Sewage Treatment Plants

A sewage treatment plant turns what the toilets send it into water you may pump overboard — by growing bacteria that eat the load, filtering it through a membrane, or making chlorine from seawater. Sewage and Gray Water walks the system from toilet to overboard.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Aeration chamberBrown, mixed, earthy smell; no gray, black, or rotten egg
Dissolved oxygen, aeration chamber1–3 mg/L
Blower discharge0.2–0.4 bar, steady
Settling jar, 30 minDistinct sludge layer, clear water above
Effluent pH6–8.5
Residual chlorinePer the certificate; current IMO-approved plants under 0.5 mg/L
Discharge pump against a shut overboard valveAbout 1.4–1.6 bar on one plant; your baseline is the number
New seed to establish1–3 weeks, fed lightly
MBR trans-membrane pressureLow tenths of a bar; the trend is the reading
Electrolytic cellCurrent at set; volts creeping up for the same current is scale
Liquid-ring pump seal waterFlowing at the maker's rate, cool to the hand

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Aeration black, sulfur smell, blower runningBlower pressure; bubbling patternDiffusers plugged; air valve shut; air line leakingClear the diffusers; fix the air; re-seed
Thick white foamRecent cleaning day; age of seedDetergent slug; young sludgeHose foam and walls down; stop the detergent
Effluent cloudy, solids over the weirSludge return; sludge depth in settlingAirlift plugged; settling chamber full; transfer too fastFlush return tubes; waste sludge; transfer slower
Blower hot, pressure lowInlet filterFilter blocked; air line leak; blower wornClean filter; find the leak; overhaul
Residual zero, tablets presentTube for bridging; flow past itTablets swollen and jammed; flow bypassing; DPD bleachedClear to 1–2 tablets; prove flow; dilute and retest
MBR flow falling, TMP risingScour air; mixed liquorFouling; scour lost; dead biologyBackwash; clean in place; fix air; re-seed
Electrolytic volts high, chlorine fallingFlushing water sourceScale; fresh water with no chlorideAcid wash; restore seawater or dose brine
Macerator trips on overloadCutter housingWipes or rags; dull cutter; wrong rotation after motor workLock out, open, clear by hand; check rotation and gap
MSD circulation or transfer pump overload alarmAmps against baselineRags in the impeller; wear; bearingFind the cause; raising the set point is a stopgap
Liquid-ring pump hot, vacuum poorSeal water flow and temperatureSeal water lost, strainer blocked, or hot; worn impellerRestore cool seal water; overhaul
Vacuum pumps run continuously; toilet branches clearGray water branches, one at a timeInterface valve stuck open — paper, diaphragm, controllerFind the hissing cold valve; rebuild
Sinks on one deck back up, toilets fineThe interface unit under themController, signal tube, or diaphragm failed; branch isolatedTest the controller; rebuild the valve
Discharge pump runs, level holdsFloats; pressure; check valveAir-bound below the floats; float stuck on the suction; check valve hung upFlush the inlet; Hand until pressure reads zero, then Auto; shorten floats