Part IV · Shipboard Skills · Stage 2 · First month

Electrical Troubleshooting and Testing

Most electrical faults aboard are a lost supply, an open contact, a loose connection, or wet insulation, and a meter finds each one faster than changing parts.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

LessonMegger a Motor and Dry It OutTest the emergency fire pump motor alone at 500 V for one minute, winding to frame and winding to winding, dry it out without cooking it, and read the curve: wet, ending or faulted.LessonGround Lamps and the Ground HuntRead the three ground lamps and the insulation monitor, name the island a ground is on, half-split the board down to a wet deck light, and find a ground on a feeder that can’t be dropped with the leakage clamp.LessonThe Half-SplitFind an open among sixteen points in four readings by testing the middle of what is left, find the masthead light’s open using only the boxes you can reach, and four calls on where to read next.LessonVoltage Drop Across a ContactMeasure across each closed pole of the running LT1 contactor and find the pitted one dropping 14 V, work out the heat, see why it only shows under load, and sort six readings from a panel round.LessonLoad the MeterEighty volts on a deck lighting circuit you’ve just isolated: load the meter and watch the ghost collapse, then find the one that doesn’t; prove the meter live, dead, live; and four calls.LessonOhm’s Law: The Missing NumberA purifier heater fuse with no rating on the drawing: meter the element, work out the current and pick the fuse. Three quick ones, then volts across a lug under load.LessonSeries and Parallel: The Pump That Started by ItselfThe No. 2 hold bilge pump’s control rung: the series string, the hold-in and Hand in parallel. Then a pump running with the well dry and one that won’t run, each found with the meter.LessonSource to Load: Where Every Fault LivesEvery circuit is a source, a path and a load. On the No. 2 HT pump starter: a dead control transformer, an open coil and an open selector contact, each found by the three questions in order.LessonOne Fault at a Time, and the Second One Water MakesNo. 2 hold bilge pump won’t start: find one corroded terminal in the wet float box, fix it, test again from the load, and find the second it was hiding. Then three changes with no record, and an intermittent.LessonWhen to Stop, When to Call, How to Hand It OverRadar S’s display is dead. Prove the outside with a meter, swap in the spare, read code 17 and stop at the processor. Then the call that gets a part, and the handover the next person starts from.LessonDC Grounds: Floating or Chassis-GroundedFloating 110 V and 24 V with + and − lamps, and the EDG engine’s 24 V with its negative on the block: pull breakers, split at junction boxes, meter across the device, hunt a short.LessonGround, Short or Open: Which Do You Have?Let the symptom pick the test: ohms between conductors for a short, the megger to hull for a motor ground (multimeter for lighting), continuity end to end for an open. Then the readings that fool people.LessonReplace a Breaker, Fuse, Relay or TerminalThe five things on a breaker label, a galley breaker swapped with the feeder above locked out; three fuses matched by type, rating and speed; MAC1’s trip relay matched by coil and contacts; a hot terminal.LessonLighting: Ballasts, LED Drivers and Wet FittingsInside a fluorescent, an LED and an incandescent fitting and which part fails; four purifier room fluorescents; two dead LED floods on the bench; 120 LED drivers that look like a ground; four wet deck floods.LessonRepair a Fixture; GFCI CircuitsThe accommodation ladder light: prove it dead at the fitting (it has two feeds), find how the water got in, ohm it to hull before it goes back on. Then how a GFCI decides, and the one that won’t stay in.LessonMake Up a Cable End and GlandA deck box that filled with water through its gland: find the six faults in the old end, then make up the new one. Strip to the gland, braid into the cone, tighten and pull, ferrule, number, slack.LessonRepair a 440 V Motor Cable: The Three-Tape MethodNo. 