Part I · The Plants

Steering Gear

The steering gear turns a bridge order into rudder angle: a control signal selects direction, a hydraulic power unit supplies the force, an actuator on the rudder stock moves the rudder, and a feedback unit tells the control when to stop. Everything is doubled — two control systems, two power units on two supplies, and a local position in the steering flat.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
System pressure, rudder moving60–150 bar
System pressure, rudder at rest, pump runningnear zero to 10 bar (pump at null)
Relief valve settingnot above design pressure (≥ 1.25 × max working pressure)
Oil temperature30–55 °C; alarm 65–70 °C
Hard-over 35° to 30°, main gear≤ 28 s at max service speed
15° to 15°, auxiliary steering gear≤ 60 s at half max speed or 7 kn, whichever is greater
Bridge indicator vs rudderwithin 1°
Emergency supply restoration (stock > 230 mm)automatic within 45 s

The tour

The plant, stop by stop, as the book walks it.

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Hunting in FU, steady in NFUFeedback linkage pinsLoose linkage; dirty potentiometer; amplifier gainPin the linkage; electrical
Slow both directionsPumps running; pressure during movement; oil tempOne pump only; relief passing; internal leakage; worn pump; airStart 2nd pump; compare pressures; bleed
Slow one direction onlyPressure each side; swap pumpsSolenoid or stroke one side; one lock valve; one ram sealSwap pumps to localize
Rudder stops, pressure at relief, amps highIsolation valves; lock valves; stopsIsolation valve shut; lock valve stuck; on the stop, limit switch failed; jamStop the pump; open; free
Pump running, no pressure, rudder won't move on that unitCoupling, through the guardCoupling slipped off; insert gone; pump shaft teeth wornOther pump; refit coupling; check teeth
Hydraulic lock alarm on one pump, clears itselfTime that pump alonePilot valves sticking; directional solenoid; lock valveWalk to the gear; renew pilot valves
Rudder drifts off order in a seawayBypass valve; lock valvesBypass passing; lock valve leak; internal sealSeat the valves; test holding
Bridge indicator disagrees with tiller pointerTransmitter linkageLinkage bent or slipped; zero driftedRe-zero to the pointer
Oil level fallingRam glands; bilge; storage tank levelGland; vane seal to rudder trunk; cooler; transfer valve passingFind it; top up; sample
Pump overload alarmAmps; oil temperatureBinding; relief stuck shut; cold oil; phase failureOther pump; find the cause

Scenarios

Work out what you’d do, then open it.

one pump alarms under way

Coastal passage, both pumps running for the pilotage. No. 1 overload alarm, then No. 1 stops. What have you lost, and what do you tell the bridge?

Steering is not lost — rate is. On one unit the gear may not make 35° to 30° in 28 s, so tell the bridge now, then the engineer in charge. Then the cause: amps on each phase, oil temperature, and whether No. 2 now draws more than normal, which points at binding or a relief valve rather than the motor. No. 1 is not reset until you know why it stopped.

slow to starboard only

The pre-departure test times 24 s to port and 38 s to starboard. Both pumps give the same result. Where is the fault?

Both pumps the same puts it downstream: the valve block or the actuator. One direction only means the starboard half of the circuit — that side's solenoid or stroke, the lock valve that lets oil out of the opposite cylinder, or a seal that leaks only under starboard load. Low peak pressure with slow travel is leakage; high peak is restriction. After oil work, bleed first.

the alarm that clears itself

At night the hydraulic lock alarm on No. 1 unit comes in and clears before you reach the control room. It has done this for months; the log calls it nuisance. Do you go aft?

Yes, every time. The alarm means the rudder lagged the order — something in No. 1's valve block is sticking. Time each unit alone. Intermittent hydraulic lock on one unit is failing pilot valves: a cheap change, compared with a unit that stops answering in a channel.

bridge loses steering control

0200, the bridge calls: the wheel does nothing, the rudder is stuck at 5° port. What happens, in what order, and what else is affected?

Bridge: select the other control system; try NFU on each. If nothing moves, call the engineer in charge, put the gear in local, and steer to the repeater on helm orders by phone — the ship is under control again in a minute or two. The engine stays on standby and is stopped or put astern only if ordered; speed comes down, and the autopilot is out until bridge control is back.

Then investigate: control system power at the steering flat first, then the linkages. A fastener backed off a feedback linkage is a known cause of lost steering, and the reason fasteners are checked before every departure.

Dependencies

Needs
  • Electrical — two feeders from the main switchboard, one via the emergency switchboard; control systems fed from the power circuits
  • Hydraulic oil — correct grade, clean and dry, storage tank full
  • Gyro — autopilot and the steering flat repeater
Feeds
  • Controllability — the ship's ability to hold a course and turn
  • Autopilot and track control
  • Unattended machinery space operation — lost with any steering gear alarm until it is cleared

Draft: this page is drawn from the book manuscript and is still being checked.