7.11 · (R) Yours: something you are responsible forICCP, shaft grounding and marine growth prevention

Slide the drawing sideways, or open it full size.
ICCP, shaft grounding and MGPS (figures from a real ship)
Figure 7.11. ICCP, shaft grounding and MGPS (figures from a real ship)Open full size

The hull is protected from corrosion by impressed current: anodes through the shell plating push current into the water, reference cells measure the hull's potential against seawater, and a control unit adjusts the anode current to hold that potential in the protected band. The shaft would be isolated from the hull by its oil film, so a brush and slip ring tie it back, and a millivolt meter across the brush shows it is working; at sea it should read under about 50 millivolts, and more than that means a worn or badly seated brush or a dirty ring, and a shaft that is not grounded eats its bearings by spark erosion. The marine growth prevention system puts copper and aluminum anodes in the sea chests and dissolves them slowly to keep the coolers clean.

All three are log readings and small maintenance: the ICCP's current and reference voltages weekly, the shaft brush's millivolts and wear, the MGPS anode currents. An ICCP that has drifted to maximum current with the reference out of band usually has a failed anode or a reference cell fouled; one at zero is a control unit or a blown fuse.

Pocket rules. ICCP: reference in band, current reasonable, weekly. Shaft brush: millivolts low, brush worn means bearings next. MGPS: anode current, and change them when the current drops.

Electrical or mechanical. All electrical; anodes and reference cells through the hull are dry-dock jobs.