A.2Carrier PrimeLINE (69NT40-561-001 to 199): scroll generation

Slide the drawing sideways, or open it full size.
Carrier PrimeLINE, what changed
Figure A.2. Carrier PrimeLINE, what changedOpen full size

What changed. A scroll compressor in place of the reciprocating one. Capacity control by a digital unloader valve (DUV) instead of the SMV, and an electronic expansion valve (EEV) in place of the thermostatic one. An economizer circuit with its own economizer solenoid valve (ESV). The controller is still Micro-Link 3, and the unit phase contactors (PA, PB), evaporator fan contactors (EF, ES), condenser fan contactor (CF) and heater contactor (HR) are all on the sheet.

Where things moved. New on the legend: DUV, EEV, ESV, a suction pressure transducer (SPT), evaporator temperature sensors (ETS) and a compressor discharge temperature sensor (CPDS). Supply, return, defrost and ambient sensors carry the same codes as on the ThinLINE.

Before you start. Read the controller's software version and write it down with the model number.

All of Appendix A