Part I · The Plants

Lube Oil Plant

The lube oil plant stores, transfers, cleans, and accounts for every grade of oil on the ship. It keeps the main engine sump clean enough to keep running, feeds cylinder oil at the right alkalinity for the fuel being burned, and tops up every other sump on board.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
System oil, crosshead engineSAE 30, BN 5–10
Trunk piston oil, HFO enginesSAE 40, BN 30–40
Trunk piston oil, MGO-only enginesSAE 40, BN 12–20
Cylinder oil feed rate0.6–1.0 g/kWh (older engines up to 1.5)
LO purifier inlet temperature85–95 °C
LO purifier back pressure1.5–2.2 bar
LO purifier throughput20–30 % of rating; sump turned over 3–5 times a day
Main engine sump temperature45–55 °C
Generator sump leveltop up below ¼ on the dipstick; never above ¾
System oil consumption, crosshead0.1–0.3 g/kWh
Aux engine oil consumption0.5–1.0 g/kWh
Water in system oil< 0.2 % normal · 0.5 % act now
Viscosity, in servicewithin ±20 % of fresh
BN, in servicenot below half of fresh
Flash point, system oil> 180 °C
Iron, system oil< 30–50 ppm crosshead · < 100 ppm trunk piston

The tour

The plant, stop by stop, as the book walks it.

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Sump level falling, top-up risingSludge tank for oil; break-over linePurifier seal lost; leak to bilge; stuffing box drainsReseal purifier; walk save-alls and bilge; log top-up daily
Sump level rising, no top-upBottom drain cock; flash pointCooler or jacket leak; fuel dilutionDrain water; sample; find the leak
Water at the sump drainOnboard water test; sodium on next sampleSeawater — LO cooler; freshwater — jacket, piston coolingIsolate the leaker; purifier to minimum throughput; renovate in batch above 0.5 %
Stopped engine's sump level risingFill valves to that engineGravity fill valve leaking byClose; blank until repaired; drain the excess
Oil sheen in the cooling water expansion tankRun one engine at a time; watch the tankGenerator LO cooler leakingChange the cooler; test that sump for water
One generator using several times the others' oilBlow-by at the dipstickWorn rings and linersManeuvering only; plan overhaul
Purifier inlet won't hold temperature, engine stoppedHeater steam and trap; heater ΔTHeater fouled; regulator stuckClean the heater; hold temperature by hand meanwhile
Oil in purifier sludge tankSeal water; inlet temperature; gravity discSeal lost; too hot; wrong discReseal; reset temperature; refit correct disc
Flash point down, level steadyFuel pump and injector leak-off; stuffing box drainFuel dilutionFind the leak; change oil below maker's limit
Iron rising on lab reportScrape-down iron; cylinder oil BN and feedLiner wear from wrong BN or low feedCorrect BN and feed; liner inspection through scavenge ports
Cylinder oil consumption down, no setting changeEach lubricator pumping; daily tank suctionAir lock; blocked line; controller faultVent; confirm every unit; check liner temperatures
Cylinder oil daily tank overflowingPump mode; auto-stop floatAuto-stop stuck; pump left in manualStop the fill; free and test the stop
Stern tube header level fallingForward seal drain; aft seal drain tankAft seal leaking to seaTop up and log; report to the engineer in charge; plan seal change
Water in stern tube oil after an oil changeOil type against seal maker's listSeals incompatible with the new oilReport; sample daily; plan docking

Scenarios

Work out what you’d do, then open it.

consumption up

Main engine system oil top-up has gone from 90 L a day to 125 L over a week. Same load, no water in the drains. Where did it go?

Oil leaves a crosshead engine four ways: purifier sludge, stuffing box drains, leaks, and the cylinders. Sludge tank sight glass first — oil on top means the purifier lost its seal. Then the stuffing box drain tank. Then the usual leakers: filter lids, LO and purifier feed pumps, piston-underside doors, turbocharger bases, hydraulic exhaust valve actuators where fitted. Anything in the bilge goes in the ORB.

oil in the cooling water, water in the oil

An oil sheen comes and goes in the expansion tank shared by several generators. The weekly log shows every generator under 1 % water. A lab sample from one set reads over 5 %. What is going on?

One generator LO cooler is leaking both ways — oil into the cooling water when the engine runs, water into the oil when it stops. The log missed it because samples came from the dipstick tube. Run one engine at a time and watch the expansion tank. Don't try to purify it out with the leak still open; a full day gets the water down to a few tenths at best. Change the cooler, drain the sump to the oily bilge tank, fresh oil and filters. Move every sample point to a live line.

cylinder oil consumption down

Daily tank top-up has dropped from 200 L to 140 L over two days with no change in load or setting. The engineer in charge calls it good news. Is it?

No. Consumption only drops on its own when oil is not reaching the liners. Check every lubricator is pumping and vent the daily tank suction. A starved cylinder's liner runs hot. After a changeover on a two-oil ship, confirm the low-BN tank is feeding. Treat it as a scuffing risk until you have found the oil.

purifier down

The only LO purifier trips on vibration at 0200 and needs a bowl strip-down. The main engine stays on continuous running. What stops, and in what order?

Nothing stops now. Over the next days water and insolubles climb as fast as the engine lets them in. Crack the sump drain and read engine LO filter ΔP each watch. In port the sump also loses its heater. If there is a generator purifier, flush it and line it up to the main sump. If water passes 0.5 % with no purifier, the engine comes down to renovate the charge in batch — a ship stopped at sea.

Dependencies

Needs
  • Electrical — transfer pumps, purifier, electric heaters
  • Steam — purifier heater and tank heating on steam-heated ships
  • LT cooling water — LO coolers at the engines
  • Control air and operating water — purifier
  • Fuel plant — the sulfur number that sets the cylinder oil
Feeds
  • Main engine — system oil sump, cylinder oil, turbocharger sump
  • Every generator engine, and governors
  • Stern tube bearings and seals; reduction gear where fitted
  • Hydraulic reservoirs and deck machinery top-ups
  • Waste oil, sludge, and the Oil Record Book

Draft: this page is drawn from the book manuscript and is still being checked.