Water. Deck fittings, galley, laundry, reefer receptacles, davit connections, call points. Grounds and GFCI trips.
Heat. UPS and charger fans, galley elements, power supplies. Fans first.
Vibration. Boards and connectors, especially near machinery. Reseat before you replace.
Neglect. Batteries that were never load-tested, ICCP never logged, lifeboat chargers never checked, sound-powered phones never tried. These fail on the day of the drill or the survey, and the fix is a routine (Part 9), not a repair.
A UPS alarm. Battery self-test, then the fans, then the loads on it.
A fire panel fault. Lost addresses bracket it; dirty heads and wet devices before cables.
The galley GFCI trips. One appliance at a time until it stays in.
Something you have never seen. Its manual is on the ship somewhere, and its controller has a fault code. Read both before you open it.