Part II · The Equipment · Family 2 · Clean It · Stage 3 · First hitch

Incinerators

An incinerator burns the ship's own sludge and solid garbage to ash and flue gas so less goes ashore. It is a refractory-lined furnace with a diesel burner to light it, a sludge burner to feed it, fans for air and draft, and a controller that won't let it run outside its approved temperatures; its place in the sludge system is in Bilge, Stop 9.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Chamber, running / high trip850–1,100 / 1,200–1,300 °C
Chamber before sludge is admitted600–850 °C by maker
Flue gas after dilution air250–350 °C; alarm about 400 °C
Chamber draft−5 to −25 mm H₂O
Water in sludgebelow the maker's limit, often 30–50 %
Atomizing air4–7 bar
Pilot burner fuel pressure8–20 bar
Loading door interlocklocked above about 170–220 °C; burners stop when it opens
Cool-down on fans1–3 h

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Won't start, no pre-purgeLockout; door switches; flue gas fanLockout not reset; door switch; fan tripped; fire-system trip relay still madeReset; prove the fan; reset the trip relay
Purge, no ignition, lockoutSpark at the sight glass; diesel pressureElectrodes fouled or cracked; transformer; nozzle blocked; solenoid; air in the lineClean and set electrodes; nozzle; bleed
Lights, then flame failure in secondsScanner; start airDirty scanner; too much air; poor sprayClean the scanner; reduce start air; nozzle
Flame failure when sludge comes onService tank drain; atomizing airWater slug; air low; sludge cold; nozzle blockedDrain; raise air and temperature; nozzle; restart on diesel
Won't reach pre-heat temperaturePilot nozzle and pressure; dampersWeak pilot; too much air; door seal leaking; wet refractoryNozzle and pressure; dampers; seal
Chamber climbing with dosing at minimumTank contentsDry oil, no water; dosing pump passing; nozzle wornSludge off; diesel only; check the pump minimum
Flue gas high, chamber normalDilution damper by handDamper stuck; fan weak; thermocoupleFree the damper; fan belt and impeller; prove the thermocouple
Draft lost, smoke at the doorFlue gas fan; uptakeBelt slipping; impeller sooted; damper shut; uptake blockedStop; clean fan and uptake
Casing hot spotRefractory behind itCrack through; spall; slag pocketFinish on diesel; inspect cold; patch
Door won't release after cool-downFans; thermocouple against an IR gunFans stopped early; thermocouple high; latch solenoidFans on and wait; prove the thermocouple; manual release per manual
Ignition transformer burns out repeatedlyDoes it drop out after flame is proved?Sequence in manual; "flame proved" input missingFix the input before the next transformer