat VLSFO to about 98 C for the separator (Alfa Laval separator manuals) The Alfa Laval P-separator leaflet fetched says only 'correct temperature'. 98 C is the usual maker figure for residual fuel.
confirmed: Below about 3.6 mA or above about 21 mA is a failure (NAMUR NE 43) (NAMUR NE 43 as summarized at https://www.electricalvolt.com/what-is-namur-ne-43 (secondary; NE 43 itself is paywalled))
confirmed: 250 ohm turns 4-20 mA into 1-5 V; +/-0.5% of span = +/-0.08 mA; scaling examples (arithmetic checked by hand)
Lubricants and Greases: The Right One, the Right AmountChecked in part · 3 confirmed · 0 corrected · 4 not verified
confirmed: Grease quantity grams = 0.005 x outside diameter x width; 6311 (120 x 29) = 17.4 g (https://www.machinerylubrication.com/Articles/Print/903?id=903 (attributes Gp = 0.005·D·B to SKF; secondary) ; https://www.qualitybearingsonline.ca/6311-skf-deep-groove-bearing-55-x-120-x-29mm)
confirmed: 17 g at 1.5 g a stroke = about 11 strokes (arithmetic checked)
confirmed: VLSFO 0.50 % S: cylinder oil BN 40; ULSFO 0.10 %: BN 40 or 15-25 where the maker allows (https://man-es.com/docs/default-source/service-letters/sl2019-671.pdf (MAN ES SL2019-671)) MAN SL2019-671: VLSFO start with 40 BN; ULSFO start with 15-25 BN (up to 100 on cylinder condition). Maker's current letter governs.
unverified: BN in service not below half of fresh (engine makers' guidance; not fetched)
unverified: Injector test bench oil: ISO 4113 calibration fluid (ISO 4113; not fetched)
unverified: Polyurea and lithium complex greases usually incompatible (grease compatibility charts disagree (the page says so))
Make a Bronze Bushing on the LatheChecked in part · 4 confirmed · 0 corrected · 1 not verified
confirmed: rpm ≈ 318 x v ÷ d; 60 m/min on 55 mm = 347 rpm; 350 rpm = 61, 560 = 97, 140 = 24, 900 = 155 m/min (arithmetic checked)
unverified: Leaded bronze/brass HSS 45-90 m/min, 0° top rake; mild steel 8-15° rake (Machinery's Handbook not reachable)
confirmed: Press fit 0.001 x diameter (50 mm = 0.05); running clearance 0.001-0.0015 x shaft (35 mm = 0.035-0.0525) (arithmetic checked) Rules of thumb are the book's; arithmetic checked.
Make Up a Cable End and GlandChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: Seal on the outer sheath, braid dressed all round into the cone, ferrule on every stranded core, numbers on, slack to re-terminate once (book practice; gland makers' instructions not fetched) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Megger a Motor and Dry It OutChecked in part · 6 confirmed · 0 corrected · 4 not verified
confirmed: 500 V DC megger test on a 440 V motor (IEEE 43 values as quoted at https://electrical-engineering-portal.com/measurement-of-insulation-resistance-2 and https://wiki.testguy.net/t/field-testing-of-motors/249 (two secondary sources; IEEE text is paywalled))
confirmed: Old rule 1 megohm per kV + 1, about 1.5 megohm at 450 V (IEEE 43 values as quoted at https://electrical-engineering-portal.com/measurement-of-insulation-resistance-2 and https://wiki.testguy.net/t/field-testing-of-motors/249 (two secondary sources; IEEE text is paywalled)) 0.45 + 1 = 1.45
confirmed: IEEE 43 asks 5 megohm of a modern low-voltage winding (IEEE 43 values as quoted at https://electrical-engineering-portal.com/measurement-of-insulation-resistance-2 and https://wiki.testguy.net/t/field-testing-of-motors/249 (two secondary sources; IEEE text is paywalled))
unverified: Read at one minute and log the temperature (IEEE 43 (not reached in full text)) Standard practice; the sources reached did not quote the one-minute clause.
unverified: Hold frame under about 80 C while drying (ABB Standard LV Motors Manual (2009 Rev D), https://library.e.abb.com/public/e20ddd6a89ed4815821e8163f569bf63/Standard_LV_Motors_Manual_EN_01_2009%20Rev%20D.pdf) ABB dries damp windings in an oven at 90 C for 12-16 h, then 105 C for 6-8 h, with drain plugs out. The book's 'frame under about 80 C' is lower, so it is on the safe side; no source gives 80 C itself. ABB also says windings drenched in sea water normally need to be rewound: the lesson's emergency fire pump is wet from sea water dripping through a vent and is dried, not rewound. For Justin to consider.
unverified: Never megger through a VFD: disconnect the drive (maker practice) Universal maker instruction, no single primary document fetched.
confirmed: Discharge the winding to the frame after a megger test (ABB Standard LV Motors Manual (2009 Rev D), https://library.e.abb.com/public/e20ddd6a89ed4815821e8163f569bf63/Standard_LV_Motors_Manual_EN_01_2009%20Rev%20D.pdf) ABB: discharge windings against the frame immediately after each measurement.
unverified: Two megohms is the floor (ABB Standard LV Motors Manual (2009 Rev D), https://library.e.abb.com/public/e20ddd6a89ed4815821e8163f569bf63/Standard_LV_Motors_Manual_EN_01_2009%20Rev%20D.pdf; IEEE 43 (5 megohm)) Book figure. ABB's reference for its own motors is 100 megohm corrected to 25 C (500 or 1,000 V DC); IEEE 43 gives 5 megohm. The lesson already tells the reader to use the ship's figure if higher.
confirmed: Reading moves with temperature, so log the temperature (ABB Standard LV Motors Manual (2009 Rev D), https://library.e.abb.com/public/e20ddd6a89ed4815821e8163f569bf63/Standard_LV_Motors_Manual_EN_01_2009%20Rev%20D.pdf) ABB: insulation resistance halves for each 20 C rise.
confirmed: Order: isolate, lock out and tag, prove the tester, prove dead; megger the motor alone with leads lifted (read in full on the second pass; procedure or ownership rule, no outside standard applies)
Motor ControllersChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: 22 kW 440 V motor, 37 A plate, 40 A AC-3 contactor, 63 A breaker (arithmetic checked) 22 kW/(1.732 x 440 x ~0.86 pf x ~0.91 eff) = about 37 A.
unverified: Overload set to nameplate amps (times service factor where above 1.0) (NEC 430.32 allows up to 115-125 % of FLA depending on SF; not fetched) Page's rule is the conservative one.
confirmed: Swapping any two phases reverses a three-phase motor (physics)
One Fault at a Time, and the Second One Water MakesChecked · 2 confirmed · 0 corrected · 0 not verified
confirmed: 3 kilohm in series with a 60 ohm coil on 110 V: 107.8 V across the terminal, 2.2 V on the coil (arithmetic recomputed)
confirmed: A wet lighting circuit is read with a multimeter on ohms to hull; the megger is for motor windings (notes/for-justin-to-check.md, settled by Justin 2026-11-11) Ship rule set by Justin, not an outside standard.
Parallel the GeneratorsChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: 900 kW at 0.8 pf = 1,125 kVA = 1,476 A at 440 V (arithmetic checked by hand) 1,125,000/(1.732x440)=1,476
confirmed: Reverse power trip 27 kW = 3% of 900 kW (arithmetic checked by hand) Teaching setting; see protective-relays note on the 3% figure
unverified: Match voltage, run incoming slightly fast, close just before 12 o'clock (no primary source reached this session; not changed) Standard practice and matches ETO 2.3; no standard cited
Phase Rotation: Prove It, Swap It at the MotorChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: LT2 0.9 of 2.2 bar is about 40 percent of head (Arithmetic re-computed by the auditor)
unverified: Six-lead wye-delta motor: to reverse, swap U1 with V1 and U2 with V2 (IEC 60034-8 terminal markings (not fetched)) Electrically correct; standard not fetched.
PID TuningChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: P alone leaves an offset; shorter integral time = stronger action; hand-tuning recipe (no primary source reached this session; not changed) Control theory and a rule of thumb, no standard
PID: Controller or Valve?Checked in part · 0 confirmed · 2 corrected · 1 not verified
corrected: 1.3 C high x 5 %/C = 6.7 % (arithmetic re-worked) 1.3 x 5 = 6.5. The model's offset is 1.33 C, so the text now reads 1.33 C x 5 %/C = 6.7 %. Rebuilt; chk.py clean.
corrected: Derivative 'is little used on temperature loops because it also pushes on noise' (ISA: https://blog.isa.org/when-and-how-to-use-derivative-action-in-a-pid-controller ; Control Station: https://controlstation.com/derivative-affect-pid-controller-performance/) Sources say the reverse about temperature loops: derivative is the least used mode overall because of noise, and slow temperature loops are where it suits. Text now: 'It is the least used of the three because it also pushes on noise; a slow temperature loop like this one is where it fits best.' Rebuilt; chk.py clean.
unverified: Flat-jump-flat trend is a sticking valve; tuning is the Chief's or the vendor's; ETO records as-found settings and does not change them (book practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Pipe Work: Prove It Dead, Clamp It, Renew ItChecked in part · 3 confirmed · 0 corrected · 3 not verified
confirmed: Hydrotest 1.5 x design: 6 bar design = 9 bar (arithmetic checked) 1.5 x is the usual class/ASME B31 figure; class procedure overrides (page says so).
confirmed: Gauge middle third: 5.3 to 10.7 bar on a 16 bar gauge (arithmetic checked)
confirmed: NPT and BSPT share the thread count at ½ and ¾ in (https://en.wikipedia.org/wiki/British_Standard_Pipe (BS EN ISO 228 figures; secondary))
unverified: PTFE 2-4 wraps, hand-tight then 2-3 wrench turns; fitting goes on 4-5 turns by hand (ASME B1.20.1 hand-tight engagement not fetched)
Piping, Flanges and GasketsChecked in part · 5 confirmed · 0 corrected · 3 not verified
confirmed: DN100 bolt circles: JIS 5K 165, JIS 10K 175, PN16 180, ANSI 150 190.5 mm; all eight bolts (https://prashaantsteel.com/jis-b2220-flanges-standards-dimensions/ ; https://www.wermac.org/societies/jis_flg_dim_5k.html ; https://valvesonline.com.au/references/flange-tables) JIS B2220 5K 100A 200/165/8x19; 10K 210/175/8x19; PN16 220/180/8x18; ASME B16.5 Class 150 229/191(190.5)/8.
confirmed: ISO 14726 bands: green sea water, brown fuel, silver steam, red fire-fighting, orange other oils; second color = sub-system/medium (https://law.resource.org/pub/us/cfr/ibr/inc/iso/iso.14726.2008.pdf (ISO 14726:2008 Table 2))
confirmed: Steel grows about 1.2 mm per meter per 100 °C; 10 m x 150 °C = 18 mm (arithmetic checked) Coefficient 12e-6/K is the handbook value (not fetched).
confirmed: DN300 bellows at 3 bar pushes about 20 kN (arithmetic checked) 0.0707 m² x 300 kPa = 21 kN.
unverified: 8-bolt star 1-5-3-7-2-6-4-8; passes 30/60/100 % then a check round (ASME PCC-1 not fetched) Matches the usual legacy cross pattern.
unverified: Sea water in Cu-Ni wants 3 m/s or less (Copper Development Association guidance not fetched)
confirmed: NPT on BSPT starts then leaks; BSPP seals on a washer or O-ring (https://en.wikipedia.org/wiki/British_Standard_Pipe (BS EN ISO 228 figures; secondary))
unverified: EPDM for water, never on oil; NBR for oil (elastomer compatibility charts not fetched)
Plant Tour: Ballast and Ballast Water TreatmentChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: D-2: under 10 viable organisms per m3 at 50 um and over (BWM Convention reg D-2 and B-2, IMO: https://www.imo.org/en/mediacentre/hottopics/pages/implementing-the-bwm-convention.aspx) D-2 also limits 10-50 um organisms and three indicator microbes; page gives only the first line.
confirmed: Every uptake and discharge goes in the Ballast Water Record Book (BWM Convention reg D-2 and B-2, IMO: https://www.imo.org/en/mediacentre/hottopics/pages/implementing-the-bwm-convention.aspx)
unverified: TRO discharge limit commonly 0.1 mg/L per the certificate Typical type-approval figure; no primary text fetched. Page says 'commonly'.
Plant Tour: Bilge, Oily Water Separator, Sludge and IncineratorChecked in part · 8 confirmed · 0 corrected · 1 not verified
confirmed: Discharge only under 15 ppm; over 15 ppm the three-way valve returns flow to the holding tank (MEPC.107(49) 4.2.9 via Transport Malta MS Notice 155: https://www.transport.gov.mt/maritime/merchant-shipping-notices/ms-notice-155-marpol-related-deficiencies-to-the-15-ppm-bilge-alarm-system-3309) MARPOL Annex I reg 14/15 with MEPC.107(49).
confirmed: Monitor logs date, time, alarm and valve position, and keeps 18 months (MEPC.107(49) 4.2.9 via Transport Malta MS Notice 155: https://www.transport.gov.mt/maritime/merchant-shipping-notices/ms-notice-155-marpol-related-deficiencies-to-the-15-ppm-bilge-alarm-system-3309) Text says date, time, alarm status and operating status of the separator; 18 months. 'Valve position' is loose wording, not changed.
confirmed: Monitor calibration: maker's interval, certificate on board, never over 5 years (MEPC.285(70) amending MEPC.107(49) 4.2.11: https://www.irclass.org/media/6952/mepc285-70.pdf)
confirmed: ORB Part I codes C, D, E, F, G, H, I as described (MARPOL Annex I reg 17 and App. III, as printed in AMSA Oil Record Book Part I: https://www.amsa.gov.au/sites/default/files/2023-10/amsa-228_2023-oil-record-book-part-1.pdf ; Bahamas MN056) Part I also has A and B (fuel tank ballasting/cleaning), not mentioned; not wrong.
confirmed: Officer in charge signs each operation; master signs each completed page; kept three years after the last entry (MARPOL Annex I reg 17 and App. III, as printed in AMSA Oil Record Book Part I: https://www.amsa.gov.au/sites/default/files/2023-10/amsa-228_2023-oil-record-book-part-1.pdf ; Bahamas MN056)
confirmed: Bulk lube oil bunkering is an ORB Part I entry (code H) (also on Lube Oil tour) (MARPOL Annex I reg 17 and App. III, as printed in AMSA Oil Record Book Part I: https://www.amsa.gov.au/sites/default/files/2023-10/amsa-228_2023-oil-record-book-part-1.pdf ; Bahamas MN056)
confirmed: Emergency bilge suction used in a real flooding is an ORB entry under code G (MARPOL Annex I reg 17 and App. III, as printed in AMSA Oil Record Book Part I: https://www.amsa.gov.au/sites/default/files/2023-10/amsa-228_2023-oil-record-book-part-1.pdf ; Bahamas MN056) G = accidental or other exceptional discharges.
confirmed: Incinerator sludge cut-off 850 C on many units (MARPOL Annex VI (MEPC.176(58)): https://wwwcdn.imo.org/localresources/en/KnowledgeCentre/IndexofIMOResolutions/MEPCDocuments/MEPC.176(58).pdf ; reg 14 text: https://www.egcsa.com/regulatory/marpol-annex-vi-regulation-14/) Annex VI reg 16.9: no feed below 850 C on continuous-feed units.
unverified: Sludge tank rising faster than 2 % of fuel burned Rule of thumb from the book; no primary source.
