What changed. A variable-speed scroll compressor run by a 12 kW variable frequency drive (VFD), fed through the compressor contactor (CH) and taking its commands from the controller over a data link, so capacity is set by compressor speed. An EEV on the evaporator and a separate economizer expansion valve (ECV). A two-speed condenser fan (CF high, CL low) as well as the two-speed evaporator fans (EF, ES). The controller is Micro-Link 5.
Where things moved. The VFD is the new box between the power and the compressor, and it holds a charged DC bus after the plug is pulled (1.14). New sensors on the legend: an evaporator pressure transducer (EPT), an economizer pressure transducer (ECP) and an economizer temperature sensor (ECT).
Before you start. Whatever the fault, prove the drive's DC bus dead before you open it.