4.16 · (F) A job you do with your handsCrane and winch control faults: limits, brakes, contactors

Slide the drawing sideways, or open it full size.
Limit, brake, contactor: three checks in order
Figure 4.16. Limit, brake, contactor: three checks in orderOpen full size

A motion will not run. First the limits: find the limit switches for that motion on the drawing and the diagnostic page, and check which one is operated. A limit that is correctly operated means the motion has reached its end and the crane is right; one that is operated when it should not be is corroded, knocked, or its cam has moved. Second the brake: command the motion and measure across the brake coil; coil voltage present and no release is a seized brake or a dead coil; no voltage is a control problem upstream. Third the contactor or drive: does the command arrive at the coil or the run terminal, and does it close or run. Then the motor itself, last, by clamp and megger.

Brakes that drag heat the motor and trip the drive on overcurrent; brakes that do not hold let a load creep, which is a stop-everything fault. Both are adjustment or coil problems and both have a vendor procedure.

Pocket rules. Limits, brake, contactor, motor, in that order. Measure across the brake coil. A dragging brake looks like a motor fault. Creep is a stop-work fault.

Work it

Built for this entry. Lessons first, then the simulator for free play.

LessonWindlass, Mooring Winches and Hatch CoversMW3, the port aft mooring winch: what is yours on deck, two speeds and two overloads, a motor that hums against its brake, rain in the control station, and No. 2 hatch cover held by its own limit.LessonDeck Cranes: Hoist, Slew, Luff, Brakes, LimitsDeck crane CR1: whose parts are whose, a crane that cuts out slewed to port, the hoist chain, limits first from the diagnostic page, three valve-coil faults, and six calls.Simulator · free playFault BenchStarters with a fault you cannot see: operate them, read volts, ohms and amps on any terminal, find the fault, fix it and prove it. Twelve circuits (across-the-line pump, hold bilge pump on floats, wye-delta, a standby pump that starts on low pressure, a starting air compressor with its unloader and trips, and the sewage plant three ways: on floats with its blower, and two timer-run plants; the engine room crane hoist, reversing, with its limits and brake; a generator breaker's closing and tripping circuits in TEST; and an alarm system cabinet with two 4–20 mA loops and two switch inputs; and a hydrophore pump run by a PLC, where the program is your meter) and 250 faults at random.Simulator · free playCrane ControlFault-find an all-electric crane hoist's control: emergency stops, limit switches, the overload limiter, hoist contactors and the spring-applied brake, with a meter on the ladder diagram.Simulator · free playElectro-Hydraulic Deck CraneDeck crane CR1, electro-hydraulic, 25 t: a wye-delta pump motor, the hydraulic power unit, a PLC with its lights and diagnostic page, valve coils, limits, the SWL limiter and the slip rings. Take a fault, find it with the meter, fix it and prove it.

Comes up in

Other entries that send you here.

All of Part 4