A purifier spins oil in a disc-stack bowl so water and solids are thrown outward and clean oil leaves from the center. Every fuel and lube oil system on the ship depends on one, and most of what goes wrong is a lost water seal, a bowl that won't open or close, or a bowl that won't come up to speed.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Inlet temperature, HFO / VLSFO | 85–98 °C per bunker report, held within 2 °C |
| Inlet temperature, LO | 85–95 °C |
| Inlet temperature, MDO / MGO | Unheated to 40–50 °C |
| Clean oil back pressure | 1.5–2.5 bar |
| Throughput, HFO | 20–50 % of nameplate |
| Throughput, LO | 20–30 % of nameplate; sump turned over 3–5 times a day |
| Desludge interval, HFO | 30 min–2 h |
| Desludge interval, LO / MDO | 1–4 h, or longer on clean distillate |
| Operating water pressure | 2–6 bar |
| Run-up time to full speed | 3–10 min |
| Motor amps | High through run-up, then falling to a steady running value |
| Gravity-disc limit, fuel density at 15 °C | about 991 kg/m³ |
| Gravity-disc-less (Alcap-type) limit | about 1010 kg/m³ |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Oil at the water outlet, line warm between shots | Shot timer; local temperature | Seal not made; disc too large; inlet cold (denser oil), or near 100 °C so the seal water flashes; feed or back pressure too high | Stop feed; remake the seal; check temperature, then disc against density |
| Oil at sludge outlet between shots, bowl leakage alarm | Operating water pressure; hours since overhaul | Main seal ring or sliding-bottom seals worn; closing water low | Due for service — full seal kit |
| Bowl won't discharge | Operating water pressure and strainer | Strainer blocked; opening solenoid; carboned bottom-bowl passages; nozzle blocked | Manual shot; clean strainer; strip the bowl |
| Bowl won't close or seal, breaks over on every start | Closing water flow; work recently done | Scored sliding bottom or seal ring; nozzles blocked by grease; wrong disc; closing water low | See Fix — work through in order |
| Bowl slow to speed, or stuck at a few hundred rpm | Coupling locked? Amps | Friction pads worn or oily; belt slipping; bowl height wrong after rebuild | Inspect pads and belt; check bowl height |
| Low bowl speed trip on HFO only | Inlet pressure vs an independent gauge | Inlet sensor reading high, flooding the bowl at start; pads or belt marginal | Prove the sensor first; then pads and belt |
| High-pressure trip at start | Return and outlet valves | Return to tank shut; outlet valve shut | Line up; restart |
| Water in clean oil, water alarms frequent | Inlet temperature; tank kicks | Disc too small; inlet cold; wet tank; feed too high | Correct temperature; drain the tank; smaller feed |
| Water transducer or communication alarms, intermittent | Terminal box; when it happens — at shots, in cold weather | Water block worn; flushing water valve; fuel in the junction box; loose connection or failing board | Open the box before condemning the sensor; never fade the alarm out |
| Sludge port plugged | Tank in use; fuel temperature | Wax from a cold tank; bad fuel batch | Heat the tank; strip and clean the bowl |
| Sludge tank filling fast, both purifiers packing | Bunker in use | Bad batch; incompatible blend; wet fuel | Clean bowls; reduce feed; sample the fuel; change tanks if you can |
| Vibration or metal-on-metal noise | Bowl assembly marks; crankcase oil | Bowl out of balance or misassembled; spindle springs or bearings failing | Stop; inspect; overhaul |
| Temperature swinging around setpoint | Local thermometer; steam valve | Poor steam regulator; fouled heater; trap failed; manual crank broken | Hand-control; clean heater; repair trap or valve |