Part III · The Engines · Stage 2 · First month

Starting, Reversing, Governors, and Control

This is what sets the loop going and holds its speed: starting air turns the engine until it fires, the reversing gear picks the direction, the governor sets the fuel at the inject step, and the control system decides who gives the orders. Its faults show at the worst moment — a start that doesn't come, a slow astern — so most of the work is proving it before you need it.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Starting air at the engine25–30 bar; low alarm commonly 15–20 bar
Starts from full receivers (class rules)12 reversible, 6 non-reversible; compressors refill them from empty in about an hour
Air cut-off (firing speed)Roughly 15–25 % of MCR rpm
Remote start attemptsCommonly three, then START FAILED
Full ahead to running astern, ship at speed1–2 min or more
Speed droop, generators in parallel3–5 %, equal on every set
Generator, full load thrown offMomentary rise under 10 %
Overspeed trip, generator / main engine110–115 % of rated / about 110 % of MCR rpm
ME hydraulic oil; RT-flex servo / control oil200–300 bar; 80–200 / about 200 bar

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
START BLOCKEDInterlock lampsTurning gear; LO pressure; control position; reversing gear short; shutdown not resetClear the cause — never jumper it
Won't turn on air, nothing blockedManifold pressureMain start or block valve shut; control air off; start solenoidValves; control air; solenoid
Turns on air, won't fireIndex during the startShutdown not reset; load limit at 0; start limiter low; fuel coldReset; load limit up; fuel
START FAILED after it firedRpm displaySpeed pickup dead or gap wrongPickup; bottom of the standby order
Hunting, or slow to recoverGovernor oil; racksOil low or aerated; sticky racks; fuel; needle mis-setOil, racks, fuel, then compensation
Set won't take its shareDroop; mode; raise/lowerDroop unequal; one set isochronous; raise motor dead; load limitSee Generators and AVRs
Overspeed on load rejectionRacks free; trip settingGovernor sluggish; linkage sticking at fuel; trip set lowRacks, governor, trip test
Keeps turning after STOPEach rackLinkage loose — one pump stuck at fuelEmergency fuel shut-off
Rpm short, index on the limiterScavenge pressureAir side fouled; running heavy; limiter signal lowAir side; tell the bridge
Slow reversal, air fallingCompressors; gear timeCompressors behind; servomotor slow; leaksAll compressors; bridge in starts
Wrong-way alarmGear end positionServomotor short of travel; position switchStop; check the gear