Part II · The Equipment · Family 1 · Move It · Stage 1 · Before your first watch

Pumps

Every plant moves its fluid with pumps, and most pump problems are the same problem in a different room. The pair of gauges on either side of the pump — suction and discharge — tells you nearly everything.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Centrifugal suction, flooded0.1–0.5 bar positive
Centrifugal suction, lift from a tank belowup to −0.5 bar (vacuum)
Gland packing drip20–60 drops per minute, steady
Mechanical seal leakagenone visible
Bearing housing temperatureambient + 20–40 °C; too hot to hold a hand on means check it with the IR gun
Motor amps vs nameplate60–95 % at normal flow
Suction strainer ΔP — clean / change over< 0.1 / 0.3 bar
PD relief valve setting10–15 % above working pressure

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Discharge pressure low, suction normal, amps lowDirection of rotation; discharge valveReverse rotation after motor work; worn impeller or wear rings; discharge valve throttledCorrect rotation; open valve; overhaul
Discharge pressure swinging, gravel noiseSuction gaugeCavitation — strainer blocked, suction valve partly shut, tank low, liquid hot or viscousClear suction; slow down; cool or heat the liquid
Suction vacuum higher than usualStrainer ΔP; tank levelStrainer loading; suction line partly blocked; tank running lowChange over strainer; sound the tank
Pump runs, no flow, amps lowSuction gauge; vent cockLost prime — air in casing, foot valve passing, suction leakVent and prime; find the air leak
Pump runs, no flow, amps highDischarge valve; couplingDischarge shut; impeller jammed; PD pump dead-headedOpen discharge; stop and inspect
Gland hot, drip stoppedPacking gland nutsOver-tightened packing; dry packingBack off nuts; repack if scored
Gland streamingPackingPacking worn, shaft sleeve scoredRepack; sleeve if scored
Mechanical seal drippingSeal faces; product temperatureFaces worn or cracked; run dry once; wrong seal for liquidReplace seal cartridge
Bearing hotGrease level; coupling alignmentOver- or under-greased; misalignment; bearing failingCorrect grease; realign; replace bearing
Vibration new or risingCoupling; mounting bolts; impeller balanceMisalignment; loose bolts; impeller damage or foulingRealign; tighten; inspect impeller
Motor trips on overloadAmps; rotation; liquid densityWrong rotation; blocked impeller; heavier liquid than design; motor faultCorrect cause before reset
PD pump pressure falls as oil warmsOil viscosityNormal — thin oil slips past worn clearances; pump wornTrend it; overhaul when it can't make pressure hot
PD relief valve lifting continuouslyDischarge pathDownstream valve shut or filter blocked; relief set too lowOpen the path; reset relief
Standby pump won't take load in parallelDischarge check valve; impeller conditionCheck valve stuck; weaker pump held closed by the stronger oneFree the check valve; overhaul the weak pump

Draft: this page is drawn from the book manuscript and is still being checked.