3.6b · (R) Yours: something you are responsible forWhich board owns the ground?

Slide the drawing sideways, or open it full size.
The ship's electrical islands
Figure 3.6b. The ship's electrical islandsOpen full size

The most common confusion in a ground hunt is not where the ground is; it is which system it is on. A ship is several electrically separate systems, and a ground shows only on the lamps of the system it is on, because a transformer breaks the path. The 440 V bus has its lamps. Each 220 V transformer bank's secondary is its own island with its own lamps. The 110 V DC and 24 V DC supplies have their own monitors. The emergency board is part of the 440 V island while the tie is closed, and becomes its own island the moment the tie opens; a ground that vanishes when the emergency generator picks up its own board was on the main side, and one that stays was on the emergency side.

That is the first trick: read which set of lamps is showing, and you have already excluded most of the ship. The 220 V lamps lit means the fault is on the 220 V side: lighting, galley, receptacles or electronics, and the 440 V motors are innocent. The 440 V lamps lit means a motor, a heater or deck machinery, and the lighting, which is 220 V, is innocent. If both show, you have two grounds.

The second trick is for the deck light in the drawing, which could be fed from anywhere. Go to the thing, not the board. Find the fitting's own breaker: the nearest panel door lists its circuits, or the fitting has a circuit number on it, or you switch the panel's breakers one at a time until the light drops. Then read the panel's own label for its source: that panel is fed from a named breaker on a named board. Now you know which island, which board, which feeder, from the bottom up, and the key distribution plan from 0.2 confirms it. Working from the load back to the source is faster than working from the board down whenever you already know which load is suspect.

The third trick is the clamp. A leakage-rated clamp meter around all three conductors of a feeder cable reads the imbalance, which is the current leaking to the hull. On an ungrounded system that current is small, milliamps set by the capacitance of the cables, and every feeder shows a little of it. Walk the feeders on the guilty board with the clamp, and the one that reads well above its neighbors is the one; nothing gets opened.

Pocket rules. Which lamps are lit tells you which island. A transformer is a wall; grounds do not cross it. Emergency board: part of main with the tie closed, its own island with it open. From the suspect load, read the panel's source label and climb. The clamp finds the feeder without opening a breaker.

Yours or not. Yours.

Work it