Valves decide where every fluid goes, how much gets there, and which way it may flow. Most lineup mistakes are a valve in the wrong position or a valve that isn't holding.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Handwheel | Clockwise to close, viewed from the wheel |
| Rising-stem gate or globe | Stem out = open; stem in = closed |
| Ball, butterfly, plug | Handle in line with the pipe = open; across = closed |
| Gate or globe "fully open" | To the stop, then back ¼–½ turn |
| Valve gland | Dry. Weep — take it up; drip — repack |
| Relief valve | Seated, quiet, outlet dry |
| Reducing valve | Downstream steady at set; no creep when flow stops |
| Stopped standby pump | Doesn't turn backwards |
| Remote valve | Indicator matches mimic and lineup |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Pressure stays on an isolated section | Section gauge; each boundary valve | A valve leaking by | Add a third valve; find the passing one |
| Remote valve shows open, no flow | Pump suction gauge; the valve | Actuator stuck; coupling sheared | Cycle it; prove with manual override |
| Handwheel turns, nothing changes | Is the stem rising? | Wedge off stem; threads stripped; disc pin sheared | Isolate elsewhere; open up |
| Won't close the last turn | Body bottom | Scale, rags, growth on the seat | Open a few turns, re-close; open bonnet |
| Valve won't move | When it was last worked | Seized stem; thermal binding; corroded skin valve | Work gently; don't force a skin valve |
| Gland weeping or dripping | Gland nuts | Packing worn or loose | Take up a flat; repack if no response |
| Standby pump turning backwards | Its discharge check | Check stuck open or seat failed | Shut its discharge; overhaul the check |
| Pump won't pull from one tank or well | Suction bonnets | Rags; stop-check disc stuck; valve shut | Open bonnets and clear |
| Relief weeping or lifting | Pressure vs set | Over-pressure; dirt on seat; setting drifted | Find cause; lift to clear; bench reset |
| Reducer outlet rising to supply | Flow at the time | Seat leaking at no flow | Clean or rebuild seat |
| Temperature hunting on a three-way | Auto or manual; position | Positioner; tired wax element | Hand-control; repair |
| Fire main won't hold pressure | Overboard and hydrant valves | Fire pump overboard left cracked after stripping; hydrant leaking | Close tight; use a different hydrant |
Draft: this page is drawn from the book manuscript and is still being checked.