Plant Tour: Compressed AirChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: Class wants starting air for 12 consecutive starts of a reversible engine, split between two receivers (Class rule (DNV-RU-SHIP Pt.4 Ch.6 Sec.5, same as IACS UR M61) as quoted at https://samkmoodle.samk.fi/mod/page/view.php?id=22193 (secondary)) 6 starts for non-reversible.
unverified: Each starting air branch has a bursting disc or flame arrestor (SOLAS II-1/34 (text not fetched))
Plant Tour: Fire ProtectionChecked in part · 13 confirmed · 0 corrected · 2 not verified
confirmed: Emergency fire pump: at least 40 % of total required fire pump capacity, never under 25 m3/h (FSS Code ch. 2, 5, 12 (full-text mirror: https://meoexamsmmd.blogspot.com/2021/06/fss-code.html; secondary, cross-checked with UK MCA SOLAS II-2 reg 10 guidance)) FSS ch.12 2.2.1.1; 25 m3/h applies to cargo ships of 2,000 GT and over (Hawsepiper is).
confirmed: Hydrant pressure at least 2.5-2.7 bar (SOLAS, by tonnage) (SOLAS II-2/10, UK MCA text: https://assets.publishing.service.gov.uk/media/5a7f91bde5274a2e8ab4cf90/Regulation_10_-_Fire-Fighting.pdf) Cargo ships: 0.27 N/mm2 at 6,000 GT and over, 0.25 below. Passenger ships are 0.30/0.40; page is a cargo ship.
confirmed: Hydrants placed so any part gets two jets, one from a single hose length (SOLAS II-2/10, UK MCA text: https://assets.publishing.service.gov.uk/media/5a7f91bde5274a2e8ab4cf90/Regulation_10_-_Fire-Fighting.pdf) II-2/10.2.1.5.1; jets from different hydrants.
confirmed: Each main fire pump able to put two jets on the main (SOLAS II-2/10, UK MCA text: https://assets.publishing.service.gov.uk/media/5a7f91bde5274a2e8ab4cf90/Regulation_10_-_Fire-Fighting.pdf) II-2/10.2.2.4.2
confirmed: Isolation valve between engine room section and deck is outside the engine room so the emergency pump can feed the deck (SOLAS II-2/10, UK MCA text: https://assets.publishing.service.gov.uk/media/5a7f91bde5274a2e8ab4cf90/Regulation_10_-_Fire-Fighting.pdf) II-2/10.2.1.4.1
confirmed: Emergency fire pump outside the engine room with its own sea suction and power source (SOLAS II-2/10, UK MCA text: https://assets.publishing.service.gov.uk/media/5a7f91bde5274a2e8ab4cf90/Regulation_10_-_Fire-Fighting.pdf) II-2/10.2.2.3.1.2
confirmed: International shore connection: standard flange, gasket and four bolts (FSS Code ch. 2, 5, 12 (full-text mirror: https://meoexamsmmd.blogspot.com/2021/06/fss-code.html; secondary, cross-checked with UK MCA SOLAS II-2 reg 10 guidance)) FSS ch.2: 4 bolts 16 mm x 50 mm, 4 nuts, 8 washers, gasket.
confirmed: CO2: 40 % of the volume; 85 % in 2 min or less (FSS Code ch. 2, 5, 12 (full-text mirror: https://meoexamsmmd.blogspot.com/2021/06/fss-code.html; secondary, cross-checked with UK MCA SOLAS II-2 reg 10 guidance)) FSS ch.5 2.2.1.2 (40 % of gross volume excluding casing, or 35 % including it) and 2.2.1.5.
confirmed: CO2 release takes two separate actions: distribution valve for the space, then the bank; key in a break-glass box; opening the cabinet starts the pre-discharge alarm (FSS Code ch. 2, 5, 12 (full-text mirror: https://meoexamsmmd.blogspot.com/2021/06/fss-code.html; secondary, cross-checked with UK MCA SOLAS II-2 reg 10 guidance)) FSS ch.5 2.2.2 and 2.1.3.2. 'Stops the ventilation' on door opening is usual design, not checked against a rule text.
confirmed: CO2 cylinders: recharge below 90 % of charge (MSC.1/Circ.1318 s.6.1 (HK Marine Dept copy): https://www.mardep.gov.hk/en/msnote/pdf/msin2136anx1.pdf) Note MSC.1/Circ.1432 uses 95 % for other gas systems; 90 % is right for CO2.
confirmed: CO2 cylinder 45 kg in 67.5 L; 80 x 45 kg bank (arithmetic) 0.667 kg/L fill ratio; 3,600 kg x 0.56 m3/kg = 2,016 m3 = 40 % of a 5,040 m3 space. Self-consistent teaching values.
confirmed: Detectors: a sample monthly, every head within 5 years (MSC.1/Circ.1432 s.5 (Netherlands flag copy): https://puc.overheid.nl/nsi/doc/PUC_2195_14/3/)
confirmed: Fire pumps and EFP tested weekly (MSC.1/Circ.1432 s.5 (Netherlands flag copy): https://puc.overheid.nl/nsi/doc/PUC_2195_14/3/) IMO minimum is monthly; weekly is stricter ship practice and is not stated as the rule.
unverified: Quick-closing valve: shut only with the lever at least 3/4 of its travel Could not find a source; left alone. Looks like a book/maker figure.
unverified: Engine room may only be unattended with fire detection working (SOLAS II-1 Part E (text not fetched)) Standard UMS condition; not checked against the regulation text.
Plant Tour: HydraulicsChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: Hydraulic oil lost over the side from deck machinery is an oil discharge under MARPOL (MARPOL Annex I reg 1, 15 (not fetched)) General statement; not checked.
Plant Tour: Refrigeration and HVACChecked · 2 confirmed · 0 corrected · 0 not verified
confirmed: Refrigerant is recovered, never vented, and every leak check and addition is logged (MARPOL Annex VI (MEPC.176(58)): https://wwwcdn.imo.org/localresources/en/KnowledgeCentre/IndexofIMOResolutions/MEPCDocuments/MEPC.176(58).pdf ; reg 14 text: https://www.egcsa.com/regulatory/marpol-annex-vi-regulation-14/) Annex VI reg 12 requires the record book for ozone-depleting substances only; R-404A and R-134a are HFCs, covered by flag rules (US: EPA Section 608, not fetched). Good practice either way.
confirmed: R-404A suction about 1.2 bar and head 16-17 bar for a -18 C room on 25 C sea water (arithmetic / PT relationship) Consistent with R-404A saturation near -27 C and 35-38 C.
Plant Tour: Seawater and Central CoolingChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: Sea inlet valves must be easy to reach and show open or shut (SOLAS II-1) (SOLAS II-1/15, 48 (text not reached)) Could not reach the regulation text.
Plant Tour: Sewage and Gray WaterChecked in part · 2 confirmed · 0 corrected · 2 not verified
confirmed: Annex IV: plant effluent anywhere if no visible solids or discoloration; comminuted and disinfected beyond 3 nm; untreated or from a holding tank beyond 12 nm at a moderate rate, en route at 4 knots or more (MARPOL Annex IV reg 11 via Bahamas MN059: https://www.bahamasmaritime.com/wp-content/uploads/2022/02/MN059-MARPOL-Annex-IV-Sewage-Pollution-Prevention-v1.1.pdf) Does not mention the Baltic special area (passenger ships only).
confirmed: Residual chlorine: IMO guideline under 0.5 mg/L (MARPOL Annex IV reg 11 via Bahamas MN059: https://www.bahamasmaritime.com/wp-content/uploads/2022/02/MN059-MARPOL-Annex-IV-Sewage-Pollution-Prevention-v1.1.pdf) MEPC.227(64) figure as cited by Bahamas MN059.
unverified: Annex V cooking oil: landed or incinerated, logged in the Garbage Record Book (MARPOL Annex V reg 4, 10 (not fetched)) Believed right; text not reached today.
unverified: US no-discharge zones allow no sewage discharge (33 CFR 159 / 40 CFR 140 (not fetched))
confirmed: Emergency supply for rudder stock over 230 mm: automatic within 45 s, good for 30 min (SOLAS II-1/29 (summary mirror https://wordpress-sxaew.wasmer.app/?p=297) and II-1/30 as transposed in Canada Marine Machinery Regulations Sch. VII item 18: https://laws-lois.justice.gc.ca/eng/regulations/SOR-90-264/page-9.html (secondary; SOLAS text itself not reachable)) 30 min is for 10,000 GT and over (Hawsepiper 19,800 GT); 10 min below.
confirmed: 28 s hard-over (SOLAS II-1/29 (summary mirror https://wordpress-sxaew.wasmer.app/?p=297) and II-1/30 as transposed in Canada Marine Machinery Regulations Sch. VII item 18: https://laws-lois.justice.gc.ca/eng/regulations/SOR-90-264/page-9.html (secondary; SOLAS text itself not reachable)) 35 deg one side to 30 deg the other, at deepest draft and full speed.
confirmed: Relief valve not above design pressure; design at least 1.25 x max working pressure (SOLAS II-1/29 (summary mirror https://wordpress-sxaew.wasmer.app/?p=297) and II-1/30 as transposed in Canada Marine Machinery Regulations Sch. VII item 18: https://laws-lois.justice.gc.ca/eng/regulations/SOR-90-264/page-9.html (secondary; SOLAS text itself not reachable))
confirmed: Pumps restart by themselves when power returns (SOLAS II-1/29 (summary mirror https://wordpress-sxaew.wasmer.app/?p=297) and II-1/30 as transposed in Canada Marine Machinery Regulations Sch. VII item 18: https://laws-lois.justice.gc.ca/eng/regulations/SOR-90-264/page-9.html (secondary; SOLAS text itself not reachable))
confirmed: Overload never trips the motor: it is an alarm; alarms for power failure, overload, phase failure, low oil level (SOLAS II-1/29 (summary mirror https://wordpress-sxaew.wasmer.app/?p=297) and II-1/30 as transposed in Canada Marine Machinery Regulations Sch. VII item 18: https://laws-lois.justice.gc.ca/eng/regulations/SOR-90-264/page-9.html (secondary; SOLAS text itself not reachable)) Short-circuit protection plus overload alarm; phase-failure alarm on three-phase supplies.
confirmed: Steering gear tested within 12 hours before departure (SOLAS II-1/29 (summary mirror https://wordpress-sxaew.wasmer.app/?p=297) and II-1/30 as transposed in Canada Marine Machinery Regulations Sch. VII item 18: https://laws-lois.justice.gc.ca/eng/regulations/SOR-90-264/page-9.html (secondary; SOLAS text itself not reachable)) SOLAS V/26.
Plant Tour: The Electrical PlantChecked in part · 4 confirmed · 0 corrected · 3 not verified
confirmed: Emergency generator on the emergency board within 45 s (SOLAS II-1/43, 44 as quoted at https://samkmoodle.samk.fi/mod/page/view.php?id=22189 (secondary)) II-1/43.3.1.2
confirmed: EDG starting: three starts, and a second source for three more within 30 min (SOLAS II-1/43, 44 as quoted at https://samkmoodle.samk.fi/mod/page/view.php?id=22189 (secondary)) II-1/44.2
unverified: SOLAS wants at least two generating sets, sized so the ship runs with any one stopped (SOLAS II-1/41.1 (text not reached)) Believed right.
unverified: Reverse power 5-15 % of rated kW (46 CFR 111.12-11(d),(f): https://codes.findlaw.com/cfr/title-46-shipping/cfr-sect-46-111-12-11/) CFR requires the trip for paralleled sets but gives no figure; the range is class/maker practice.
unverified: Voltage limits +6/-10 % (396-466 V on 440); undervoltage release opens between 70 and 35 % (308-154 V) (IEC 60092 / class rules (not fetched)) Arithmetic is right. Standard class figures, not checked against a primary text today.
confirmed: 900 kW, 0.8 pf, 1,476 A; 50-85 % = 450-765 kW; 5-15 % = 45-135 kW; TR 197 A / 394 A; 1,010 A at 0.65 pf and 690 A at 0.95 pf for 500 kW; 26.4-27.6 V on 12 cells (arithmetic) All agree with P = 1.732 x V x I x pf at 440 V (transformer 150 kVA).
Plant Tour: The Freshwater PlantChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: Don't make water within 20 nautical miles of the coast, in port or in estuaries (UK MGN 525 (M+F) Amd 1: https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/445615/MGN_525_Amd_1.pdf) MGN 525: 'Twenty miles from land is generally considered to be a safe distance'. It is guidance, not a convention rule; the page calls it 'the rule'.
confirmed: Tank disinfection commonly 50 ppm chlorine for 4 hours (CDC Vessel Sanitation Program construction guidelines s.21.13.1: https://stacks.cdc.gov/view/cdc/56576/cdc_56576_DS1.pdf) CDC VSP: at least 50 mg/L for at least 4 hours. UK MGN 525 says 50 ppm for 12 hours at refit; page says 'commonly'.
confirmed: UV leaves no residual; distillate needs remineralising and disinfecting (UK MGN 525 (M+F) Amd 1: https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/445615/MGN_525_Amd_1.pdf)
unverified: Calorifier outlet 60 C or above, return above 50 C; flush shower heads monthly, taps in empty cabins weekly (UK MGN 525 (M+F) Amd 1: https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/445615/MGN_525_Amd_1.pdf) MGN 525 gives 60 C and a 15-50 C growth band, which agrees; the flushing intervals are ship practice (MGN says shower heads cleaned every 3 months).
Plant Tour: The Fuel PlantChecked in part · 2 confirmed · 0 corrected · 3 not verified
confirmed: Sulfur 0.50 % or less; 0.10 % or less in an ECA (MARPOL Annex VI (MEPC.176(58)): https://wwwcdn.imo.org/localresources/en/KnowledgeCentre/IndexofIMOResolutions/MEPCDocuments/MEPC.176(58).pdf ; reg 14 text: https://www.egcsa.com/regulatory/marpol-annex-vi-regulation-14/) Reg 14.1.3 and 14.4.3.
confirmed: MARPOL retained sample from the drip sampler; BDN states grade, quantity and properties (MARPOL Annex VI (MEPC.176(58)): https://wwwcdn.imo.org/localresources/en/KnowledgeCentre/IndexofIMOResolutions/MEPCDocuments/MEPC.176(58).pdf ; reg 14 text: https://www.egcsa.com/regulatory/marpol-annex-vi-regulation-14/) Reg 18: sample sealed and signed, kept at least 12 months; BDN kept 3 years.
unverified: Density limit 991 kg/m3 (1010 on Alcap-type purifiers) (ISO 8217 / maker data (not fetched)) Standard figures; not checked against a primary text today.
unverified: Injection viscosity 10-15 cSt (MAN), 13-17 cSt (WinGD); at least 2 cSt on MGO; changeover 2 C a minute (maker documents (not fetched))
unverified: Compatibility spot test graded 1-5; 1-2 mixes, 3 and up does not (ASTM D4740 (not fetched))
Plant Tour: The Lube Oil PlantChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: Waste oil and sludge disposal is an ORB Part I entry with receipt kept (MARPOL Annex I reg 17 and App. III, as printed in AMSA Oil Record Book Part I: https://www.amsa.gov.au/sites/default/files/2023-10/amsa-228_2023-oil-record-book-part-1.pdf ; Bahamas MN056) Code C.
unverified: Cylinder oil BN and feed rate figures (BN 40 on MAN advice, 0.6-1.2 g/kWh) (maker service letters (not fetched)) Maker figures; not safety-regulatory.
Plant Tour: The Main Engine as a LoopChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: MARPOL Annex VI: the NOx Technical File lists injection parts and settings; record every change (NOx Technical Code 2008 (not fetched)) Believed right (record book of engine parameters).
