The lube oil plant stores, transfers, cleans, and accounts for every grade of oil on the ship. It keeps the main engine sump clean enough to keep running, feeds cylinder oil at the right alkalinity for the fuel being burned, and tops up every other sump on board.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| System oil, crosshead engine | SAE 30, BN 5–10 |
| Trunk piston oil, HFO engines | SAE 40, BN 30–40 |
| Trunk piston oil, MGO-only engines | SAE 40, BN 12–20 |
| Cylinder oil feed rate | 0.6–1.0 g/kWh (older engines up to 1.5) |
| LO purifier inlet temperature | 85–95 °C |
| LO purifier back pressure | 1.5–2.2 bar |
| LO purifier throughput | 20–30 % of rating; sump turned over 3–5 times a day |
| Main engine sump temperature | 45–55 °C |
| Generator sump level | top up below ¼ on the dipstick; never above ¾ |
| System oil consumption, crosshead | 0.1–0.3 g/kWh |
| Aux engine oil consumption | 0.5–1.0 g/kWh |
| Water in system oil | < 0.2 % normal · 0.5 % act now |
| Viscosity, in service | within ±20 % of fresh |
| BN, in service | not below half of fresh |
| Flash point, system oil | > 180 °C |
| Iron, system oil | < 30–50 ppm crosshead · < 100 ppm trunk piston |
The plant, stop by stop, as the book walks it.
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Sump level falling, top-up rising | Sludge tank for oil; break-over line | Purifier seal lost; leak to bilge; stuffing box drains | Reseal purifier; walk save-alls and bilge; log top-up daily |
| Sump level rising, no top-up | Bottom drain cock; flash point | Cooler or jacket leak; fuel dilution | Drain water; sample; find the leak |
| Water at the sump drain | Onboard water test; sodium on next sample | Seawater — LO cooler; freshwater — jacket, piston cooling | Isolate the leaker; purifier to minimum throughput; renovate in batch above 0.5 % |
| Stopped engine's sump level rising | Fill valves to that engine | Gravity fill valve leaking by | Close; blank until repaired; drain the excess |
| Oil sheen in the cooling water expansion tank | Run one engine at a time; watch the tank | Generator LO cooler leaking | Change the cooler; test that sump for water |
| One generator using several times the others' oil | Blow-by at the dipstick | Worn rings and liners | Maneuvering only; plan overhaul |
| Purifier inlet won't hold temperature, engine stopped | Heater steam and trap; heater ΔT | Heater fouled; regulator stuck | Clean the heater; hold temperature by hand meanwhile |
| Oil in purifier sludge tank | Seal water; inlet temperature; gravity disc | Seal lost; too hot; wrong disc | Reseal; reset temperature; refit correct disc |
| Flash point down, level steady | Fuel pump and injector leak-off; stuffing box drain | Fuel dilution | Find the leak; change oil below maker's limit |
| Iron rising on lab report | Scrape-down iron; cylinder oil BN and feed | Liner wear from wrong BN or low feed | Correct BN and feed; liner inspection through scavenge ports |
| Cylinder oil consumption down, no setting change | Each lubricator pumping; daily tank suction | Air lock; blocked line; controller fault | Vent; confirm every unit; check liner temperatures |
| Cylinder oil daily tank overflowing | Pump mode; auto-stop float | Auto-stop stuck; pump left in manual | Stop the fill; free and test the stop |
| Stern tube header level falling | Forward seal drain; aft seal drain tank | Aft seal leaking to sea | Top up and log; report to Chief; plan seal change |
| Water in stern tube oil after an oil change | Oil type against seal maker's list | Seals incompatible with the new oil | Report; sample daily; plan docking |
Work out what you’d do, then open it.
Main engine system oil top-up has gone from 90 L a day to 125 L over a week. Same load, no water in the drains. Where did it go?
Oil leaves a crosshead engine four ways: purifier sludge, stuffing box drains, leaks, and the cylinders. Sludge tank sight glass first — oil on top means the purifier lost its seal. Then the stuffing box drain tank. Then the usual leakers: filter lids, LO and purifier feed pumps, piston-underside doors, turbocharger bases, hydraulic exhaust valve actuators where fitted. Anything in the bilge goes in the ORB.
An oil sheen comes and goes in the expansion tank shared by several generators. The weekly log shows every generator under 1 % water. A lab sample from one set reads over 5 %. What is going on?
One generator LO cooler is leaking both ways — oil into the cooling water when the engine runs, water into the oil when it stops. The log missed it because samples came from the dipstick tube. Run one engine at a time and watch the expansion tank. Don't try to purify it out with the leak still open; a full day gets the water down to a few tenths at best. Change the cooler, drain the sump to the oily bilge tank, fresh oil and filters. Move every sample point to a live line.
Daily tank top-up has dropped from 200 L to 140 L over two days with no change in load or setting. The Chief calls it good news. Is it?
No. Consumption only drops on its own when oil is not reaching the liners. Check every lubricator is pumping and vent the daily tank suction. A starved cylinder's liner runs hot. After a changeover on a two-oil ship, confirm the low-BN tank is feeding. Treat it as a scuffing risk until you have found the oil.
The only LO purifier trips on vibration at 0200 and needs a bowl strip-down. The main engine stays on continuous running. What stops, and in what order?
Nothing stops now. Over the next days water and insolubles climb as fast as the engine lets them in. Crack the sump drain and read engine LO filter ΔP each watch. In port the sump also loses its heater. If there is a generator purifier, flush it and line it up to the main sump. If water passes 0.5 % with no purifier, the engine comes down to renovate the charge in batch — a ship stopped at sea.