Everything between the engine's output flange and the water: the shaft line that carries torque aft and thrust forward into the hull, the bearings and seals that let it turn, and the propeller. Most of it runs for years untouched, so the watch is temperatures, levels, and trends rather than adjustments.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Thrust bearing pad temperature | 45–70 °C; alarm around 75–80 °C |
| Plummer bearing temperature | 40–60 °C |
| Stern tube aft bearing temperature | 35–55 °C |
| Reduction gear LO pressure | 1.5–4 bar |
| Reduction gear LO inlet / outlet | 40–50 °C / up to 65 °C |
| Stern tube header tank | steady; 0.2–0.5 bar over sea pressure at the aft seal |
| Stern tube oil consumption | 0–2 L/day — the trend, not the number |
| CPP system pressure | 25–60 bar |
| CPP full ahead to full astern | 15–30 s |
| Shaft-to-hull voltage, brush fitted | below 50 mV; act above 100 mV |
| Bow thruster use | ship speed under about 5 kn |
The plant, stop by stop, as the book walks it.
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| One thrust pad hotter than the rest | The other pads; LO inlet temp | Pad wiping; dirt; misalignment | Reduce load; trend hourly; inspect at first stop |
| Plummer bearing hot | Oil level; ring turning; cooling water | Low oil; stuck ring; cooling off; alignment | Top up; cooling on; alignment at docking |
| Stern tube header level falling | Aft seal drain tank; forward seal drain tank | Aft lips worn; forward seal; pipe leak | Log every liter; forward seal change; dive |
| Stern tube header level rising, oil milky | Bottom drain sample | Seawater past the aft seal | Drain daily; chloride test; plan docking |
| Aft seal drain tank filling with water | Chloride test on it | Outer lips gone | Empty and log daily; dive or docking |
| Gear chip detector alarm or sound changed | Pull the plug; rpm where it changes | Bearing; tooth; coupling; wear fuzz | Identify debris; reduce load; inspect through cover |
| CPP slow to respond | Pressure; filter ΔP; pump | Pump worn; filter; servo valve; OD box leak | Standby pump; filter; cartridge |
| CPP pitch not matching demand, pressure normal | Feedback vs mechanical indicator | Feedback transmitter; signal; servo valve | Local emergency control; calibrate feedback |
| New vibration at one rpm band only | Where it is felt; rpm limits | Resonance; propeller damage or fouling; loose bearing bolt | Stay out of the band; dive inspection |
| Water in the aft seal tank soon after an oil change | Oil type against seal maker's approval | EAL incompatible with seal material | Sample; maker; plan docking |
| Header tank high underway, nothing added | When and how it was last filled | Filled cold above the cold mark | Drain back to the mark; fill only to the cold mark |
| Plummer bearing throwing oil at the ends | Bath level | Overfilled; end seal worn | Drain to the mark; small logged top-ups |
| Shaft-to-hull mV high | Brushes; slip ring | Brushes worn or lifted; ring dirty | Clean ring; change brushes |
| Bow thruster trips on overload | Pitch; ship speed; generators on line | Too much pitch at speed; PMS limit | Less pitch; second generator |
Work out what you’d do, then open it.
Some months after the stern tube was changed over to an EAL, the aft seal tank starts showing water. The forward seal tank stays full of clean oil and the header tank is steady. Next docking is a year away. What is going on, and what do you do?
The aft seals are failing, and the timing points at the oil change: EAL that isn't compatible with the seal material degrades all the aft seals together, not one lip. Empty and log the tank daily — the rate is your gauge, and a jump means the last lip is going. Sample the stern tube oil for water, get the seal maker's view on compatibility, and plan the docking from the trend, not the calendar. Before any change of stern tube oil, confirm compatibility with the seal maker first.
The reduction gear chip detector alarms at sea, full away, no change in sound or temperatures. What do you do?
Pull the plug. Gray fuzz you can wipe off is wear and goes in the log. Flakes, slivers, or bright chips are a bearing or a tooth: reduce load, watch bearing temperatures and sound, and sample the oil for the lab. At the first stop, open the inspection cover and look at the mesh with a light. The alarm is the only early warning the gear gives.
Maneuvering in, the bridge calls for astern and the pitch indicator stays at 30 % ahead. CPP pressure normal, both pumps available. What do you do?
Pressure normal means the oil is there; the fault is in the control or the servo valve, or the feedback has frozen so the system thinks pitch is already where it was asked to go. Go to local emergency pitch control at the HPU now and take the bridge's orders by phone, with the engine side setting rpm — that is why it is tried before every arrival. Alongside, check the feedback transmitter against the mechanical indicator, then the servo valve. A transmitter worked loose on its drive is the usual answer.
The aft plummer bearing is at 85 °C and still climbing with the oil and cooling water confirmed. You have to stop the shaft. What else has to happen, and in what order?
Tell the bridge first — they are about to lose steerage way. On a CPP, pitch to zero before stopping the engine. Stop, then apply the shaft brake so the propeller does not windmill a shaft on a failed bearing; keep the gear LO pump running while things cool. Generators, steering, and the bow thruster are unaffected — the ship can be held or pointed, not driven.
Once cool, turn the shaft on the turning gear and feel whether it is free before anyone decides whether it turns again at sea.
Draft: this page is drawn from the book manuscript and is still being checked.