PLC ProgrammerChecked in part · 7 confirmed · 0 corrected · 2 not verified
confirmed: Siemens analog card: 4 mA = 0 counts, 20 mA = 27648 (https://industrialmonitordirect.com/blogs/knowledgebase/siemens-4-20ma-analog-input-overrange-and-wire-break-counts (secondary))
confirmed: A broken wire reads 32767 on the Siemens card (Siemens S7-1500 manual, analog value representation, Table C-21 via https://www.manualslib.com/manual/1298189/Siemens-Simatic-S7-1500.html?page=74) True with wire-break diagnostics enabled; with diagnostics off the card returns the underflow value instead
confirmed: 3.8 mA = -346 counts, 20.5 mA = 28512 counts; 16 mA = 20736; 14 mA = 62.5% (arithmetic checked by hand)
confirmed: Under 3.8 mA or over 20.5 mA the signal is BAD (NAMUR NE 43 as summarized at https://www.electricalvolt.com/what-is-namur-ne-43 (secondary; NE 43 itself is paywalled)) These are the NE 43 measuring-range limits; the Loop Check sim quotes the 3.6 / 21 mA failure levels. Both are right, worded differently
confirmed: INT range -32768 to 32767; 27648 x 100 overflows an INT (arithmetic checked by hand)
confirmed: Allen-Bradley names: OTL, OTU, TOF, CTU, CTD, RES, ONS, GEQ, LES, EQU, NEQ, GRT, LEQ, SCP; Siemens NORM_X + SCALE_X, P_TRIG, TP, LD and R inputs on counters, RT (Rockwell page above (TOF, CTU, CTD, RES) and https://industrialmonitordirect.com/blogs/knowledgebase/mapping-allen-bradley-instructions-to-siemens-s7-1200-equivalents (OTL/OTU = set/reset coils, GEQ LES EQU NEQ GRT LEQ, P_TRIG; secondary)) Not found in a source read: ONS, SCP, NORM_X/SCALE_X, RT, the LD input
unverified: Siemens and Allen-Bradley give a down counter's done bit different meanings (no primary source reached this session; not changed)
confirmed: Allen-Bradley Logix has no TP pulse timer (Rockwell Studio 5000 Logix Designer, Timer and Counter Instructions, https://rockwellautomation.com/en-us/docs/studio-5000-logix-designer/37-00/contents-ditamap/instruction-set/timer-and-counter-instructions.html) Ladder set is TON, TOF, RTO, CTU, CTD, RES
unverified: FORCE light: Siemens MAINT on newer CPUs, Allen-Bradley FORCE (no primary source reached this session; not changed)
PLC RackChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: PNP sensor needs a sinking input (common on 0 V); NPN needs a sourcing input (common on +24 V) (no primary source reached this session; not changed) Circuit logic is self-consistent; page warns makers use the words both ways
Preferential Trip and Load SheddingChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: 136 % on one set; stage 1 to 119 %, stage 2 to 83 %; 83 % + 360 kW = 123 % (arithmetic re-worked) 1,224 kW total.
confirmed: Overcurrent pickup 110 % (46 CFR 111.12-11: https://codes.findlaw.com/cfr/title-46-shipping/cfr-sect-46-111-12-11/) Within the 115 % limit.
unverified: Stages at 100 % for 4, 8, 12 s (none) Teaching settings. Rules require non-essential load shedding but give no times.
confirmed: Never wire the preferential trip out; essentials never shed; restore capacity first, then close shed feeders one at a time (UK MCA survey instructions 7.6 (load shedding must not interfere with essential services): https://assets.publishing.service.gov.uk/media/5a7c6454ed915d696ccfc775/con1_2a_pt7_1-2.pdf) Rule supports 'essentials never shed'; the rest is practice.
Protective Relays: Read the FlagChecked in part · 4 confirmed · 0 corrected · 2 not verified
unverified: Reverse power set 27 kW (3 % of 900 kW) for 2 s on a diesel set (46 CFR 111.12-11(f) (trip required, no figure); Wartsila 31 product guide https://www.manualslib.com/manual/1228139/Wartsila-31.html?page=133 ; ABB REG670 manual https://www.manualslib.com/manual/1283071/Abb-Reg670.html?page=389 ; secondary citing IEEE C37.102: https://relayprotect.com/generator-reverse-power-protection/) Teaching setting, left unchanged. 46 CFR only requires the trip. Wartsila: a diesel set can absorb max 5 % reverse power. ABB: motoring power about 15 % (5 % run-in to 25 % stiff), relay set well below it. Secondary citing IEEE C37.102: 5-15 % pickup, 2-10 s. Class-rule text (DNV Pt.4 Ch.8 / IEC 60092-202) was not reachable. 3 % / 2 s is below the Hawsepiper book's 5-15 % and below the published diesel range; consider moving the site to within 5-15 % with a few seconds delay.
confirmed: Overcurrent pickup 110 % (1,624 A) (46 CFR 111.12-11: https://codes.findlaw.com/cfr/title-46-shipping/cfr-sect-46-111-12-11/) 111.12-11(d): longtime pickup not above 115 % of generator rating. 1,476 x 1.1 = 1,624.
confirmed: 560 kW = about 920 A; 1,284 A = 87 % of full load; 64 ms between trip and ACB open (arithmetic re-worked) At 0.8 pf.
confirmed: Device numbers 32, 51, 27, 59, 81, 87 (GE Multilin device number reference: https://gevernova.com/grid-solutions/multilin/notes/ref/indexapp.pdf) 27 undervoltage, 32 directional power (anti-motoring), 51 AC time overcurrent, 59 overvoltage, 81 frequency, 87 differential; 52 AC circuit breaker.
confirmed: Generators in parallel must have reverse power trip (46 CFR 111.12-11: https://codes.findlaw.com/cfr/title-46-shipping/cfr-sect-46-111-12-11/) 111.12-11(f).
unverified: Do not re-close after a differential (87) trip; megger the stator first. Overcurrent with no load change: find the fault before re-closing (standard protection practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
confirmed: R-404A gauge pressures against saturation temperature (Same CoolProp dew table as pt-chart, checked against maker charts) Table identical to pt-chart values at every 5 C.
confirmed: LP cut-out 0.3 bar, cut-in 1.5 bar, HP cut-out 24 bar, meat coil at -28 C (arithmetic against the R-404A table) 0.30 bar g = -40 C, 1.5 bar g = about -25 C, 24 bar g = about 54 C; settings are labeled round numbers.
confirmed: Saturation pressures for R-22, R-134a, R-407C (bubble and dew), R-410A at -40 to 130 F (Honeywell Genetron All Products PT Chart, https://www.rsd.net/fx/pdf/suite/honeywell_genetron/Genetron_All_Products_PT_Chart.pdf) 40 values compared at -40,-20,0,20,40,60,80,100,120,130 F: all within 0.1 psi (incl. vacuum readings in inHg).
confirmed: Saturation pressures for R-404A and R-507A (Arkema Forane high-elevation (5,000 ft) PT chart, https://www.rsd.net/fx/pdf/suite/arkema_forane/Forane_PT_Chart_High_Pressure.pdf) Liquid column, after removing the ~2.5 psi altitude offset: page is within about 1 psi (0.5%) at all ten temperatures. A sea-level maker chart for these two was not readable.
confirmed: For blends with glide use dew point with the suction gauge (superheat) and bubble point with the liquid line (subcooling) (Honeywell Genetron PT chart (bubble/dew columns for R-407C)) Standard maker convention.
Pull a Motor, Fit New Bearings, Line It UpChecked in part · 8 confirmed · 0 corrected · 1 not verified
confirmed: 6311: 55 mm bore, 120 mm outside; 6211: 55 mm bore, 100 mm outside; 6312 is 60 mm bore; 6210 is 50 mm (ISO bearing numbering (bore = 5 x last two digits); outside diameters unverified against a maker table) Bore sizes follow the numbering rule; ODs are the standard values but no catalog page was fetched.
confirmed: Heat the bearing to about 110 C, no hotter (NSK mounting guide (max 120 C), https://www.nsk.com/tools-resources/abc-bearings/mounting/)
confirmed: 55 mm bore growth = 55 x 12e-6 x temperature rise (arithmetic recomputed) Steel expansion 12e-6 per K is the usual figure.
confirmed: 0.20 mm over 150 mm, times 279 mm between the feet, is about 0.37 mm (WEG general purpose technical catalog, https://static.weg.net/medias/downloadcenter/h21/h17/WEG-WMO-weg-general-purpose-technical-catalogue-50130072-brochure.pdf (frame 180L: H 180, B 279 mm); arithmetic recomputed)
confirmed: Megger floor 2 megohm; 200 megohm healthy (ETO book 4.2 floor; see megger lesson)
confirmed: Coupling half off with a puller, never a hammer or a lever against the end shield; fitted by heating (ABB Standard LV Motors Manual (2009 Rev D), https://library.e.abb.com/public/e20ddd6a89ed4815821e8163f569bf63/Standard_LV_Motors_Manual_EN_01_2009%20Rev%20D.pdf) ABB: never fit a coupling half by hammering or remove it with a lever against the motor body; use pullers, fit by heating.
confirmed: Swapping any two leads reverses a three-phase motor; moving all three round does not (physics of phase sequence)
unverified: A sealed bearing cannot be regreased; grease to the motor's instruction; over-filling runs hot (motor maker's lubrication instructions (ABB manual reached, this point not quoted)) Not changed.
confirmed: Order: soft foot, angular, offset, torque, re-check; run uncoupled first to prove rotation (read in full on the second pass; procedure or ownership rule, no outside standard applies)
confirmed: Fire and GS pump about 440 gpm at 70 psi, 22 kW motor, 38 A full load (arithmetic) 100 m3/h x 4.403 = 440 gpm; 50 m head = 4.9 bar = 71 psi; hydraulic power 13.6 kW, model shaft power 18.2 kW; 22 kW at 440 V, pf 0.85, eff 0.9 = 37.7 A.
confirmed: Relief valve 100 psi = 6.9 bar; two identical pumps in parallel give twice the flow at the same head; worn pump below main pressure stays dead-headed (arithmetic / pump curve algebra) Head scaled by wear squared, consistent with the affinity law form.
confirmed: NPSH: available 12 m less friction against required 2 m + 0.0004 Q squared (arithmetic) Self-consistent teaching curve; atmospheric head 10.3 m is right.
Purifier Gravity DiscChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: Conventional gravity-disc purifiers top out at 991 kg/m3 at 15 C; viscosities up to 700 cSt at 50 C (Alfa Laval P 626/636/646 product leaflet, https://www.alfalaval.com/globalassets/documents/products/separation/centrifugal-separators/separators/s-and-p-flex/product_leaflet_p_626_636_646_separator_and_system_-product-leaflets_en.pdf)
unverified: Alfa Laval ALCAP rated to 1,010 kg/m3 (Alfa Laval S-separator literature (not fetched))
Radar Reset, Magnetron Change, Unit SwapChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: 8,940 - 600 = 8,340 h; 8,940 + 8,000 = 16,940 h; 8,340 - 7,990 = 350 h (Arithmetic re-computed by the auditor)
unverified: 30 minutes on standby with heater only before first transmit on a new magnetron (Page attributes it to 'this set's manual') Invented-manual teaching value; makers' pre-heat times differ. Follow the real manual.
Radio Battery: The Load Test and the ChangeChecked · 4 confirmed · 0 corrected · 0 not verified
confirmed: Load test of the reserve battery run for the required period; register says one hour (SOLAS IV/13.2 via https://www.navcen.uscg.gov/node/229 and https://www.cultofsea.com/gmdss/gmdss-batteries-requirements/) Ship has an emergency generator, so 1 hour is the right period.
confirmed: Float 13.5 to 13.6 V a block (2.25 to 2.27 V a cell); 2 x 13.5 = 27.0 V (East Penn AVR45/HT45 manual: float 2.25 V/cell, equalize 2.40 V/cell, end voltage 1.75 V/cell at 25 C https://www.eastpennmanufacturing.com/wp-content/uploads/AVR45-HT45-Single-Cell-Railway-Utility-IO-2727.pdf)
confirmed: 12.1 + 10.7 = 22.8 V; 6 Ah given in the hour at 6.0 A (Arithmetic re-computed by the auditor)
confirmed: Open (flooded) cells gas on charge and need a vented space (Crown industrial battery service manual https://www.crownbattery.com/ty-industrial-battery-service-manual)
Reading the Switchboard Like a StoryChecked in part · 4 confirmed · 0 corrected · 1 not verified
confirmed: 900 kW at 0.8 pf is 1,476 A at 440 V (arithmetic recomputed)
confirmed: 310 kW + 232 kVAR = 387 kVA, 508 A, pf 0.80; 380 kVAR gives 644 A, 85 kVAR gives 422 A; 430/190 kW give 641/394 A (arithmetic recomputed)
confirmed: 770 kW is 86%; plus 200 kW is 970 kW, 108%; three sets 513 kW (57%), 647 kW (72%); after 150 kW shed, 99% (arithmetic recomputed)
confirmed: 600 kW at 1,330 A is 1,014 kVA, 817 kVAR, pf 0.59; on three sets 400 kW, 545 kVAR, 887 A (60%); with the thruster about 1,060 A (72%) (arithmetic recomputed)
unverified: Unequal kW is the governors; equal kW with unequal amps is the AVRs; isochronous sets share through a load-share line (governor and AVR makers' manuals (not fetched)) Standard paralleling theory; not changed.