1 LT pump’s lead cracked at the gland: prove it dead at the motor, find the core, clean it, rubber twice and vinyl over, megger it, fix the gland. Then cooked leads in FOP2’s box.LessonHow Distribution BreaksPart 3 in one sitting: eight distribution symptoms sorted to their first check, then three walked on M/V Hawsepiper: a trip with nothing changed, a trip every start, and lights that dim and stay dim.LessonHow Motors BreakPart 4 in one sitting: eight places a motor breaks, ten symptoms sorted to their first check, then three walked on Hawsepiper: hums and won’t turn, trips the breaker on start, runs, stops, runs.LessonVDR, Nav Lights and the WhistleA VDR alarm traced to a wet wing microphone, the departure test of every nav light on both lamps, a sidelight found by lamp, gasket, panel and ohms to hull, and a silent whistle.LessonExchange and PA Faults: Find the Dead BitHawsepiper’s PA and telephone exchange, the next month: a dead zone relay, a wet forecastle horn found by splitting the line, a dead line-card port, and BDB-8 tripped behind a flat battery.LessonHow Bridge Gear Breaks: Symptom to First CheckThe Part 6 round-up: eight Hawsepiper cases on the book’s tree, then a dead echo sounder, four nights of alarms that are one feed each, a weak radio, and a radar that loses heading in a seaway.LessonIsolate a Loop Fault, Swap a Detector or Call PointLoop B’s drilled cable lost as B-008 to B-011: lift the section at ISO-2 and ISO-3, meter it, half-split at the bases to the drill hole, repair and confirm; then swap a dusty head and a cracked call point.LessonGalley and Laundry: The Calls the Crew SeesRange 1’s hotplate that only does Low, found in the selector switch; Range 2’s infinite switches; walk the cycle on a dishwasher, a combi oven and a dryer; a laundry GFCI that has found a washer.LessonBoard-Level Repair: When There Is No Spare BoardFOP2’s power and output board, no spare and the exchange three weeks off: whose board it is, look then measure, the right parts and polarity, the iron and the job in order, and when to stop.LessonTroubleshoot a Battery ChargerHawsepiper’s engine room 24 V charger, CH2, opened up: door meters first, then four faults: a blown input fuse, a latched board and a cooked output fuse, a sense lead adrift, an open diode.LessonThe 4–20 mA Loop: Read It, Find the Break, Prove ItRead the milliamps before you climb the tank, read DG2’s LO pressure loop at every terminal, go card first, half-split a dead tank loop with volts across the pair, prove it with 4, 12, 20 mA.LessonThe Ungrounded System: The Ground That Waited a WeekWhy Hawsepiper’s 440 V has no link to the hull: the first ground trips nothing, moves the hull and not the phases, and waits. Then two grounds make a short.LessonAC and Three-Phase: What the Meter Is Telling YouDG2 at 59.3 Hz is an engine running slow. RMS and peak, true-RMS against average-responding on a UPS feed and a drive output, the voltmeter selector, and wye and delta windings.LessonUsing a MeterVolts AC and DC on an insulated ship, proving dead live-dead-live, continuity and ohms on dead circuits, the door ammeter and the clamp, and the megger at 500 V, on the No. 1 LT pump starter.LessonGround HuntingWhat a ground is on an insulated ship and why one trips nothing; reading the ground lamps and the insulation monitor; splitting the 220 V board once you have the go-ahead; then the megger or the multimeter, and which one for what.Simulator · free playFault BenchStarters with a fault you cannot see: operate them, read volts, ohms and amps on any terminal, find the fault, fix it and prove it. Twelve circuits (across-the-line pump, hold bilge pump on floats, wye-delta, a standby pump that starts on low pressure, a starting air compressor with its unloader and trips, and the sewage plant three ways: on floats with its blower, and two timer-run plants; the engine room crane hoist, reversing, with its limits and brake; a generator breaker's closing and tripping circuits in TEST; and an alarm system cabinet with two 4–20 mA loops and two switch inputs; and a hydrophore pump run by a PLC, where the program is your meter) and 250 faults at random.Simulator · free playMotor Starter Fault HuntTroubleshoot a three-phase motor starter with a virtual meter: find where the voltage stops and name the fault.Simulator · free playThe MeterPick the right tool, dial position and jack for 16 ship jobs, see phantom voltage and LoZ, find a burnt contact by voltage drop, and put prove-dead in order.Simulator · free playGround HuntRead the ground lamps and insulation monitor on an ungrounded ship's system, hunt a ground breaker by breaker, and tell a ground from a short or an open.

Draft: this page is drawn from the book manuscript and is still being checked.