7.2 · (R) Yours: something you are responsible forBattery banks and chargers: float, boost, temperature, end of life

Slide the drawing sideways, or open it full size.
Charger modes and a bank's decline
Figure 7.2. Charger modes and a bank's declineOpen full size

Every battery on the ship sits on a charger, and the charger's job is to hold it at float: a voltage just high enough to keep it full without cooking it, about 13.5 V per 12 V lead-acid block, 2.25 V per cell, less when the room is hot. After a discharge the charger goes to boost, a higher voltage for a few hours, then back to float. A charger that never leaves boost boils the battery; one that never reaches float undercharges it; one whose ammeter reads zero with a battery that should be floating has quit. NiCd cells float at about 1.4 V each, against lead-acid's 2.25 V, but a 24 V bank has 19 or 20 of them, so it floats at 27 to 28 V, as high as a lead-acid bank or higher; set the charger for the bank in front of you. They tolerate abuse better; lithium banks are managed by their own electronics and the charger is part of the system.

End of life announces itself in the load test: the voltage under load falls faster and further each time, until one day it falls off a cliff. A bank that still reads the right voltage at rest is not the same as a bank that will carry its load, which is why 7.3 is a load test and not a voltmeter.

Pocket rules. Float voltage per the chemistry and the temperature. Charger ammeter at zero on float: suspect the charger. Boost that never ends boils the bank. Resting voltage proves nothing.

Yours or not. All yours.

Work it

Built for this entry. Lessons first, then the simulator for free play.

Comes up in

Other entries that send you here.

All of Part 7