6.9 · (R) Yours: something you are responsible forInternal comms: telephone exchange, PA, talkback, sound-powered phones, general alarm

Slide the drawing sideways, or open it full size.
Internal comms as five separate systems
Figure 6.9. Internal comms as five separate systemsOpen full size

Five systems that look alike and are not. The telephone exchange is a small switchboard, electronic now, with a battery, feeding handsets around the ship; a dead handset is usually the handset or its cable, a dead exchange is its power or battery. The PA is an amplifier with zones, and a dead zone is an amplifier channel, a zone relay or a speaker line short that has pulled the amplifier down; speaker lines are 100 V lines and a short on one takes the zone out. Talkback is a dedicated two-way system between the bridge, the control room and the steering flat, with its own amplifier. Sound-powered phones need nothing but their own handsets and a pair of wires, which is why they are the last thing working, and why they should be tested, because nobody uses them until they must. The general alarm is a contact on the bridge and in the control room that rings every bell and sounder, with its own supply from the emergency board and a battery; it is tested weekly and it is not a system to find faulty on the day.

Pocket rules. Dead handset: handset. Dead zone: speaker line short. Sound-powered phones: test them, nobody else does. General alarm: weekly, logged.

Electrical or mechanical. All electrical. Exchange programming: the manual or the vendor.