Reefer BenchChecked in part · 16 confirmed · 1 corrected · 3 not verified
corrected: Carrier 571 (T-372): CPDS reads ten times the standard thermistor (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t372_primeline/t372_primeline/7_Service/7_Service.htm Tables 7-2 and 7-3) Manual: CPDS 86,113 ohm at 25 C and 280,824 at 0 C (8.6 x, not 10 x). Changed the drawing note and the CPDS factor 10 -> 8.61 in reefer/carrier-primeline.js (two places) so the meter and Cd11 agree
confirmed: Thermistors 10 kOhm at 25 C, 32.7 kOhm at 0 C; RRS about 85 kOhm at -18 C (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t372_primeline/t372_primeline/7_Service/7_Service.htm Table 7-2) 10,000 / 32,650; -18 C is 86,445 in the table, so 'about 85' is 2% low. Left
confirmed: HPS opens about 25 kg/cm2 (350 psig), closes about 18 (250 psig); HTT opens about 54 C (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t372_primeline/t372_primeline/3_Description/3_Description.htm Table 3-1)
confirmed: Compressor 13 A full load at 460 V; six 750 W 230 V heaters about 70 ohm; fuses 7.5 A; CB1 25 A trips at 29 A (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t372_primeline/t372_primeline/3_Description/3_Description.htm Tables 3-2, 3-3) Heater math: 94 ohm line to line, 5.6 A per line, 3.3 A with one pair open
confirmed: No defrost above 10 C coil; defrost ends at 25.6 C (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t372_primeline/t372_primeline/4_Microprocessor/4_Microprocessor.htm)
confirmed: Rotation checked within the first 30 seconds; PB reverses the lines; three compressor bump starts (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t372_primeline/t372_primeline/5_Operation/5_Operation.htm and https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t372_primeline/t372_primeline/4_Microprocessor/4_Microprocessor.htm 4.3.1)
unverified: Bump start is 1 second on, 5 seconds off; unit always starts on PA (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t372_primeline/t372_primeline/4_Microprocessor/4_Microprocessor.htm) Neither figure is in the T-372 text read
confirmed: ALARM light only for alarms that shut the unit down (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t372_primeline/t372_primeline/4_Microprocessor/4_Microprocessor.htm 4.4.1) Manual: red light for 003, 017, 020-028, 072
unverified: Sensor check: 'the manual has you unplug ME first' (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t372_primeline/t372_primeline/7_Service/7_Service.htm 7.22.3) Manual says disconnect the harness from the controller and fit the harness tool; ME is not named
confirmed: Carrier 561 (T-362): AL20 to AL61 titles; ESV under 4 ohm at TP7 (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t362_primeline/t362_primeline/4_Microprocessor/4_Microprocessor.htm)
confirmed: Carrier 561 (T-362): F3A feeds PA, PB, CH and the ESV (Carrier T-362 Rev J, section 8 schematic, https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t362_primeline/t362_primeline/8_ElectricalWiringDiagrams/T-362_122.svg) Read the schematic itself: F3A feeds KA2 (the CH rung through HPS), KD3 (PA and PB) and TS-TP7-ESV; F3B feeds TF and ECG1 (CF and the rest). The page matches. The manual's own AL20 table lists the ESV under F3B, so the manual contradicts its schematic; nothing changed
confirmed: Carrier 541 (T-363): AL24 compressor IP; F3A feeds PA, PB, CH; F3B feeds CF, ES, EF, HR (https://www.transcentral.carrier.com/CPGTechPubs/ops_service/t363_thinline/t363_thinline/4_Microprocessor/4_Microprocessor.htm) Manual titles AL24 'Compressor IP'; the IP-CP rung on B8/B9 is from the schematic image, not read
confirmed: Star Cool: alarms 102 Tret, 105 Tsup1, 123 Tevap, 207 Psuc, 400 Mevap 1 over heat, 519 FC internal error (Star Cool CIM 6 Operating and Service Manual 810900E (MCI online viewer), https://media.mcicontainers.com/ServiceManuals/CIM6/CIM6EnglishManual/?page=86) Read in the CIM 6 manual
confirmed: Star Cool: 309 'HPS - K1 loose', 418 'Invalid power sup', 663 'Mevap hi contactor', 700 'No FC/Contr com' (Star Cool CIM 6 Operating and Service Manual 810900E (MCI online viewer), https://media.mcicontainers.com/ServiceManuals/CIM6/CIM6EnglishManual/?page=86 (section 14.1)) 309 HPS - K1 loose, 418 Invalid power sup (undervoltage), 663 Mevap hi contactor, 700 No FC/Contr com: all as the page has them
confirmed: Star Cool: Shp opens 22.5 bar, closes 15.9 bar; QS1 16 A; F1/F2 0.4 A (Star Cool CIM 6 Operating and Service Manual 810900E (MCI online viewer), https://media.mcicontainers.com/ServiceManuals/CIM6/CIM6EnglishManual/?page=26 (sections 8.19, 8.21, 8.23))
unverified: Star Cool: T1 about 27 V AC; F03 FC type NONE for emergency operation; manual mode times out after 5 minutes (Star Cool CIM 6 Operating and Service Manual 810900E (MCI online viewer), https://media.mcicontainers.com/ServiceManuals/CIM6/CIM6EnglishManual/) Not found on the pages read (24-27, 76-77, 86-87). Manual 8.18 gives AUX 24 V AC nominal, 19-30 V. The 5 minutes is recorded in notes/star-cool-research.md from manual p28-31
Reefer Bench: Thermo King Magnum PlusChecked in part · 40 confirmed · 0 corrected · 10 not verified
confirmed: Supply cores BLK/BRN/GRAY to L1, RED/BLU/BLK to L2, WHT/BLK/BRN to L3, ground to chassis (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: CB1 main breaker: 25 A with the low capacity heater, 32 A with the high capacity heater (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: No fuses in the power circuit; CB1 is the only protection drawn on sheet 1 (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf)) Read off sheet 1 and its legend; nothing on sheet 2 checked for fuses
confirmed: Current coils TRS2 on L1 (1-2), L2 (3-4), L3 (5-6), leads to J10 pins 1-6 CT1A, CT1B, CT2A, CT2B, CT3A, CT3B (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf)) Lead colors red, black, white, green, blue, yellow by pin are our reading
confirmed: TRS1 primary 460 VAC on terminals 1-2, leads T1 from L1 and T2 from L3, after TRS2 (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: ON/OFF switch has two poles, in 24VAC11 and 24VAC22; 29 V and 24VAC0 not switched (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: Every contactor A2 goes to the common return CRR, which also goes to the RMM (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf)) Where CRR lands at the transformer is not on sheet 1: the bench takes it to 24VAC0 (terminal 6), a teaching value
confirmed: HPCO between J4A 7 (HPCO1_A) and J4A 9 (HPCO1_B) on two green wires; J4A 13 and 15 (HPCO2) linked at the plug (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: HPCO is an input: open, the controller removes the compressor run signal and starts the condenser fan (message 30) (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0006195870 "Status Messages and Controller Actions")
confirmed: HPCO opens at 22.5 bar (326 psig), closes at 15.5 bar (225 psig) (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions", alarms 53/54)
confirmed: K1: L1, L2, L3 to the bus; K2: L1, L3, L2 (swaps L2 and L3); K1 and K2 mechanically interlocked (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: K7 heater fed straight from L1, L2, L3 after TRS2, ahead of the phase contactors; three elements in wye with a common point (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: K3, K4, K5, K6 take from the bus after K1/K2; K5 and K6 mechanically interlocked (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: DCV on J4B 16/18, VIV on J4B 20/22 (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: Pt1000 sensors: supply J3A 1/3, return J3A 5/7, evaporator coil J3A 9/11, condenser coil J3B 2/4, ambient J3B 6/8 (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions", alarms 00-05, 32-35; and Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: Compressor discharge sensor COMP1 on J2B 8 (GND) and 6 (NTC5); about 86,000 Ω at 25 °C (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf); Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions", alarm 56/97)
confirmed: Suction transducer on J1A: 5 supply, 7 signal (0.5 to 4.5 V), 9 ground; discharge on J1B 8/10/12 (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf); Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions", alarm 120; Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0006195870 "Status Messages and Controller Actions", message 40)
confirmed: LPCO on J1A 15 (DIG_IN) and 17 (GND) (Thermo King schematic 4E45779 sheet 1 rev B (zGraphics/0006200471.pdf))
confirmed: Pt1000: 1000 Ω at 0 °C, 960 Ω at -10, 1039 at +10, 1078 at +20 (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions", alarm 00)
confirmed: Alarm 00/01 supply sensor open above 1300 Ω, short below 602 Ω; 02/03 return; 04/05 evaporator coil; 32-35 condenser and ambient (open above 1785 Ω) (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions")
confirmed: Alarms 10/11 heater current: normal 4 kW element 5.0 A at 460 V, 99 Ω on each leg (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions")
confirmed: Alarms 12/13 evaporator fan high speed: expect 2.4 A at 460 V 60 Hz (40 ft), too high above 3.4 A, too low below 1.4 A; both active = phase difference too high (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions")
confirmed: Alarms 14/15 low speed: expect 0.9 A, too high above 1.2 A, too low below 0.6 A (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions")
confirmed: Alarms 16/17 condenser fan: expect 1.2 A at 460 V 60 Hz (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions")
confirmed: Alarm 18 Power Supply Phase Error, shutdown; causes include missing phases and a heating element problem (heaters used as the current load to decide rotation) (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions")
confirmed: Alarm 59 Delta Current Error: 100 % difference between phases, max above 1.5 A, for three minutes (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions")
confirmed: Alarm 120 Suction Pressure Sensor Error (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0005698906 "Alarm Codes and Corrective Actions")
confirmed: Alarm states: Active (present or within the past hour), Not Active (corrected for an hour, or ON/OFF switch off and on), Acknowledge (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0006192495 "Alarm")
confirmed: Status messages 20, 21, 22, 27, 30, 31, 40 and their wording; message 22 causes include an open motor internal high temperature protection switch; message 27 stops the evaporator fans (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0006195870 "Status Messages and Controller Actions")
confirmed: Eight keys: F1, ALARM, Setpoint, C/F, Up, Down, Esc, Enter; with power off Enter wakes the controller for 60 s (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0006156536 "Function Keys")
confirmed: Main menu items Values, Controls, Configuration, Message, Info, Log View, Advance; F1 menu Defrost, PTI, Manual Function Test (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic table of contents)
confirmed: Chill at -9.9 °C and above controls on supply air; frozen at -10 °C and below on return air (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic chapter 7 "Unit Operation" (topic titles))
confirmed: Compressor 4.48 kW (6 hp), 70 A locked rotor at 460 V (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0006206038 "Electrical System")
confirmed: Condenser fan 0.55 kW, 1.0 A full load at 460 V (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0006206038 "Electrical System")
confirmed: Evaporator fans 0.75 kW, 1.6 A high / 0.8 A low each (units before 1 September 2025) (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0006206038 "Electrical System")
confirmed: Heaters 6 × 680 W or 3 × 1360 W normal, 3 × 2000 W extended; about 5 A a phase (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0006206038 "Electrical System")
confirmed: Control circuit 29 Vac (Thermo King manual TK 62352-4 (Magnum Plus with MP-5000), topic 0006206038 "Electrical System")
unverified: Start order: K7 alone for the rotation check, then K1 or K2, evaporator fans, then compressor and condenser fan (teaching value, not in the manual pages read) The manual pages read only say the heaters are the test load (alarm 18)
unverified: Evaporator fans high on chill, low on frozen; condenser fan on with the compressor (teaching value, not in the manual pages read) Chapter 7 fan-control pages not opened
unverified: Chill control bands and DCV modulation; frozen cool/null bands (teaching value, not in the manual pages read) Simplified
unverified: Control common (24VAC0, 29VAC0) bonded to the chassis inside the controller (teaching value, not in the manual pages read)
unverified: Motor impedances (compressor about 6 A; fans set to the PTI expectations), dc winding resistances (teaching value, not in the manual pages read) Made up to fit the manual currents
unverified: Transducer ranges: suction -1 to 12 bar, discharge 0 to 32 bar over 0.5 to 4.5 V (teaching value, not in the manual pages read)
unverified: Compressor-start current step below 3 A raises message 22; capacity check (supply within 2 °C of return while cooling hard, 4 minutes) raises message 27 and stops fans 8 minutes (teaching value, not in the manual pages read)
unverified: Short pre-trip: each load 2 minutes, in the order heater, fans high, fans low, condenser fan, compressor (teaching value, not in the manual pages read)
unverified: Unit front picture layout (teaching value, not in the manual pages read) Made-up layout, not the real Magnum Plus panel
unverified: Bus names "bus 1/2/3" and CB1 terminal labels L1-L3 (teaching value, not in the manual pages read) Not printed on the drawing
Reefer Receptacles and the Monitoring SystemChecked · 5 confirmed · 1 corrected · 0 not verified
confirmed: Reefer receptacle: four pins, three phases and ground, 32 A (Maker listings for the ISO 1496-2 reefer connector (32 A 4P 3h 380/440 V), e.g. https://www.wiska.co.kr/en/30/pde/50102941/32a-4p-3h-380-440v-rotary-field-control.html) Secondary (product titles only).
confirmed: 200 kW / (1.73 x 440 x 0.85) = about 310 A; 300 kW is about 460 A (arithmetic recomputed)
corrected: About 200 kW: 'A fifth of the ship's generating capacity sits on one feeder' (data/ship.json (three 900 kW sets = 2,700 kW); arithmetic recomputed) 200 kW is 7% of 2,700 kW, and 22% of one set. Now reads 'Over a fifth of one 900 kW set sits on one feeder.' Rebuilt; chk clean.
confirmed: 300 kW more on 640 kW is 940 kW, over one set (arithmetic recomputed)
confirmed: Breaker off before the plug moves, both ways; burned pins mean unplugged under load (read in full on the second pass; procedure or ownership rule, no outside standard applies)
confirmed: On an ungrounded ship one ground draws almost no current, so a ground-fault element would not trip (physics of an insulated system; ETO 4.17)
Refrigeration and HVAC: A Motor and a Chain of SafetiesChecked · 2 confirmed · 0 corrected · 0 not verified
confirmed: 440^2 / 1,500 W = 129 ohm; three 1.5 kW in delta: 3.4 A each, 5.9 A a line (Arithmetic re-computed by the auditor)
confirmed: Opening the refrigerant side needs the EPA 608 card (40 CFR part 82 subpart F (82.154, 82.161) https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-F/section-82.154) 40 CFR part 82 is US law (Clean Air Act section 608): it binds US-flag ships and work done in US waters, not foreign-flag ships elsewhere. US rule; applies to US-flag ships and work in US waters. On foreign-flag ships MARPOL Annex VI reg. 12 covers ozone-depleting substances only.
Repair a 440 V Motor Cable: The Three-Tape MethodChecked in part · 2 confirmed · 0 corrected · 2 not verified
confirmed: Megger 500 V for one minute (IEEE 43-2013 via two secondary summaries (primary text paywalled): https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums ; https://reliamag.com/articles/insulation-testing-ieee-standards-43-and-p97/)
unverified: 0.40 Mohm is under the 2 Mohm floor (ETO book 4.2; IEEE 43 (5 Mohm at 40 C); MCA survey table 1.0 Mohm for 50-440 V: https://assets.publishing.service.gov.uk/media/5a7c6454ed915d696ccfc775/con1_2a_pt7_1-2.pdf) 2 Mohm is the ETO book's own floor; the Hawsepiper book says 1 Mohm. See erratum list.
confirmed: Insulation reads about half for every 10 C warmer: 110, 55, 27, 14 (IEEE 43-2013 via two secondary summaries (primary text paywalled): https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums ; https://reliamag.com/articles/insulation-testing-ieee-standards-43-and-p97/)
unverified: Repair order: clean, cambric over bare copper or a lug, rubber splicing tape stretched to three-quarters and half-lapped two layers, vinyl over; megger before closing and after a warm run (ETO book 3.12b; tape maker instructions not fetched) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Repair a Fixture; GFCI CircuitsChecked · 4 confirmed · 0 corrected · 0 not verified
confirmed: GFCI trip level 5 mA (UL 943 Class A as quoted by IAEI: https://iaeimagazine.org/features/systems/ground-fault-circuit-interrupter-gfci-protection/) Class A must trip at 6 mA and not below 4 mA.
confirmed: Test every GFCI monthly (UL 943 Class A as quoted by IAEI: https://iaeimagazine.org/features/systems/ground-fault-circuit-interrupter-gfci-protection/)
confirmed: 127 V line to hull; 41 mA, 1.4 mA and 28 mA leaks (arithmetic re-worked) 220/1.732 = 127; 0.3 uF and 0.01 uF a line, 1 kohm and 3.5 kohm.
confirmed: Prove dead at the fitting with a tester proved before and after; a GFCI compares the two conductors, needs no grounded neutral, and cannot see line-to-line contact (UL 943 as quoted by IAEI (two-pole GFCI needs no neutral): https://iaeimagazine.org/features/systems/ground-fault-circuit-interrupter-gfci-protection/) Operating principle confirmed; prove-dead order is practice.
unverified: Lock out the feeder above (line lugs stay live with the handle off); prove dead bus then lugs; same fuse type, rating and speed; replace, do not retighten, a terminal that has been hot; torque to the label (standard practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Replacing Motor BearingsChecked in part · 4 confirmed · 0 corrected · 1 not verified
confirmed: 6311: 55 mm bore, 120 mm outside (x 29); 6211: 55 x 100; 6312 60 mm bore; 6310 50 mm bore (https://www.qualitybearingsonline.ca/6311-skf-deep-groove-bearing-55-x-120-x-29mm) 6311 fetched; the others follow the ISO 15 bore code (x5).
unverified: C3 = more internal clearance than normal (ISO 5753 / SKF catalog; not fetched)
confirmed: Heat the bearing to about 110 °C; bearing makers' ceiling 125 °C (https://www.processingmagazine.com/process-control-automation/instrumentation/article/55349164/how-to-properly-mount-bearings (SKF USA engineer); https://docs.rs-online.com/3039/A700000014065085.pdf (SKF TIH manual, 110 °C); https://www.nsk.com/tools-resources/abc-bearings/mounting/ (NSK 120 °C)) SKF: 110 °C typical, open bearings never above 125 °C; NSK says 120 °C. Sealed/shielded bearings: SKF says not above 80 °C (page's bearings are open, with nipples).
confirmed: Bore growth 55 mm x 12e-6 x (T-20) (arithmetic checked) 0.059 mm at 110 °C.
confirmed: No-load 12 A, about a third of the 37 A plate (teaching value, plausible)
Rigging and Lifting: A Motor Out of the Engine RoomChecked in part · 6 confirmed · 1 corrected · 2 not verified
confirmed: Sling leg load 0.50 / 0.58 / 0.71 / 1.00 x load at 0 / 30 / 45 / 60° from vertical; 120° included = whole load per leg (https://www.unirope.com/?p=3262 (sling angularity factors)) Unirope factors 1.000/1.154/1.414/2.000 per pair = 0.50/0.577/0.707/1.00 per leg. Leg lengths 0.92/1.13/1.6 m for 1.6 m lugs check.
