The sewage plant collects what comes out of every toilet into a tank under vacuum, then treats it, pumps it out where the law allows, or holds it until it can. Gray water from sinks, showers, laundry, and galley goes the same way or straight overboard.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Vacuum in the piping | −0.35 to −0.55 bar |
| Vacuum pump cut-in / cut-out | about −0.35 / −0.55 bar |
| Flush water per toilet | 1–1.5 L |
| Vacuum pump starts at sea | a few per hour; more at mealtimes |
| Collection tank | pump down at high-normal; stop well above the low alarm |
| Aeration blower pressure | 0.2–0.4 bar |
| Chlorine tablets in the feed tube | 1–2 |
| Chlorine residual at discharge | per the plant's certificate; under 0.5 mg/L on current IMO-approved plants |
| Black water per person per day, vacuum system | about 15–25 L; gray water separate |
The plant, stop by stop, as the book walks it.
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Vacuum pump long-run alarm, vacuum low | Port and starboard branches in turn | Toilet sucking air; pipe leak | Search rooms; reseal or rebuild |
| Pump runs long or short-cycles, no leak | Flapper valve | Paper holding it open; check valves hung up | Swap flapper; flush valves |
| Hiss at one toilet, bowl dry | Flush valve | Boot not seating; debris | Bottle trick; replace boot |
| Toilets on one deck won't flush | Vacuum to that branch | Branch isolated or blocked | Open; clear the branch |
| No or low water in the bowl | Water valve | Timing or diaphragms; vacuum line off | Rebuild the water valve |
| Toilet clogged | Which toilet, what day | Wipes, pads, paper | Pull and clear by hand — never plunge |
| Low-level and vacuum alarms, tank near empty | Overboard valve; transfer valves | Siphoned; transfer valves passing | Shut valve; add water; transfer by hand |
| Vacuum alarms in a hot port | Switch settings | Set points drifted with heat | Lower in port; restore at sea |
| Breaker trips restarting vacuum pumps | Pumps started together | Inrush | Pumps off; restart one at a time |
| MSD discharge pump running all night | Pressure; floats | Air-bound; float on suction | Flush inlet; Hand to zero, then Auto |
| Foam on the plant or tank | Recent cleaning | Detergent | Hose down walls; bacteria weekly |
| Aeration chamber gray, rotten smell | What went down the drains | Bleach; aeration stopped | Stop the chemical; re-seed |
| Residual zero, or UV alarm | Tablet tube; UV lamp | Tablets empty or jammed; lamp failed | 1–2 tablets; replace lamp |
| Smell in the accommodation | Dry traps; vents | Unused cabins; blocked vent | Fill traps; clear vent |
Work out what you’d do, then open it.
The vacuum pump long-run alarm comes in. You reset it; it's back an hour later. Is this a morning job?
No. Days against an air leak wreck the pump — impeller, seal, then motor bearing — and the standby follows if the leak is still there. Close the port and starboard branches in turn, then search that side, bottom deck up. Cross-connect both pumps if the hiss is hard to hear. Reseal with the bottle trick; rebuild if that fails.
At sea, no pumping in progress, the collection tank low-level alarm comes in, then vacuum alarms. Within the hour toilets stop flushing. What was left open?
The overboard valve, left open after the last pump-down, siphoned the tank dry; no liquid, no vacuum. Shut it by its hand wheel and add water until the alarm clears. If it was shut, suspect the automatic transfer valves draining the tank into the MSD; run the transfer by hand on one inlet valve until they're fixed.
The MSD high-level alarm is in. The discharge pump is running at near-zero pressure. The plant was fed by hand that afternoon. What's happening?
Air-bound below its floats, it will run dry all night. Stop it, free the low-level float from the suction, flush the inlet, and restart. If it recurs, make the lasting fixes in Stop 4.
The ship anchors for an open-ended wait in a no-discharge zone, and twenty riders join. What runs out, in what order?
The collection tank is the clock, and the riders shorten it. At high level the ejector and vacuum start to fail and toilets stop flushing ship-wide; a held gray water tank fills on the same timescale. Work out the days of capacity now, divert to the tank of last resort before you need it, write down the lineup, and check for blanks. Once at sea, pump the spare tank out on a day-work day and rinse the collection tank.