3.10 · (F) A job you do with your handsRepair a fixture; GFCI circuits

Slide the drawing sideways, or open it full size.
How a GFCI decides to trip
Figure 3.10. How a GFCI decides to tripOpen full size

Fittings. Isolate at the breaker and prove it dead at the fitting; lighting circuits get fed from unexpected places. Replace the ballast or driver with a matched unit, replace the gasket, clear the drain hole, re-make the gland, and before you re-energize, put the multimeter on ohms from each conductor to hull: a lighting circuit either has a ground or it doesn't. If the fitting has been wet, the terminal block inside is suspect even if it looks fine.

GFCI. A ground-fault circuit interrupter watches the current going out and coming back through one small transformer; if they differ by a few milliamps, some current is finding another way home, probably through a person, and it trips. It compares the two conductors with each other, not with ground, so it needs no grounded neutral to work. On an ungrounded system a single leak to hull has no solid way home, but the cables' own capacitance to hull is a way home, and on a ship-sized system that is enough to trip it and enough to hurt: one line to hull is never safe. It works hardest when there is already a ground somewhere else on that system, which is the day a person completes the circuit. It cannot see a person across both conductors, because that current goes out on one and comes back on the other. They are fitted on receptacles in galleys, laundries, bathrooms and on deck. One that trips repeatedly with nothing plugged in has a wet downstream receptacle or a damaged cable; one that will not trip on its test button is dead and gets replaced.

Pocket rules. Prove dead at the fitting, not just at the breaker. Ohm it to hull before you re-energize anything that was wet. Test every GFCI monthly with its button; replace any that fail.

Work it

Built for this entry. Lessons first, then the simulator for free play.

All of Part 3