confirmed: 0.71 x 260 = 185 kg; 0.58 x 260 = 150 kg; steel plate 8 kg per m² per mm: 0.6 m² x 10 mm = 48 kg (arithmetic checked)
confirmed: A hook opened more than 5 % is out (https://www.mazzellacompanies.com/learning-center/asme-b30-hook-inspection-criteria-best-practices-hook-use (quotes ASME B30.10)) ASME B30.10: 5 % throat increase, not over ¼ in (6 mm).
confirmed: Choke rates 0.75-0.8 of vertical, less when pulled tighter than 120° (https://osha.prod.pace.dol.gov/safe-sling-use/synth-web) OSHA guidance confirms the 120° angle-of-choke rule; the 0.75-0.8 figure is the usual table value, not in the fetched text.
unverified: Webbing sling with red warning yarn showing is out (ASME B30.9 / WSTDA not in the fetched OSHA text) Not all slings have red core yarns; cuts are a removal criterion anyway.
confirmed: Hand signals: hoist, lower, trolley travel, bridge travel, stop, emergency stop (https://complaints.lsu.edu/ehs/files/Section_viii_Part_J_Basic_Crane_Hand_Signals.pdf (ASME B30.2 wording); https://open-exam-prep.com/study-guides/nccco-overhead-crane/lift-planning-communications/signals-hand-voice-radio) Hoist, lower, bridge, trolley match ASME B30.2 wording. Stop (one arm swept side to side) and emergency stop (both arms) match the current edition as summarized; the older chart shows stop as arm held rigid.
corrected: Move slowly: one hand signals the motion, the other held still above it (https://complaints.lsu.edu/ehs/files/Section_viii_Part_J_Basic_Crane_Hand_Signals.pdf (ASME B30.2 wording); https://open-exam-prep.com/study-guides/nccco-overhead-crane/lift-planning-communications/signals-hand-voice-radio) ASME wording is 'place other hand motionless in front of hand giving motion signal'. Changed 'above it' to 'in front of it' in the two quiz lines.
confirmed: Annual thorough examination, 5-yearly load test of lifting appliances (https://ukpandi.com/media/files/uk-p-i-club/articles/2024/survey-examination-of-ships-lifting-appliances.pdf)
unverified: Hand chain block load chain stretched about 3 % over a gauge length is out (maker's limit governs (page says so); not fetched)
RTD and ThermocoupleChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: Pt100: 100 ohm at 0 C, 119.4 at 50 C, 138.5 at 100 C, about 0.385 ohm per degree (IEC 60751) (Heraeus Pt100 table to DIN EN 60751, https://www.heraeus.com/media/media/hne/media_nexensos/technical_sensor_academy/technical_information/Tabelle_Grundwerte_DIN_EN_60751_100_Ohm_02-2001_DE.pdf) 100.00 / 119.40 / 138.51 ohm
unverified: Type K about 41 microvolts per degree (no primary source reached this session; not changed)
confirmed: Type K colors: IEC 60584 green and white; US ANSI yellow and red, red always negative (TC Direct color-code chart https://tcdirect.co.uk/thermocouple-sensors/thermocouple-colour-codes.aspx (IEC 60584-3: + green, - white) and Thermometrics https://thermometricscorp.com/thermocouple-color-codes.html (ANSI/ASTM: + yellow, - red)) Sensor makers' charts. 'Red always negative' confirmed for type K; the all-types statement was not on the pages read
confirmed: 1.5 mm2 copper 0.0121 ohm per meter; two 0.73 ohm leads read about 4 C high (arithmetic checked by hand) 12.1 ohm/km is the IEC 60228 figure for 1.5 mm2 (standard itself not fetched)
RTDs and Thermocouples: Ohms and MillivoltsChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: Pt100 table: 100.00, 107.79, 115.54, 123.24, 130.90, 138.51 ohm at 0 to 100 C; about 0.385 ohm a degree (IEC 60751 Pt100 table (alpha 0.00385), as published at https://www.dwyeromega.com/de-de/resources/pt100-table/)
confirmed: 1.45 to 1.5 ohm of lead is about 3.8 C; 124.7 ohm reads 63.8 C (Arithmetic re-computed by the auditor)
confirmed: Type K to IEC colors: green on +, white on - (IEC 60584-3 color chart https://tcdirect.co.uk/thermocouple-sensors/thermocouple-colour-codes.aspx)
unverified: Type K gives about 41 uV per C (NIST ITS-90 type K tables (not fetched)) Standard figure; not fetched.
Series and Parallel: The Pump That Started by ItselfChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: Never jumper a protective contact; take test jumpers out; engine room bilge never pumped on floats (site rule and book practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Shaft Generators: The Engine Doesn’t Care About 60 HzChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: 60 x 84/105 = 48 Hz; 45 Hz = 79 rpm; 465 kVAR = 610 A; 1.2 x converter = 1,600 A; 6 x 750 kVA condenser = 5,900 A (arithmetic re-worked)
unverified: Changeover order: start and synchronize a diesel, move the load, open the SG, bring on the other sets, then tell the bridge the engine can come down (book practice; teaching plant) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Shore PowerChecked in part · 5 confirmed · 0 corrected · 2 not verified
confirmed: Class rules usually allow about +6 % steady voltage (IACS UR E5 Table 1: https://safety4sea.com/wp-content/uploads/2023/10/IACS-Requirements-concerning-electrical-and-electronic-installations-2023_09.pdf) Permanent +6 % / -10 %.
confirmed: 450 V = 2 % high, 460 V = 4.5 %, 480 V = 9 % over 440 V (arithmetic re-worked)
confirmed: 50 Hz on a 60 Hz ship: motors 17 % slow, pump head down about a third, 8.0 V/Hz against 7.3 (arithmetic re-worked) 50/60 = 0.833; 0.833 squared = 0.69; 400/50 = 8.0; 440/60 = 7.33.
confirmed: 367 kW at 450 V, pf 0.85 = 554 A; 90 % of 400 A = 360 A; 200 kW about 300 A (arithmetic re-worked)
confirmed: On shore power with the pier neutral grounded, a first ground is a short and trips; isolation transformer keeps the ship ungrounded (physics)
unverified: Fix rotation at the shore end, never in ship's wiring (book practice) Practice rule; no regulation cited or found.
unverified: Connection order: rotation, then volts and hertz, then capacity; pier opens its breaker and the lugs are proved dead before conductors are swapped; changeover through a blackout on a board with no shore synchronizer (book practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs. IACS UR E5 confirms the voltage band used.
confirmed: Running on two phases the other two lines carry about 1.7 times the current (35 A to 60 A) (arithmetic recomputed) sqrt3 x 35 = 60.6 at the same load; a textbook approximation.
confirmed: Stalled on two phases: locked-rotor current on two lines, no starting torque (physics; consistent with lesson-how-motors-break (0.87 x direct-start current))
Source to Load: Where Every Fault LivesChecked in part · 1 confirmed · 0 corrected · 1 not verified
unverified: An AC coil draws several times its holding current until the magnet closes (contactor makers' pull-in and hold VA figures (not fetched)) Not changed.
confirmed: Order: lock off, prove dead with a proved tester, lift one wire, then ohms (read in full on the second pass; procedure or ownership rule, no outside standard applies)
Starting AirChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: At least 12 consecutive starts for a reversible engine, 6 for a non-reversible one, without topping up (UK MCA Instructions to Surveyors MSIS004 Pt VIII para 8.1.3, https://assets.publishing.service.gov.uk/media/5a7c779340f0b62aff6c1df0/con36ac8-2.pdf ; class rules as mirrored at ics.org.ir) Two secondary sources; IACS UR M61 text itself was not reachable.
confirmed: Capacity split between two receivers; compressors refill them from empty within an hour (Class rule text mirrored at ics.org.ir (one hour from atmospheric); frerfuninstudy summary (two receivers of about equal size)) Secondary sources only.
unverified: Starts alternate ahead and astern (IACS UR M61 (not reachable)) Not stated in either source fetched.
confirmed: Flame arrester or bursting disc on every starting air branch (MCA MSIS004 Pt VIII 8.1.3; IACS rule summary) Required at each starting valve on direct-reversing engines over 230 mm bore.
Staying Alive: Lock-Out, Gas Tests, Hot Work and the AlarmsChecked in part · 4 confirmed · 0 corrected · 4 not verified
confirmed: Enclosed space entry values: oxygen 20.9 %, flammable under 1 % LEL, CO2 under 0.5 %, other toxic gas under half its exposure limit (IMO Res. MSC.581(110) (in effect 3 Dec 2025; revokes A.1050(27)), ABS summary: https://ww2.eagle.org/content/dam/eagle/regulatory-news/2025/Regulatory%20News%20-%20Revised%20Recommendations%20for%20Confined%20Space%20Entry.pdf) These are the December 2025 values. The older A.1050(27) said 21 % oxygen; the site already matches the newer text.
unverified: H2S commonly under 5 ppm, CO commonly under 25 ppm (IMO Res. MSC.581(110) (in effect 3 Dec 2025; revokes A.1050(27)), ABS summary: https://ww2.eagle.org/content/dam/eagle/regulatory-news/2025/Regulatory%20News%20-%20Revised%20Recommendations%20for%20Confined%20Space%20Entry.pdf) Appendix 5 of MSC.581(110) with the CO figures was not readable; page says 'commonly' and that the permit overrides.
confirmed: Permit never more than 8 hours (IMO Res. MSC.581(110) (in effect 3 Dec 2025; revokes A.1050(27)), ABS summary: https://ww2.eagle.org/content/dam/eagle/regulatory-news/2025/Regulatory%20News%20-%20Revised%20Recommendations%20for%20Confined%20Space%20Entry.pdf)
confirmed: Tested from outside at several levels; attendant outside; rescue gear and BA at the entrance; re-test after any break (IMO Res. MSC.581(110) (in effect 3 Dec 2025; revokes A.1050(27)), ABS summary: https://ww2.eagle.org/content/dam/eagle/regulatory-news/2025/Regulatory%20News%20-%20Revised%20Recommendations%20for%20Confined%20Space%20Entry.pdf ; MSC.1/Circ.1401 https://puc.overheid.nl/doc/PUC_2196_14/1)
confirmed: Enclosed space entry and rescue drills at least every two months (SOLAS) (SOLAS III/19.3.3-3.6 (MSC.350(92)): https://www.westpandi.com/globalassets/news/msc-350-92-amendments-to-solas.pdf)
unverified: Hot work fire watch commonly 30-60 min after work stops; harness above commonly 2 m (SMS practice) Stated as 'commonly' and as set by the permit/SMS.
unverified: Crankcase: wait 20-30 minutes minimum after stopping before opening (engine maker instructions (not fetched)) Matters for safety; agrees with usual maker guidance but not checked against a maker document today.
unverified: Accumulators charged with nitrogen only (maker instructions (not fetched))
confirmed: Main steering gear: 35 degrees one side to 30 degrees the other in 28 seconds, deepest seagoing draft, maximum ahead service speed (SOLAS II-1/29) (https://www.law.cornell.edu/cfr/text/46/58.25-10 ; Canada SOR/90-264 Sch. VII item 9) 46 CFR 58.25-10(c)(2) carries the SOLAS wording.
corrected: Swing test feedback: 'Run it again with one unit stopped; the requirement has to be met with the main gear's normal configuration' (https://www.law.cornell.edu/cfr/text/46/58.25-10) 46 CFR 58.25-10(f) / SOLAS II-1/29.6.1: with two identical power units and no auxiliary gear, a cargo ship must meet 28 s with ALL units operating; a passenger ship with any one unit stopped. Both feedback messages reworded to say so. The book (ch13) already says one pump may not meet 28 s.
confirmed: Each pump motor on its own circuit from the main board, one may be through the emergency board; no overload trip, overload and phase failure are alarms (Canada Marine Machinery Regulations SOR/90-264 Sch. VII Div. I item 18 (SOLAS II-1/30 wording), https://laws-lois.justice.gc.ca/eng/regulations/sor-90-264/page-9.html) Short-circuit protection plus overload alarm; phase-failure alarm.
confirmed: Tankers of 10,000 GT and up have extra single-failure rules (SOR/90-264 Sch. VII item 22) Steering regained within 45 s after a single failure.
Stored Energy and Arc Flash: Where It HidesChecked in part · 1 confirmed · 0 corrected · 3 not verified
confirmed: Drive DC bus about 620 V on 440 V (arithmetic re-worked) 440 x 1.414 = 622.
unverified: Arc flash label: arc-rated clothing and hood, 8 cal/cm2 minimum, rubber gloves, 1.4 m boundary (NFPA 70E (not reachable)) Declared a teaching label. No NFPA 70E article is quoted on the page.
unverified: Wait the drive's label time then meter the bus; never short a capacitor bank with a tool (maker practice)
unverified: Spring: rack out, close on its spring, open, read DISCHARGED. Drive: wait label time then meter. Motor: stop it turning, prove dead at the motor. Battery: pull the link, cover terminals, rings off, insulated tools (maker practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs. See the rack-out order note under lesson-acb-bus-tie.
unverified: Lamp colors: US and Japanese/Korean boards red = running, European machinery often green = running Trade convention; page already says check the legend.
Synchronizing and Load SharingChecked in part · 2 confirmed · 0 corrected · 3 not verified
confirmed: Four things match before closing: phase sequence, voltage, frequency, phase angle (46 CFR 111.30-25(d) requires synchroscope/lamps (USCG PRG E2-21); standard practice)
unverified: Check-sync window in the model: 4 % volts (17.6 V), 0.3 Hz, 20 degrees (none) Model values, not stated as a rule in the text. No rule source found for a fixed window.
unverified: Reverse power trips the slow incoming set at -35 kW after 2 s (27 kW setting) (46 CFR 111.12-11(f) (trip required, no figure); Wartsila 31 product guide https://www.manualslib.com/manual/1228139/Wartsila-31.html?page=133 ; ABB REG670 manual https://www.manualslib.com/manual/1283071/Abb-Reg670.html?page=389 ; secondary citing IEEE C37.102: https://relayprotect.com/generator-reverse-power-protection/) Teaching setting, left unchanged. 46 CFR only requires the trip. Wartsila: a diesel set can absorb max 5 % reverse power. ABB: motoring power about 15 % (5 % run-in to 25 % stiff), relay set well below it. Secondary citing IEEE C37.102: 5-15 % pickup, 2-10 s. Class-rule text (DNV Pt.4 Ch.8 / IEC 60092-202) was not reachable. 3 % / 2 s is below the Hawsepiper book's 5-15 % and below the published diesel range; consider moving the site to within 5-15 % with a few seconds delay.
confirmed: 310 kW each, 557 A and 467 A, pf figures (arithmetic re-worked) Consistent with kVA = 0.762 x A at 440 V.
unverified: Close just before 12 with the needle turning slowly clockwise (incoming set slightly fast); governors share kW, AVRs share kVAR; a droop CT reversed after an AVR change (standard practice; no primary source fetched) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Tanks and Soundings: The Tape DecidesChecked in part · 3 confirmed · 1 corrected · 1 not verified
corrected: VCF (ASTM Table 54B) at 45 °C for 0.9850: 0.9808 (API MPMS 11.1 / ASTM D1250 constants as tabulated at https://en.wikipedia.org/wiki/Volume_correction_factor (fuel oils K0 103.8720, K1 0.2701 at 60 °F; equivalent 15 °C set 186.9696, 0.4862) with VCF = exp(-a*dT*(1+0.8*a*dT)) (https://maritime-inky.vercel.app/astm-54b-vcf-calculator). Both constant sets give 0.9793.) Changed to 0.9793. Worked example re-run: 98.0 x 0.9793 = 96.0 m³ (was 96.1); metric tons in air 94.4 t (was 94.6); density-alone figure 94.5 (was 94.7); wrong-answer options changed to match (100.1 m³, 96.0 t). The page's own '0.07 % a degree' also gives 0.979.
unverified: Metric tons in air = volume at 15 °C x (density at 15 °C - 0.0011) (ASTM D1250 Table 56 air-buoyancy convention; not fetched) Standard bunker-survey practice.
confirmed: 112 cm, 2.0 m trim: 101.6 - 3.6 = 98.0 m³ (arithmetic checked)
confirmed: Residual fuel volume change about 0.07 % per °C (API MPMS 11.1 / ASTM D1250 constants as tabulated at https://en.wikipedia.org/wiki/Volume_correction_factor (fuel oils K0 103.8720, K1 0.2701 at 60 °F; equivalent 15 °C set 186.9696, 0.4862) with VCF = exp(-a*dT*(1+0.8*a*dT)) (https://maritime-inky.vercel.app/astm-54b-vcf-calculator). Both constant sets give 0.9793.) alpha = 0.000686 per °C for 985 kg/m³.
