A.1Carrier ThinLINE (69NT40-541-500 to 599): reciprocating generation

Slide the drawing sideways, or open it full size.
Carrier ThinLINE, simplified
Figure A.1. Carrier ThinLINE, simplifiedOpen full size

What this generation is. Carrier's ThinLINE with the Micro-Link 3 controller: a single-speed reciprocating compressor, a thermostatic expansion valve, and a stepper-motor suction modulation valve (SMV) for capacity control. Three-phase evaporator fans on high- and low-speed contactors (EF, ES), a condenser fan contactor (CF), and electric defrost heaters on the heater contactor (HR) with a heat termination thermostat (HTT). Compressor phase sequencing goes through a controller relay (TCP on the legend).

Where things are. The legend gives each device a code and a zone on the schematic, a letter across and a number down: find the code, then the zone. The sensors are supply (STS), return (RTS), defrost temperature (DTS) and ambient (AMBS), with a supply recorder sensor (SRS), a humidity sensor (HS), and a return recorder sensor (RRS) as an option.

Changed from before. This is the base generation for Carrier in this appendix.