4.12 · (R) Yours: something you are responsible forSteering gear motors and control

Slide the drawing sideways, or open it full size.
Steering gear power and control
Figure 4.12. Steering gear power and controlOpen full size

Steering is the one motor system the regulations treat differently. Two pumps, each with its own motor, each on its own circuit from the main board; one of the two may come through the emergency board, and usually does. The motors are protected against short circuit but not by an ordinary overload: steering must not trip on overload, so there is an alarm instead, and a phase-failure alarm, and any overcurrent protection that is fitted is set at no less than twice full-load current, so a hard-over rudder never trips it. Starters live in the steering flat with remote start and stop and run indication on the bridge, and a loss of power on either pump alarms on the bridge.

The control side is the autopilot's and the helm's commands reaching the pump's directional valves, solenoid or proportional, with feedback from the rudder angle transmitter. Follow-up and non-follow-up modes are the two ways the bridge can drive it; the emergency steering from the flat bypasses the bridge entirely and is tested on the schedule the SMS gives.

Pocket rules. No overload trip, an alarm instead. Two pumps, two sources. Phase failure alarm on each. Know the emergency steering test and do it with the bridge.

Electrical or mechanical. Motors, starters, alarms, remote controls, solenoids, rudder angle transmitter: electrical. Pumps, rams and the hydraulics: mechanical. The test: both, with the bridge.

Work it

Built for this entry. Lessons first, then the simulator for free play.

All of Part 4