Ten QuestionsChecked · 2 confirmed · 0 corrected · 0 not verified
confirmed: 1,225 kW on two 900 kW sets is 68% each (Arithmetic re-computed by the auditor)
confirmed: Emergency board back inside 45 seconds (SOLAS II-1/43.3.1 ('subject to a maximum of 45 seconds'), text at https://wetten-overheid.nl/wet/BWBV0003264/artikel/43)
The 45 SecondsChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: Emergency generator must start and take the emergency board within 45 seconds, without a person (SOLAS II-1/43.3.1 ('subject to a maximum of 45 seconds'), text at https://wetten-overheid.nl/wet/BWBV0003264/artikel/43)
unverified: Emergency lighting dark until the emergency generator is on (no transitional battery); steering pump restarts by itself when power returns (SOLAS II-1/43.3.1 and II-1/29.8 (29 not fetched)) Reg. 43 needs a transitional source only where the generator is not auto-started within 45 s, so no battery is consistent. Automatic steering restart matches II-1/29 as the auditor knows it; not fetched.
The 4–20 mA Loop: Read It, Find the Break, Prove ItChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: Failed transmitters park outside 4-20 mA; 3.6 mA fault point (NAMUR NE43 as given by Beckhoff: https://infosys.beckhoff.com/content/1033/el31xx/4009211275.html) NE43: failure at or below 3.6 mA or at or above 21 mA.
confirmed: 3.5 bar = 9.6 mA; 14.9/20 x 120 = 89.6; 13.1 - 10.4 = 2.7 mA (arithmetic re-worked) 89.6 needs the unrounded 14.93 mA; 14.9 gives 89.4. Left as is.
unverified: Half-split an open loop with volts across the pair, not mA in series; prove a repair by simulating 4, 12 and 20 mA from the field end (standard instrument practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
The Alarm Is a SymptomChecked · 2 confirmed · 0 corrected · 0 not verified
confirmed: 310 kW is about a third of 900 kW (arithmetic recomputed)
confirmed: A false alarm leaves that point unwatched until fixed: tell the duty engineer and log it (read in full on the second pass; procedure or ownership rule, no outside standard applies)
The Alarm System as a MapChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: 4 + 3.5 x 1.6 = 9.6 mA (arithmetic recomputed)
confirmed: PT100 is 100 ohm at 0 C (Okazaki Pt100 table to IEC 60751:2008 (100.00 ohm at 0 C, 138.51 at 100 C), https://okazaki.media-tec.jp/en/Tech_info/resistance_thermometer_table.html)
unverified: Unanswered alarm goes on to the engineers' alarm after a set time (three minutes here) (SOLAS II-1/51 (not fetched)) The three minutes is a ship setting, a teaching value.
The Alternator in One Line: Two Loops, Three Machines and a BoxChecked in part · 2 confirmed · 0 corrected · 2 not verified
confirmed: Megger the stator at 500 V DC, one minute per phase (IEEE 43-2013 via two secondary summaries (primary text paywalled): https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums ; https://reliamag.com/articles/insulation-testing-ieee-standards-43-and-p97/)
confirmed: 220 V x 2.3 A = about 500 W; 300 kW / 225 kVAR (arithmetic re-worked)
unverified: Never megger through the AVR (maker practice)
unverified: Megger order: rack out and lock, block the start, prove dead, lift AVR sensing leads and unplug the AVR, test, discharge each phase to frame, refit (alternator makers' practice, not fetched) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
The Battery RegisterChecked · 1 confirmed · 0 corrected · 0 not verified
confirmed: Float about 13.5 V a block; a bank on float always draws a little (East Penn AVR45/HT45 manual: float 2.25 V/cell, equalize 2.40 V/cell, end voltage 1.75 V/cell at 25 C https://www.eastpennmanufacturing.com/wp-content/uploads/AVR45-HT45-Single-Cell-Railway-Utility-IO-2727.pdf)
The Bow ThrusterChecked · 8 confirmed · 0 corrected · 0 not verified
confirmed: 3 x 1,476 = 4,428 A; six times 940 A is 5,640 A (arithmetic recomputed)
confirmed: 65% tap gives about 42% of line start current (arithmetic recomputed)
confirmed: 400 W heater at 220 V draws about 1.8 A (arithmetic recomputed)
confirmed: Half speed on a fixed-pitch propeller is an eighth of the power, about 75 kW (arithmetic recomputed)
confirmed: 760 kW plus the thruster is 465 kW a set (52%); on two sets 698 kW (78%) (arithmetic recomputed) Uses the lesson's 630 kW drive input.
confirmed: Bus drops to about 350 V, 'a fifth' (arithmetic recomputed) 440 to 350 V is 20%.
confirmed: Never megger through a drive; lift the motor cables at the drive; wait for the DC bus and prove dead; lock off the heater's separate supply too (read in full on the second pass; procedure or ownership rule, no outside standard applies; drive standstill hazard noted in ABB Standard LV Motors Manual (2009 Rev D), https://library.e.abb.com/public/e20ddd6a89ed4815821e8163f569bf63/Standard_LV_Motors_Manual_EN_01_2009%20Rev%20D.pdf)
confirmed: The start permit is never jumpered (read in full on the second pass; procedure or ownership rule, no outside standard applies)
The Control SchematicChecked in part · 0 confirmed · 0 corrected · 1 not verified
unverified: Contacts drawn de-energized; Hand does not bypass the trip relay or overload; find the cause before pressing TRIP RESET (drawing convention; teaching circuit) Self-consistent with the drawn circuit.
The Emergency Generator ChainChecked in part · 5 confirmed · 1 corrected · 1 not verified
confirmed: Emergency generator must start and take the emergency board within 45 seconds automatically (SOLAS II-1/43-44 as implemented in IoM Merchant Shipping (Cargo Ship Construction) Regs 1998, Sch. 10: https://www.iomshipregistry.com/media/2221/sd603-98-ms-cargo-ship-construction-regulations-1998.pdf) Sch. 10 para 1(g)(ii): services supplied within 45 seconds.
confirmed: Cargo ships: full blackout until the set closes on; passenger ships and some cargo ships carry a battery (transitional source) (SOLAS II-1/43-44 as implemented in IoM Merchant Shipping (Cargo Ship Construction) Regs 1998, Sch. 10: https://www.iomshipregistry.com/media/2221/sd603-98-ms-cargo-ship-construction-regulations-1998.pdf) Transitional battery (30 min) needed on a cargo ship only when the set does not auto-connect in 45 s.
confirmed: Emergency board loads: lighting, one steering motor, emergency fire pump, fire detection, radio/navigation, watertight doors, chargers (SOLAS II-1/43-44 as implemented in IoM Merchant Shipping (Cargo Ship Construction) Regs 1998, Sch. 10: https://www.iomshipregistry.com/media/2221/sd603-98-ms-cargo-ship-construction-regulations-1998.pdf) All appear in the service list (doors 30 min; lights, nav lights, radio, fire detection, fire pump 18 h). Emergency air compressor is ship-specific.
confirmed: Two independent ways to start; second starting means is required (SOLAS II-1/43-44 as implemented in IoM Merchant Shipping (Cargo Ship Construction) Regs 1998, Sch. 10: https://www.iomshipregistry.com/media/2221/sd603-98-ms-cargo-ship-construction-regulations-1998.pdf) Rule wording: second source of stored energy for three more starts within 30 min, unless manual starting is shown effective.
confirmed: Weekly visit / weekly run (46 CFR 97.15-30: https://www.law.cornell.edu/cfr/text/46/97.15-30) 97.15-30(a): operated and inspected at least weekly.
corrected: Load test 'on the SMS schedule' (the lesson runs it 5 minutes) (46 CFR 97.15-30(b): https://www.law.cornell.edu/cfr/text/46/97.15-30) Added one sentence after 'never skipped': US-flag cargo ships must also run the emergency generator under load for at least 2 hours every month the ship is navigated (46 CFR 97.15-30(b)). Rebuilt; chk.py clean.
unverified: Interlock: tie and EDG breaker cannot both be closed unless a synchronizer is fitted; test by opening the tie with the bridge warned and the Chief agreeing (ship practice) Consistent with the SOLAS arrangement (interconnector disconnects on main failure); wording is ship practice.
The Fire Detection Panel: Loops, Addresses, InterlocksChecked in part · 6 confirmed · 0 corrected · 1 not verified
confirmed: Two power feeds, one from the main and one from the emergency switchboard, each reserved for the fire system (FSS Code ch. 9, 2.2.1-2.2.5, 2.1.6, 2.5.1.5 (full text at https://puc.overheid.nl/nsi/doc/PUC_2394_14/8/ and IACS UI SC35 https://www.turkloydu.org/pdf-files/iacs-karar-ve-csr-degisimleri/iacs-es-yorumlari/UI_SC35.pdf))
confirmed: A battery carries the panel through the changeover gap (FSS Code ch. 9, 2.2.1-2.2.5, 2.1.6, 2.5.1.5 (full text at https://puc.overheid.nl/nsi/doc/PUC_2394_14/8/ and IACS UI SC35 https://www.turkloydu.org/pdf-files/iacs-karar-ve-csr-degisimleri/iacs-es-yorumlari/UI_SC35.pdf)) FSS 9/2.2.2: battery of adequate capacity for continuous operation during changeover.
confirmed: Loss of a feed or a loop fault raises a fault signal (FSS Code ch. 9, 2.2.1-2.2.5, 2.1.6, 2.5.1.5 (full text at https://puc.overheid.nl/nsi/doc/PUC_2394_14/8/ and IACS UI SC35 https://www.turkloydu.org/pdf-files/iacs-karar-ve-csr-degisimleri/iacs-es-yorumlari/UI_SC35.pdf)) FSS 9/2.5.1.5: supplies and circuits monitored; fault gives visual and audible signal.
confirmed: Addressable loop: a short loses only the stretch between isolators; one open loses nothing (FSS Code ch. 9, 2.2.1-2.2.5, 2.1.6, 2.5.1.5 (full text at https://puc.overheid.nl/nsi/doc/PUC_2394_14/8/ and IACS UI SC35 https://www.turkloydu.org/pdf-files/iacs-karar-ve-csr-degisimleri/iacs-es-yorumlari/UI_SC35.pdf)) FSS 9/2.1.6: a fault in the section must not prevent identification of the remaining detectors.
confirmed: CO2 is never released automatically by the fire panel; a person releases it at its own cabinet (FSS Code ch. 5, 2.1.3.4 and 2.2.2 (https://puc.overheid.nl/nsi/doc/PUC_2394_14/8/ ; IACS UI SC132)) FSS 5/2.1.3.4: automatic release not permitted (except as permitted by the Administration); two separate controls in a release box.
confirmed: 17 Ah / 0.6 A is about 28 h (Arithmetic re-computed by the auditor)
unverified: A zone is disabled only while someone is working on it, logged, and enabled after; panel in fault means fire patrols (Company SMS practice; SOLAS II-2/7 (not fetched)) Sound practice, no primary text fetched.
The Frequency Meter Test: Which Loop Is SickChecked in part · 3 confirmed · 0 corrected · 1 not verified
unverified: Flash a field with 12 V through a diode for about three seconds, field leads off the AVR (Stamford alternator fault finding manual (2002), section 4 'Loss of residual voltage', https://dieselduck.ca/machine/03%20electricity/2002%20Stamford%20Alternator%20fault%20finding%20Manual.pdf; ETO book 2.2) Makers differ. Stamford: set running at rated speed, no load, 12 V battery with a blocking diode in one lead onto X+ (F1) and XX- (F2), 'Maximum connection time 1 second', and never a battery on the AVR terminals without the diode. The lesson says about three seconds with the field leads off the AVR (ETO 2.2, which also says the maker's manual wins; the lesson leaves that sentence out). A Leroy-Somer manual could not be opened. Not changed; suggest adding 'the maker's manual wins' to the lesson.
confirmed: A set with a PMG does not need residual magnetism; a long layup can lose it on a set without one (Stamford alternator fault finding manual (2002), section 4 'Loss of residual voltage', https://dieselduck.ca/machine/03%20electricity/2002%20Stamford%20Alternator%20fault%20finding%20Manual.pdf) Stamford lists years of storage as a cause and says PMG systems do not rely on residual voltage.
confirmed: Rotating diodes: tested stopped, in diode mode, a reading one way and open the other (Stamford alternator fault finding manual (2002), section 4 'Loss of residual voltage', https://dieselduck.ca/machine/03%20electricity/2002%20Stamford%20Alternator%20fault%20finding%20Manual.pdf) Stamford: leads disconnected; a faulty diode reads both ways or neither; replace the full set.
confirmed: Governor settings are the Chief's; the electrician checks pickup, actuator wiring and governor box, then hands over (read in full on the second pass; procedure or ownership rule, no outside standard applies)
The GalleyChecked in part · 4 confirmed · 0 corrected · 1 not verified
confirmed: Two 150 Ω elements on 440 V: series 300 Ω, parallel 75 Ω, four times the heat low to high (arithmetic checked) 645 W / 1,291 W / 2,581 W.
confirmed: Dishwasher final rinse must be 82 °C or above to sanitize (https://www.law.cornell.edu/regulations/minnesota/Minn-R-4626-0795 (adopts FDA Food Code 4-501.112: 180 °F / 82 °C at the manifold))
confirmed: Booster 35 °C in + 36 °C rise = 71 °C (arithmetic checked)
unverified: Fryer oil 160-190 °C; high limit never set above 230 °C (EN 60335-2-37 / UL 197 not reached) Safety figure not verified against a standard; maker's manual governs.
confirmed: GFCI: a breaker that trips when current leaks to the hull (https://www.thebuildingcodeforum.com/forum/threads/understanding-class-a-gfcis-what-inspectors-need-to-know.38201 (UL 943 Class A 4-6 mA; secondary))
The Induction Motor: Slip, Starting Current, TorqueChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: Synchronous speed 120 f / poles; torque with voltage squared; pump power with speed cubed (1.73) (arithmetic re-worked) Standard formulas; all worked figures re-checked.
unverified: Start current six to eight times plate (book figure) Typical; not checked against NEMA/IEC.
confirmed: 10 % off the volts is 19 % off the torque, 20 % is 36 %; wye-delta gives a third of the current and a third of the torque; repeated starts overheat the motor (arithmetic re-worked) 0.9 squared = 0.81; 0.8 squared = 0.64; (1/1.732) squared = 1/3.
The LaundryChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: GFCI trips at about 5 mA (https://www.thebuildingcodeforum.com/forum/threads/understanding-class-a-gfcis-what-inspectors-need-to-know.38201 (UL 943 Class A 4-6 mA; secondary)) UL 943 Class A: must trip at 6 mA, must not trip below 4 mA.
unverified: TEST every GFCI monthly (maker instructions / UL 943 marking; not fetched)
confirmed: 12 kΩ to frame leaks about 10 mA on the 220 V system (arithmetic checked) 220/√3 = 127 V to hull; 127/12,000 = 10.6 mA. (On a truly insulated system the leak also depends on the other phases' leakage; teaching model.)
