Part II · The Equipment · Family 2 · Clean It · Stage 1 · Before your first watch

Purifiers and Centrifuges

A purifier spins oil in a disc-stack bowl so water and solids are thrown outward and clean oil leaves from the center. Every fuel and lube oil system on the ship depends on one, and most of what goes wrong is a lost water seal, a bowl that won't open or close, or a bowl that won't come up to speed.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Inlet temperature, HFO / VLSFO85–98 °C per bunker report, held within 2 °C
Inlet temperature, LO85–95 °C
Inlet temperature, MDO / MGOUnheated to 40–50 °C
Clean oil back pressure1.5–2.5 bar
Throughput, HFO20–50 % of nameplate
Throughput, LO20–30 % of nameplate; sump turned over 3–5 times a day
Desludge interval, HFO30 min–2 h
Desludge interval, LO / MDO1–4 h, or longer on clean distillate
Operating water pressure2–6 bar
Run-up time to full speed3–10 min
Motor ampsHigh through run-up, then falling to a steady running value
Gravity-disc limit, fuel density at 15 °Cabout 991 kg/m³
Gravity-disc-less (Alcap-type) limitabout 1010 kg/m³

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Oil at the water outlet, line warm between shotsShot timer; local temperatureSeal not made; disc too large; inlet cold (denser oil), or near 100 °C so the seal water flashes; feed or back pressure too highStop feed; remake the seal; check temperature, then disc against density
Oil at sludge outlet between shots, bowl leakage alarmOperating water pressure; hours since overhaulMain seal ring or sliding-bottom seals worn; closing water lowDue for service — full seal kit
Bowl won't dischargeOperating water pressure and strainerStrainer blocked; opening solenoid; carboned bottom-bowl passages; nozzle blockedManual shot; clean strainer; strip the bowl
Bowl won't close or seal, breaks over on every startClosing water flow; work recently doneScored sliding bottom or seal ring; nozzles blocked by grease; wrong disc; closing water lowSee Fix — work through in order
Bowl slow to speed, or stuck at a few hundred rpmCoupling locked? AmpsFriction pads worn or oily; belt slipping; bowl height wrong after rebuildInspect pads and belt; check bowl height
Low bowl speed trip on HFO onlyInlet pressure vs an independent gaugeInlet sensor reading high, flooding the bowl at start; pads or belt marginalProve the sensor first; then pads and belt
High-pressure trip at startReturn and outlet valvesReturn to tank shut; outlet valve shutLine up; restart
Water in clean oil, water alarms frequentInlet temperature; tank kicksDisc too small; inlet cold; wet tank; feed too highCorrect temperature; drain the tank; smaller feed
Water transducer or communication alarms, intermittentTerminal box; when it happens — at shots, in cold weatherWater block worn; flushing water valve; fuel in the junction box; loose connection or failing boardOpen the box before condemning the sensor; never fade the alarm out
Sludge port pluggedTank in use; fuel temperatureWax from a cold tank; bad fuel batchHeat the tank; strip and clean the bowl
Sludge tank filling fast, both purifiers packingBunker in useBad batch; incompatible blend; wet fuelClean bowls; reduce feed; sample the fuel; change tanks if you can
Vibration or metal-on-metal noiseBowl assembly marks; crankcase oilBowl out of balance or misassembled; spindle springs or bearings failingStop; inspect; overhaul
Temperature swinging around setpointLocal thermometer; steam valvePoor steam regulator; fouled heater; trap failed; manual crank brokenHand-control; clean heater; repair trap or valve