8.5One fault at a time, and the second one water makes

Slide the drawing sideways, or open it full size.
Two faults, found one at a time
Figure 8.5. Two faults, found one at a timeOpen full size

The method finds one fault. Fix it, then test again from the load end, and if the load is still dead, start over, because there was a second one. Water likes to make two: a wet junction box corrodes two terminals, a flooded fitting opens a wire and grounds another. An intermittent that comes and goes is one fault pretending to be several; find the one and the others vanish. The discipline is to resist fixing three things at once, because then you do not know which one was the fault, and the next person inherits a circuit with three changes and no record.

Pocket rule. Fix one, re-test from the load. Water makes two.