The Loop DrawingChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: 1.6 mA per bar on 0-10 bar; 2.40 V / 250 ohm = 9.6 mA; 0-16 bar transmitter gives 7.5 mA read as 2.2 bar (arithmetic re-worked)
unverified: Tell the watch before opening a loop link; test terminals and the 250 ohm resistor read without opening the loop (practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
The Main Board One-LineChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: Megger at 500 V on 440 V cable sections (IEEE 43-2013 via two secondary summaries (primary text paywalled): https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums ; https://reliamag.com/articles/insulation-testing-ieee-standards-43-and-p97/) About 500 V DC for windings at or below 1 kV.
unverified: Feeder trip is a fault downstream until proven otherwise: lock out, walk the cable, megger in sections before re-closing; both sides of an open tie are live (book practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
The Megger LogChecked · 2 confirmed · 1 corrected · 0 not verified
confirmed: Insulation resistance roughly halves for every 10 C warmer (Fluke on IEEE 43 temperature correction https://www.fluke.com/en-us/learn/blog/insulation-testers/use-insulation-resistance-testing-data-to-avert-unexpected-downtime)
corrected: Readings above 2 megohms called 'legal' (body.js twice, meta.json lede) (Book ETO 1.10: two megohms is the book's own working line; it quotes kV+1 (about 1.5 megohm) as the old rule and 5 megohm from the current IEEE guide) Reworded: 'over the book's working floor of 2 megohms (its own line, not a legal limit)', 'still over the floor', and the lede likewise. IEEE 43 itself was not reachable. Rebuilt and chk clean.
confirmed: 22 halving each quarter: 11, 5.5, 2.75 (under 3 by August) (Arithmetic re-computed by the auditor)
The MeterChecked in part · 3 confirmed · 1 corrected · 1 not verified
confirmed: Megger at 500 V for a 440 V motor (IEEE 43 summary, https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums (secondary))
corrected: Prove dead: isolate, lock, prove tester, test every conductor to every other and to hull, prove tester again, then stored energy (NFPA 70E 120.5 as reproduced at https://e2g.com/?p=21776 and https://expertce.com/learn-articles/how-to-establish-electrically-safe-work-condition/ (two secondary; the standard is paywalled)) Old order: lock, prove tester, test, prove tester, then stored energy. New: lock, deal with stored energy, prove tester, test, prove tester (step list, the reason text and the closing line in src/the-meter.html). Both sources put stored-energy release before the absence-of-voltage test. They differ on whether it comes before or after the lock (e2g, closest to the standard's wording: release, then lock); the page keeps lock first
confirmed: CAT III 600 V or better for a 440 V switchboard (GAMBICA Guide to Overvoltage Categories and Measurement Categories (IEC 61010), https://www.gambica.org.uk/static/d96bb734-348d-478e-b0cba3b50fc35940/Guide-to-Overvoltage-Categories-and-Measurement-Categories.pdf) CAT III covers distribution boards, breakers, busbars and fixed motors; CAT IV is between the supply source and the first isolator
confirmed: 50 A through 0.15 ohm = 7.5 V and 375 W (arithmetic checked by hand)
unverified: Meter input about 10 MOhm, LoZ about 3 kOhm, mA fuse about 400 mA, diode 0.4-0.7 V (no primary source reached this session; not changed) Typical maker figures
The Nameplate and the OverloadChecked in part · 8 confirmed · 0 corrected · 2 not verified
confirmed: Class F insulation is 155 C (WEG motor specification guide, Table 1.5 citing IEC 60085, https://www.wolfautomation.com/content/weg-electric-motors-specguide.pdf) Class F = 155 C (B 130, H 180).
unverified: IP55: dust and water jets (WEG general purpose technical catalog, https://static.weg.net/medias/downloadcenter/h21/h17/WEG-WMO-weg-general-purpose-technical-catalogue-50130072-brochure.pdf ('IP55 - protection against water and dust'); IEC 60529 digit table not reached) Dust and water confirmed by the maker; the word 'jets' for the second digit was not quoted by any source reached. Not changed.
confirmed: 1765 rpm is 35 rpm under 1800, the 60 Hz four-pole speed; on 50 Hz about a sixth slower (WEG motor specification guide, Table 1.5 citing IEC 60085, https://www.wolfautomation.com/content/weg-electric-motors-specguide.pdf (ns = 120 f / poles: 1,800 rpm for 4 poles at 60 Hz); arithmetic recomputed)
confirmed: 440 delta / 760 wye; 37.0 A delta, 21.4 A wye; wye on 440 V gives 254 V per winding and a third of the torque; wye motor in delta gets 1.7 x volts (arithmetic recomputed)
confirmed: Frame 180 means shaft center 180 mm off the feet; frame 180 four-pole is 22 kW within one step (ABB General Performance Motors catalog (H = 180; 18.5 and 22 kW in frame 180 at 4 poles), https://library.e.abb.com/public/4721a2aae978d79bc1257b1300570ff6/Catalogue_General%20Performance%20Motors%20EN%2004_2008%20RevB.pdf)
confirmed: Trip class 10 for a start of a few seconds, 20 for a long start, 30 for the hardest (IEC 60947-4-1 trip class table in ABB catalog, https://resources.ipd.com.au/Flipbook/Contactor/files/basic-html/page989.html) At 7.2 x setting: class 10 trips in 4-10 s, 20 in 6-20 s, 30 in 9-30 s.
unverified: Dial at plate amps; times the service factor (50 x 1.15 = 57.5 A) on a motor allowed to run over (Schneider FAQ000278064 (TeSys LRD), https://www.se.com/us/en/faqs/FAQ000278064/ ; Rockwell 193-IN083, https://literature.rockwellautomation.com/idc/groups/literature/documents/in/193-in083_-en-e.pdf) Both makers recorded. Schneider: the dial is the motor's nominal current (FLA); NEC 430.32 allows up to 125% of FLA for service factor 1.15 or more and 115% otherwise, with worked examples of a 10 A motor set at 12.5 A (SF 1.15) and 11.5 A (SF 1.0). Rockwell: 'Trip rating is 120% of dial setting'; its diagram shows '1 x FLA' and '0.9 x FLA' against service factor above and below 1.15 (the extraction was garbled, so which is which was not confirmed). The book's FLA x SF (57.5 A on 50 A) is inside the NEC ceiling, but on a relay that trips at 120% of the dial it trips near 69 A, 138% of FLA. Left as the book has it; suspected erratum for ETO 4.6.
confirmed: AC-3 is the motor rating, AC-1 the resistive rating (IEC/EN 60947-4-1 categories as listed by Lovato Electric, https://academy.lovatoelectric.com/faq-items/what-is-the-utilization-category-of-a-contactor/?lang=en) AC-1: non-inductive or slightly inductive loads. AC-3: squirrel-cage motors, starting and switching off while running.
confirmed: 18.5 and 22 kW four-pole motors are frame 180 (M and L) (WEG general purpose technical catalog, https://static.weg.net/medias/downloadcenter/h21/h17/WEG-WMO-weg-general-purpose-technical-catalogue-50130072-brochure.pdf)
confirmed: Never raise the dial to cure a trip; automatic reset restarts a two-wire motor by itself (read in full on the second pass; procedure or ownership rule, no outside standard applies)
The Nav Sensors and the Feeds Between ThemChecked in part · 2 confirmed · 0 corrected · 3 not verified
confirmed: NMEA sentences at 4800 baud; AIS at 38,400 baud; AIS sentences start with ! not $ (NMEA 0183 summary https://handwiki.org/wiki/NMEA_0183 (secondary; the standard itself is paywalled))
confirmed: Checksums on all six example sentences (GGA x2, RMC, HDT, VBW, DPT) (Arithmetic re-computed by the auditor) XOR of characters between $ and * recomputed: all six match
unverified: Talker and sentence meanings: GP GPS, HE north-seeking gyro, VD Doppler log, SD sounder, AI AIS; GGA quality 1 = fix, 0 = no fix; DPT offset positive = transducer to waterline; RMC status V = not valid; VDO own ship, VDM others (NMEA 0183 / IEC 61162-1 (paywalled)) Matches the standard as the auditor knows it, but no primary text was reachable this session; the secondary page fetched did not list these fields.
unverified: GPS receiver feeds 5 V DC up the antenna cable (n/a) Teaching value; real receivers use 3.3 to 5 V typically.
unverified: The forward void is an enclosed space: entry permit, atmosphere tested, standby man (IMO Res. A.1050(27) (not fetched)) Correct practice; text not fetched.
The Radar as Blocks: Scanner, Magnetron and InputsChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: Radio waves about 300 m per microsecond; 1 nm = 1,852 m; out and back 3,704 m is about 12.4 us; 74 us is about 6.0 nm (Arithmetic re-computed by the auditor) 3704/299.79 = 12.36 us; 74/12.36 = 5.99 nm
confirmed: 24 rpm antenna: one turn in 2.5 s (Arithmetic re-computed by the auditor)
confirmed: 8,590 - 600 = 7,990 transmit hours (Arithmetic re-computed by the auditor)
unverified: Magnetron life to plan for: about 8,000 hours (Page attributes it to 'this set's manual') Teaching value attributed to an invented manual; real makers' figures vary by tube. Not checked.
The Ship’s NetworksChecked · 2 confirmed · 0 corrected · 0 not verified
confirmed: RS-485: a 120 ohm resistor across A and B at each end only; 60 ohm for two, 40 ohm for three, 120 ohm for one (Texas Instruments RS-485 guide (120 ohm, one at each cable end), https://erg.abdn.ac.uk/users/Gorry/eg3576/resources/RS485-intro-TI.pdf ; arithmetic recomputed)
confirmed: Fiber: -5 dBm in, -26 dBm out is 21 dB lost (arithmetic recomputed)
The Synchronous Machine: Two Sets of RulesChecked in part · 1 confirmed · 0 corrected · 1 not verified
unverified: Reverse power 27 kW for 2 s (46 CFR 111.12-11(f) (trip required, no figure); Wartsila 31 product guide https://www.manualslib.com/manual/1228139/Wartsila-31.html?page=133 ; ABB REG670 manual https://www.manualslib.com/manual/1283071/Abb-Reg670.html?page=389 ; secondary citing IEEE C37.102: https://relayprotect.com/generator-reverse-power-protection/) Teaching setting, left unchanged. 46 CFR only requires the trip. Wartsila: a diesel set can absorb max 5 % reverse power. ABB: motoring power about 15 % (5 % run-in to 25 % stiff), relay set well below it. Secondary citing IEEE C37.102: 5-15 % pickup, 2-10 s. Class-rule text (DNV Pt.4 Ch.8 / IEC 60092-202) was not reachable. 3 % / 2 s is below the Hawsepiper book's 5-15 % and below the published diesel range; consider moving the site to within 5-15 % with a few seconds delay.
confirmed: 620 kW / 465 kVAR and 300 kW / 225 kVAR at 0.8 pf (arithmetic re-worked)
The System Wiring DiagramChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: Never open a CT secondary on load; short it first (8 CCR 2940.18(a) (Cal/OSHA; mirrors 29 CFR 1910.269): https://www.dir.ca.gov/title8/2940_18.html)
confirmed: 1,500/5 CT gives about 3.3 A at 1,000 A (arithmetic re-worked)
unverified: Drawings show contacts at rest; 52a takes the trip coil out once the breaker opens; PT fuse first for a dead meter or relay (standard drawing convention) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
The Ungrounded System: The Ground That Waited a WeekChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: 254 V / 0.1 ohm = 2,540 A; 55 mA per lamp; 1.4 uF a line leaks 0.4 A; 440 V / 0.15 ohm = 2,900 A (arithmetic re-worked)
confirmed: With one phase grounded the other two sit at 440 V to hull (physics)
unverified: Ungrounded does not mean safe to touch one phase; never inhibit the insulation alarm; one ground is a job for today (book practice; physics checked in the arithmetic) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
The VFD from the OutsideChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: DC bus is 440 x 1.41 = about 620 V (arithmetic recomputed)
confirmed: Half speed on a fan is about an eighth of the power (arithmetic recomputed (cube law))
unverified: Wait for the bus to discharge (label: 10 min), then prove with a meter (drive maker's label) Teaching label; real wait time is the maker's.
confirmed: Rotation on a drive is changed at the motor leads, not the supply (physics: the rectifier removes phase sequence)
confirmed: 254 V x 1.732 = 440 V; 440 V rms peaks at 622 V; 16.7 ms cycle, 5.6 ms between phases; P = 1.732 V I pf; about 1.5 A per kW at 440 V 0.85 pf; wye start = one third current and torque (arithmetic checked by hand)
confirmed: Two-stroke: exhaust valve 110 to 250, ports 140 to 220 (symmetric about BDC), injection 356 to 376; four-stroke: EVO 130, EVC 415, IVO 300, IVC 575, injection 710; overlap 300 to 415 = 115 degrees, i.e. 60 before to 55 after overlap TDC (arithmetic) All stated angles agree with the event table. The values themselves are labeled 'typical timing for teaching'; no maker figure claimed.
Transformers and the 220 V SideChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: 150 kVA: 197 A at 440 V, 394 A at 220 V; 430 A = 109 %; 430 A secondary = 215 A primary (arithmetic re-worked)
unverified: Lock out both breakers and prove dead on primary and secondary: a transformer can be back-fed from either side (standard isolation practice) No rule or maker text found that contradicts it; generic practice, maker's manual governs.
Transmitters and SwitchesChecked · 1 confirmed · 0 corrected · 0 not verified
confirmed: A drained wet reference leg makes a DP cell read the drum fuller than it is (physics: less head on the reference side lowers the differential)
Troubleshoot a Battery ChargerChecked · 3 confirmed · 0 corrected · 0 not verified
confirmed: Float 27.2 V, boost 28.1 V; book's typical float 2.25 V a cell = 27.0 V (East Penn AVR45/HT45 manual: float 2.25 V/cell, equalize 2.40 V/cell, end voltage 1.75 V/cell at 25 C https://www.eastpennmanufacturing.com/wp-content/uploads/AVR45-HT45-Single-Cell-Railway-Utility-IO-2727.pdf)
confirmed: 9.0 A for about 4 h = 36 Ah; 1.1 V x 9.6 A is about 10 W; 20 A = 9.0 + 11.0 (Arithmetic re-computed by the auditor)
confirmed: 30 V AC through a bridge gives about 40 V of rough DC (peak) (Arithmetic re-computed by the auditor) 30 x 1.414 = 42.4 V peak less two diode drops.
Two-Stage Air CompressorChecked in part · 1 confirmed · 0 corrected · 1 not verified
confirmed: Normal readings at 28 bar receiver: intercooler 4.5 bar, LP discharge 177 C, HP discharge 184 C; 'intercooler around 4 to 5 bar' (arithmetic (model ported and rerun: 5:1 volumes, n = 1.3)) T2 = T1 x r^(0.3/1.3) used correctly. Fault directions (LP valve leak lowers, HP valve leak raises intercooler pressure) follow from the model.
unverified: High HP discharge temperature can ignite carried-over lube oil; drain separators Standard safety teaching; not source-checked.
UPS Systems: Online, Line-Interactive, BypassChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: 3 kVA / 2.4 kW; loads sum to 1.8 kW (1.4 kW without CCTV); runtime model gives about 22 min at 1.8 kW with battery at 60% (Arithmetic re-computed by the auditor) 60 x 0.6 x (1.2/1.8)^1.25 = 21.7 min
confirmed: 8 x 12 V string: 108 V float is 13.5 V a block; 84 V is 10.5 V a block (1.75 V a cell), the end voltage (East Penn AVR45/HT45 manual: float 2.25 V/cell, equalize 2.40 V/cell, end voltage 1.75 V/cell at 25 C https://www.eastpennmanufacturing.com/wp-content/uploads/AVR45-HT45-Single-Cell-Railway-Utility-IO-2727.pdf)
unverified: Online (double-conversion) UPS: load always on the inverter; static switch transfers to bypass in a few milliseconds (IEC 62040-3 (not fetched)) Standard description; no primary source fetched.
