Part II · The Equipment · Family 2 · Clean It · Stage 2 · First month

Oily Water Separators

An oily water separator takes water from the bilge holding tank, lets the oil float out of it in two or three stages, and proves the result with a 15 ppm monitor before any of it goes overboard. Its place in the plant is Bilge, Stops 5 and 6.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Feed rateAt or below nameplate (0.25–5 m³/h); never above
Supply pressure into the unit1–3 bar
First-stage heater, where fitted30–60 °C; interlocked so it cannot heat an empty vessel
Coalescer ΔP, clean / change0.1–0.3 bar / maker's limit, often 0.5–1 bar
Oil discharge valveOpen for seconds to a minute, a few times an hour on ordinary bilge water
Monitor on clean bilge water0–5 ppm, steady
Monitor zero on fresh water0–2 ppm
Alarm set point15 ppm; valve and pump follow the alarm at once
Monitor record retained18 months
CalibrationMaker or approved service, certificate on board; never over 5 years
Lowest holding tank level for feedAbout 1 m, or the maker's mark (see Bilge, Stop 4)

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
ppm high from the start, glass sample milkySmell for soap; let the sample standDetergent in the bilge; oil sheared by a centrifugal transfer pump or hours of recirculation on a worn feed pumpStop; this batch is landed, not separated; find the soap
ppm high from the start, glass sample clearFresh water flush and zero checkFouled cell; bubbles in the sample; sample line not yet clear of the last runClean the cell, re-zero, vent the sample line
ppm fine for an hour, then climbs steadilyHolding tank sounding; element hoursCoalescer saturated; adsorption cartridge exhausted; oil layer at the tank suction; feed above ratedStop; sound the tank; change elements on hours or ppm
ppm swings 0 to 30 and back every few secondsSample cell for bubbles; feed pump typeAir in the sample line; piston pump pulsation; suction leak drawing airVent the sample line; find the air; steady the sample flow
Coalescer ΔP high, flow fallingWhat the holding tank is full ofSolids blinding the fibers; feed too fastChange element; find the solids source; run at rated flow
Coalescer ΔP low or zero, ppm risingElement seating and gasketTorn element; element not seated after a change; bypass gasket missingOpen the housing; refit or replace
Oil discharge valve opens constantly, water comes outProbe tipProbe fouled and reading oil; probe or cable failed; valve seat passingClean or replace the probe; overhaul the valve
Oil valve never opens; oil found in the coalescer housingProbe, solenoid, air supplyProbe coated and reading water; solenoid dead; air off; oil too cold to reach the probeClean the probe; test the valve by hand; check the heater
Heater tripped or element burnt outVent cocks on the gravity stageVessel not vented after work; low-level interlock bypassed or failedVent until solid water; replace element; test the interlock
Feed pump noisy, suction deep, little flowSuction strainer; valve bonnets; flushing waterRags; strainer blocked; worn stator or piston valves; air leak on the suction; run without flushing waterClean strainer; open bonnets; overhaul pump
Alarm sounds; three-way valve does not moveAir supply to the actuator; solenoid pilotAir off; solenoid failed; actuator seized; position switch lyingStop the pump by hand now; close overboard; repair before the next run
Monitor reads 0 ppm on everythingSample flow indicator; flush valveSample line blocked; flush water passing; sample pump dead; cell drainedNo discharge; restore and prove sample flow; glass sample

Draft: this page is drawn from the book manuscript and is still being checked.