Every plant moves its fluid with pumps, and most pump problems are the same problem in a different room. The pair of gauges on either side of the pump — suction and discharge — tells you nearly everything.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Centrifugal suction, flooded | 0.1–0.5 bar positive |
| Centrifugal suction, lift from a tank below | up to −0.5 bar (vacuum) |
| Gland packing drip | 20–60 drops per minute, steady |
| Mechanical seal leakage | none visible |
| Bearing housing temperature | ambient + 20–40 °C; too hot to hold a hand on means check it with the IR gun |
| Motor amps vs nameplate | 60–95 % at normal flow |
| Suction strainer ΔP — clean / change over | < 0.1 / 0.3 bar |
| PD relief valve setting | 10–15 % above working pressure |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Discharge pressure low, suction normal, amps low | Direction of rotation; discharge valve | Reverse rotation after motor work; worn impeller or wear rings; discharge valve throttled | Correct rotation; open valve; overhaul |
| Discharge pressure swinging, gravel noise | Suction gauge | Cavitation — strainer blocked, suction valve partly shut, tank low, liquid hot or viscous | Clear suction; slow down; cool or heat the liquid |
| Suction vacuum higher than usual | Strainer ΔP; tank level | Strainer loading; suction line partly blocked; tank running low | Change over strainer; sound the tank |
| Pump runs, no flow, amps low | Suction gauge; vent cock | Lost prime — air in casing, foot valve passing, suction leak | Vent and prime; find the air leak |
| Pump runs, no flow, amps high | Discharge valve; coupling | Discharge shut; impeller jammed; PD pump dead-headed | Open discharge; stop and inspect |
| Gland hot, drip stopped | Packing gland nuts | Over-tightened packing; dry packing | Back off nuts; repack if scored |
| Gland streaming | Packing | Packing worn, shaft sleeve scored | Repack; sleeve if scored |
| Mechanical seal dripping | Seal faces; product temperature | Faces worn or cracked; run dry once; wrong seal for liquid | Replace seal cartridge |
| Bearing hot | Grease level; coupling alignment | Over- or under-greased; misalignment; bearing failing | Correct grease; realign; replace bearing |
| Vibration new or rising | Coupling; mounting bolts; impeller balance | Misalignment; loose bolts; impeller damage or fouling | Realign; tighten; inspect impeller |
| Motor trips on overload | Amps; rotation; liquid density | Wrong rotation; blocked impeller; heavier liquid than design; motor fault | Correct cause before reset |
| PD pump pressure falls as oil warms | Oil viscosity | Normal — thin oil slips past worn clearances; pump worn | Trend it; overhaul when it can't make pressure hot |
| PD relief valve lifting continuously | Discharge path | Downstream valve shut or filter blocked; relief set too low | Open the path; reset relief |
| Standby pump won't take load in parallel | Discharge check valve; impeller condition | Check valve stuck; weaker pump held closed by the stronger one | Free the check valve; overhaul the weak pump |
Draft: this page is drawn from the book manuscript and is still being checked.