Using a MeterChecked in part · 5 confirmed · 0 corrected · 1 not verified
confirmed: CAT III 600 V minimum for switchboard and starters; CAT IV at the source (https://www.fluke.com/en-gb/learn/blog/safety/safe-test-tools-real-world-use) Fluke/IEC 61010: CAT III = three-phase distribution, switchgear, polyphase motors; CAT IV = utility connection/service entrance. 'Generator terminals' as CAT IV is the ship analog; the leads-count statement was not in the fetched page.
confirmed: Megger 500 V DC for 440 V motors and cables (https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums (summarizes IEEE 43; secondary)) IEEE 43: windings rated up to 1 kV, 500 V DC.
unverified: Under 2 MΩ a motor does not run until dried; over 100 MΩ dry and clean (https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums (summarizes IEEE 43; secondary)) IEEE 43 minimum for random-wound stators under 1 kV is 5 MΩ at 40 °C (older rule kV + 1 = about 1.4 MΩ). The 2 MΩ line is the ETO book's ship rule; not changed here. Worth Justin's eye, and should match lesson-megger-dry-out.
confirmed: 440 V insulated system: phase to hull about 250 V (440/√3 = 254 V) (arithmetic checked)
confirmed: LT1 35 A running on 37 A plate; coil 60 Ω; FU3 2 A (teaching values, self-consistent)
confirmed: Clamp all three phases together reads zero (physics (balanced three-wire currents sum to zero))
Valves: Open, Shut, and HoldingChecked in part · 1 confirmed · 0 corrected · 2 not verified
unverified: Handwheel clockwise to close; OS&Y stem out is open; quarter-turn handle across the pipe is shut (general valve practice; no standard fetched)
unverified: Centrifugal pump throttled on discharge, never suction (general pump practice; not fetched)
confirmed: Numbers: SWP1 2.2 / 2.0 bar, 1.9 bar held on the casing (teaching values, self-consistent)
Variable Frequency DriveChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: DC bus: 440 x root 2 = about 620 V no load, about 594 V running; 440/60 = 7.3 V/Hz; 4 kHz = 67 pulses per 60 Hz cycle; 5th = 300 Hz, 7th = 420 Hz (arithmetic checked by hand) 1.35 x 440 = 594
confirmed: Pump laws: 80% speed = about half power; 10% overspeed = 33% more power; 66 Hz asks 40 kW of a 30 kW motor (arithmetic checked by hand)
confirmed: Most class societies limit voltage THD on the main bus to around 8% (IACS UR E24 Rev.1, https://turkloydu.org/pdf-files/iacs-karar-ve-csr-degisimleri/iacs-es-gereklilikleri/UR_E24_Rev1_TR_EN.pdf) UR E24: THD not to exceed 8% unless equipment is designed for more
unverified: Never megger a motor or cable with the drive connected; wait the label discharge time and measure the DC bus (no primary source reached this session; not changed) Universal drive-maker instruction; no single manual fetched
VDR, Nav Lights and the WhistleChecked in part · 4 confirmed · 0 corrected · 1 not verified
confirmed: Prolonged blast is four to six seconds (Rule 32) (COLREGs Rule 32(c), text at https://www.legislation.gov.uk/cy/uksi/1989/1798/schedule/part/D./made/data.xht)
confirmed: Making way: one prolonged blast at intervals of not more than 2 minutes; under way but stopped: two prolonged blasts about 2 seconds apart, not more than 2 minutes (Rule 35) (COLREGs Rule 35(a),(b), same source)
confirmed: On its battery the VDR only has to record bridge audio for about two hours (IMO MSC.333(90) 5.4.2 https://wwwcdn.imo.org/localresources/en/KnowledgeCentre/IndexofIMOResolutions/MSCResolutions/MSC.333(90).pdf)
confirmed: 60 W lamp at 220 V draws about 0.27 A (Arithmetic re-computed by the auditor)
unverified: The VDR's annual test is the maker's, and its certificate is asked for at inspections (SOLAS V/18.8 (not fetched)) Matches the annual performance test requirement as the auditor knows it; text not fetched.
Vocabulary: The Words on Day OneChecked in part · 3 confirmed · 0 corrected · 1 not verified
unverified: Contactor terminal numbering 13-14 NO, 21-22 NC, 95-96 / 97-98 overload, A1-A2 coil (IEC 60947 / EN 50005 convention; not fetched) Standard IEC numbering as far as I can tell; no source reached.
confirmed: CAT III 600 V or better for any 440 V starter or board (https://www.fluke.com/en-gb/learn/blog/safety/safe-test-tools-real-world-use)
confirmed: Megger puts 500 V DC on a dead motor or cable (https://open-exam-prep.com/study-guides/neta-ett-level-ii/insulation-resistance-testing/ir-test-voltages-ieee-43-minimums (summarizes IEEE 43; secondary))
confirmed: 24 V DC on float reads about 27 V (ship value (data/ship.json 27.2 V); 2.27 V/cell x 12 = 27.2 V)
Watertight Doors, Davits and the Boat BatteryChecked in part · 3 confirmed · 0 corrected · 2 not verified
confirmed: Bridge panel: red for open, green only when the door is fully closed; alarm sounds at the door when it is closed remotely (SOLAS II-1/13.7.1.6 and 13.8.2 as quoted in the Netherlands flag checklist https://puc.overheid.nl/doc/PUC_2185_14) SOLAS: red = fully open, green = fully closed, flashing red while closing remotely; alarm at least 5 s before and until closed. Page's 'red while it moves' agrees.
confirmed: 13.5 - 12.3 = 1.2 V across the open charging plug (Arithmetic re-computed by the auditor)
unverified: 12.3 V resting is about two-thirds charged; a good battery holds about 10 V or more while cranking (Battery makers' state-of-charge charts (not fetched)) Typical figures (12.2 V about 50%, 12.4 V about 75%; 9.6 V is the usual cranking test floor). Not fetched.
confirmed: Lifeboat battery charged from the ship through a plug that parts when the boat leaves (LSA Code 4.4.6.11 in IMO MSC.48(66) https://wwwcdn.imo.org/localresources/en/KnowledgeCentre/IndexofIMOResolutions/MSCResolutions/MSC.48(66).pdf) Code: recharging from ship's supply at not more than 50 V, able to be disconnected at the embarkation station. Page's 13.5 V plug on a lanyard fits.
unverified: Never bridge a limit or jumper a lift door lock; test the davit limit by hand, not by hoisting into it (Book rule ETO 7.10) Safety practice from the book, no regulation text. Note lesson-deck-cranes proves a repaired hoist limit by hoisting slowly into it with a hand on the E-stop: different gear, but the two lessons read differently.
Weld a Bracket, Cut a Seized NutChecked in part · 7 confirmed · 1 corrected · 6 not verified
confirmed: Acetylene never above 1 bar (15 psi) (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.253) 29 CFR 1910.253(a)(2): not above 15 psig.
confirmed: Acetylene cylinder valve about one turn, key left on; crack valves before fitting regulators; no oil or grease on oxygen; stand to the side (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.253) (b)(5)(iii)(K): not more than 1½ turns, preferably ¾; (b)(5)(ii)(P), (iii)(C), (b)(5)(i), (ii)(E).
corrected: Draw no more than about one-seventh of the acetylene cylinder per hour (https://prodcd.harrisproductsgroup.com/en/Resources/Knowledge-Center/Tech-Tips/Tech-Tips-OLD/What-is-the-1-7-acetylene-rule (cites CGA G-1 5.3.3.13)) Changed to 'about one-tenth ... (the old rule was one-seventh)'. CGA G-1 now gives 1/10 (some suppliers 1/15 continuous; ESAB still prints 1/7).
confirmed: Fire watch stays commonly 30 to 60 minutes after the work stops (https://safteng.net/how-long-should-fire-watches-keep-watch-after-hot-work-ends/ (OSHA 29 CFR 1910.252(a)(2)(iii)(B) 30 min; newer standards 1 h; secondary)) OSHA minimum 30 min; newer standards (NFPA 51B 2019) 1 h. OSHA and NFPA texts themselves were not reachable.
confirmed: 1/8 in E7018 90-150 A; E6010 75-135 A; all DCEP (https://www.bester.rapidwelding.com/files/Lincoln Stick Electrode Welding Guide.pdf (Lincoln Electric)) Lincoln: Jetweld LH-70 90-150 DC+, Excalibur 7018 85-150; Fleetweld 5P 75-130 DC+ (page says 135: within maker-to-maker spread, left). Lower part of the range for vertical/overhead.
unverified: Stainless 1/8 in 60-100 A (no maker chart with 309L reached)
confirmed: E7018 out about 4 hours picks up moisture; oven 120-150 °C; E6010/E6011 never in the oven (https://prodcd.lincolnelectric.com/en/Welding-and-Cutting-Resource-Center/Welding-How-Tos/Storing-and-Redrying-Electrodes) Lincoln: hold at 250-300 °F (120-150 °C); issue twice a shift; do not re-bake cellulosic rods.
confirmed: Flashback: torch oxygen off first, then acetylene, then cylinders (https://www.hse.gov.uk/PUBNS/indg297.pdf) HSE INDG297 (backfire): oxygen first, then fuel, then cylinder valves.
unverified: Ordinary shut-down: torch acetylene first, then oxygen (makers differ (some say oxygen first); HSE leaflet gives no order) Follow the torch maker's instructions.
unverified: Cutting to 25 mm: oxygen 2-3 bar, acetylene 0.3-0.5 bar (tip chart governs (page says so); not fetched)
unverified: Hoses: green oxygen, red acetylene (US practice) (CGA/RMA not fetched) HSE (UK/ISO practice) gives blue oxygen, red fuel gas; fine for a US ship but say so if the ship's hoses are blue.
confirmed: Fillet throat about 0.7 x leg; 1 A per thousandth of an inch (1/8 in = 125 A) (arithmetic checked)
unverified: Plasma air typically 5-6 bar (maker's manual; not fetched)
unverified: Oxy-acetylene cuts carbon steel only (standard welding text; not fetched)
Weld Test PositionsChecked in part · 4 confirmed · 0 corrected · 2 not verified
confirmed: A groove test also qualifies fillets in that position; 3G and 4G together cover all positions on plate (Iowa DOT IM 560 (welder qualification to AWS D1.5/D1.1), https://ia.iowadot.gov/erl/current/IM/content/560.htm) 3G: groove F,H,V + fillet F,H,V. 4G: groove F,OH + fillet F,H,OH. Both: all.
confirmed: Limited-thickness test plate is 3/8 in. (Iowa DOT IM 560) 3/8 in. plate qualifies up to 3/4 in.
unverified: 1/8 in. E7018 at 90 to 160 A (one state DOT procedure); DCEP; out of position 10 to 15% cooler; rod oven The Iowa DOT document fetched does not give amperage. Trade guidance, attributed on the page.
confirmed: Definitions of 1F-4F and 1G-4G (flat, horizontal, vertical, overhead) (Iowa DOT IM 560 position table) F, H, V, OH mapping consistent.
confirmed: Test plate: 3/8 in., 45 degree V (22.5 each plate), 1/4 in. root opening, backing strip (AWS forum (CWI quoting D1.1: 'The groove angle is 45 degrees, the root opening is 1/4 inch'), https://app.aws.org/forum/topic_show.pl?pid=268775 ; test-plate supplier spec https://vxb.com/products/welder-certification-test-plate-for-aws-d1-1-limit) Two secondary sources; D1.1 itself is paywalled.
unverified: Cap crown 1/8 in. at most (AWS D1.1 visual acceptance table (not reachable))
Welding Symbol BuilderChecked · 2 confirmed · 0 corrected · 0 not verified
confirmed: Weld-all-around is a circle and field weld a flag at the junction of arrow and reference line; contour symbols flat/convex/concave; finish letters G grinding, M machining, C chipping, H hammering, R rolling (Moran, Interpretation of Metal Fab Drawings ch. 1.05 (AWS A2.4 summary), https://workforce.libretexts.org/Bookshelves/Manufacturing/Interpretation_of_Metal_Fab_Drawings_(Moran)/01:_Chapters/1.05:_Supplementary_Welding_Symbols) Secondary source; AWS A2.4 itself is paywalled. A2.4 also has P (planishing) and U (unspecified), not offered on the page.
confirmed: Below the line is arrow side, above is other side; perpendicular leg of fillet, bevel and J always on the left; broken arrow points at the member to be prepared; size left of the symbol, length-pitch right with a dash; pitch is center to center; groove angle and root opening on the symbol; depth of bevel left; plug diameter left; tail holds the process (Miller Electric, 'How to read and understand weld symbols' and 'Deciphering weld symbols', https://www.millerwelds.com/resources/article-library/how-to-read-and-understand-weld-symbols) Maker's summary of AWS A2.4. Exact inside/outside placement of root opening vs groove angle is not spelled out there; the page footer already says that placement is simplified.
When to Stop, When to Call, How to Hand It OverChecked in part · 1 confirmed · 0 corrected · 1 not verified
unverified: The radar transceiver uses several thousand volts (radar makers' manuals (not fetched)) Not changed.
confirmed: Stop at sealed units, vendor programs and high-voltage compartments; call with readings (read in full on the second pass; procedure or ownership rule, no outside standard applies)
Windlass, Mooring Winches and Hatch CoversChecked in part · 3 confirmed · 0 corrected · 1 not verified
confirmed: 8 poles about 870 rpm, 4 poles about 1,750 rpm at 60 Hz (WEG motor specification guide, Table 1.5 citing IEC 60085, https://www.wolfautomation.com/content/weg-electric-motors-specguide.pdf (ns = 120 f / poles); arithmetic recomputed) Synchronous 900 and 1,800 rpm.
unverified: Two-speed motor: one overload per winding, each at its own plate amps (maker practice) Standard arrangement; not fetched.
confirmed: Never bypass or tie back a limit switch; a creeping drum is a stop-work fault (read in full on the second pass; procedure or ownership rule, no outside standard applies)
confirmed: Spring-set brake lifted by its coil when the motor is energized (physics of a fail-safe brake; teaching layout)
Wye-Delta StarterChecked in part · 2 confirmed · 0 corrected · 1 not verified
confirmed: Wye start: 1/root 3 voltage, one third current and torque; auto-transformer 65% tap gives 42% line current and torque (arithmetic checked by hand)
confirmed: Class F winding limit 155 C; class 30 heavy-start overload (https://weh.maritime.edu/EN-3111/references/nema-standards-for-electric-motors.pdf) 155 C confirmed; class 30 overload not checked
unverified: Korndorfer connection is a closed transition (no primary source reached this session; not changed)
confirmed: Start current about 6 x 61 A = 366 A; wye start a third = 122 A; torque 165% to 55% (arithmetic recomputed) Six-times figure is a teaching value; the thirds follow from sqrt3 x sqrt3.
confirmed: 440 / sqrt3 = 254 V per winding in wye (arithmetic recomputed)
confirmed: Kick under 3.5 x full load is about 210 A (arithmetic recomputed) 3.5 x 61 = 213.5
confirmed: Overload in the winding leads is set to 0.58 x full-load current (arithmetic recomputed (1/sqrt3 = 0.577); layout also shown in Rockwell 193-IN083 (wye-delta setting), https://literature.rockwellautomation.com/idc/groups/literature/documents/in/193-in083_-en-e.pdf)
confirmed: Open wye leg: two windings in series across one line, about 100 A, no starting torque (arithmetic recomputed) From the lesson's own 366 A delta start: 440 V / (2 x 2.08 ohm) = 106 A.
Your Own One-LineChecked · 1 confirmed · 0 corrected · 0 not verified
confirmed: Emergency board live again within 45 seconds (SOLAS II-1/43.3.1 ('subject to a maximum of 45 seconds'), text at https://wetten-overheid.nl/wet/BWBV0003264/artikel/43)