An oily water separator takes water from the bilge holding tank, lets the oil float out of it in two or three stages, and proves the result with a 15 ppm monitor before any of it goes overboard. Its place in the plant is Bilge, Stops 5 and 6.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Feed rate | At or below nameplate (0.25–5 m³/h); never above |
| Supply pressure into the unit | 1–3 bar |
| First-stage heater, where fitted | 30–60 °C; interlocked so it cannot heat an empty vessel |
| Coalescer ΔP, clean / change | 0.1–0.3 bar / maker's limit, often 0.5–1 bar |
| Oil discharge valve | Open for seconds to a minute, a few times an hour on ordinary bilge water |
| Monitor on clean bilge water | 0–5 ppm, steady |
| Monitor zero on fresh water | 0–2 ppm |
| Alarm set point | 15 ppm; valve and pump follow the alarm at once |
| Monitor record retained | 18 months |
| Calibration | Maker or approved service, certificate on board; never over 5 years |
| Lowest holding tank level for feed | About 1 m, or the maker's mark (see Bilge, Stop 4) |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| ppm high from the start, glass sample milky | Smell for soap; let the sample stand | Detergent in the bilge; oil sheared by a centrifugal transfer pump or hours of recirculation on a worn feed pump | Stop; this batch is landed, not separated; find the soap |
| ppm high from the start, glass sample clear | Fresh water flush and zero check | Fouled cell; bubbles in the sample; sample line not yet clear of the last run | Clean the cell, re-zero, vent the sample line |
| ppm fine for an hour, then climbs steadily | Holding tank sounding; element hours | Coalescer saturated; adsorption cartridge exhausted; oil layer at the tank suction; feed above rated | Stop; sound the tank; change elements on hours or ppm |
| ppm swings 0 to 30 and back every few seconds | Sample cell for bubbles; feed pump type | Air in the sample line; piston pump pulsation; suction leak drawing air | Vent the sample line; find the air; steady the sample flow |
| Coalescer ΔP high, flow falling | What the holding tank is full of | Solids blinding the fibers; feed too fast | Change element; find the solids source; run at rated flow |
| Coalescer ΔP low or zero, ppm rising | Element seating and gasket | Torn element; element not seated after a change; bypass gasket missing | Open the housing; refit or replace |
| Oil discharge valve opens constantly, water comes out | Probe tip | Probe fouled and reading oil; probe or cable failed; valve seat passing | Clean or replace the probe; overhaul the valve |
| Oil valve never opens; oil found in the coalescer housing | Probe, solenoid, air supply | Probe coated and reading water; solenoid dead; air off; oil too cold to reach the probe | Clean the probe; test the valve by hand; check the heater |
| Heater tripped or element burnt out | Vent cocks on the gravity stage | Vessel not vented after work; low-level interlock bypassed or failed | Vent until solid water; replace element; test the interlock |
| Feed pump noisy, suction deep, little flow | Suction strainer; valve bonnets; flushing water | Rags; strainer blocked; worn stator or piston valves; air leak on the suction; run without flushing water | Clean strainer; open bonnets; overhaul pump |
| Alarm sounds; three-way valve does not move | Air supply to the actuator; solenoid pilot | Air off; solenoid failed; actuator seized; position switch lying | Stop the pump by hand now; close overboard; repair before the next run |
| Monitor reads 0 ppm on everything | Sample flow indicator; flush valve | Sample line blocked; flush water passing; sample pump dead; cell drained | No discharge; restore and prove sample flow; glass sample |
Draft: this page is drawn from the book manuscript and is still being checked.