M/V Hawsepiper · first draft of this billet

Electrician / Reefer Tech

The unlicensed electrical billets. Short lessons, and a bench where you learn each reefer unit by its drawing, its controller and its faults.

Reefer Tech: the Reefer Bench

Pick a unit. Each one has the unit itself, its electrical drawing redrawn in our own style, a working controller, a meter, guided lessons and a set of faults to find.

Electrician: short lessons

Six steps each, about seven minutes. Each ends with links to the deeper ETO lessons and the Fault Bench.

Lesson 1Using a MeterVolts AC and DC on an insulated ship, proving dead live-dead-live, continuity and ohms on dead circuits, the door ammeter and the clamp, and the megger at 500 V, on the No. 1 LT pump starter.Lesson 2Vocabulary: The Words on Day OneAbout forty electrical words you meet on your first day, learned by tapping the parts of a starter, the ship's power, a set of cards and a ladder rung, then a quick match.Lesson 3Reading a Wiring Diagram and a LadderThe No. 1 LT pump starter drawn as a ladder and as a wiring diagram. Find each part on both, trace a rung, follow wire and terminal numbers, and go from the ladder to the right two screws.Lesson 4Motor ControllersWhat an across-the-line starter does, start and stop with the seal-in, setting and resetting the overload, reversing with two interlocked contactors on the engine room crane, and the top faults.Lesson 5Ground HuntingWhat a ground is on an insulated ship and why one trips nothing; reading the ground lamps and the insulation monitor; splitting the 220 V board once you have the go-ahead; then the megger or the multimeter, and which one for what.Lesson 6The GalleyRanges and their hotplate selectors, the oven and combi oven, the fryer and its high limit, the dishwasher, and the boiling pan (a steam-jacketed kettle): what each does, the core parts, and the faults you will be called for.Lesson 7The LaundryWashers (door lock, heater, drain pump, inverter motor), the dryer (heater, airflow switch, high limit, lint) and the laundry GFCI: what each part does, and the calls you get on a Sunday.Lesson 8Replacing Motor BearingsThe No. 1 LT pump motor’s drive-end bearing has gone. Mark it before it comes off, pull the old bearings with a puller, match 6311-C3 and 6211-C3, heat the new ones on to about 110 °C, run it uncoupled, then line it up.Lesson 9The Troubleshooting Method on One PageThe ETO book's Part 8 moves in one short lesson. Before you open the box, source to load, the half-split, voltage drop, load and prove the meter, one fault at a time, when to stop and call, and one practice fault on the No. 1 LT pump.