An incinerator burns the ship's own sludge and solid garbage to ash and flue gas so less goes ashore. It is a refractory-lined furnace with a diesel burner to light it, a sludge burner to feed it, fans for air and draft, and a controller that won't let it run outside its approved temperatures; its place in the sludge system is in Bilge, Stop 9.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Chamber, running / high trip | 850–1,100 / 1,200–1,300 °C |
| Chamber before sludge is admitted | 600–850 °C by maker |
| Flue gas after dilution air | 250–350 °C; alarm about 400 °C |
| Chamber draft | −5 to −25 mm H₂O |
| Water in sludge | below the maker's limit, often 30–50 % |
| Atomizing air | 4–7 bar |
| Pilot burner fuel pressure | 8–20 bar |
| Loading door interlock | locked above about 170–220 °C; burners stop when it opens |
| Cool-down on fans | 1–3 h |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Won't start, no pre-purge | Lockout; door switches; flue gas fan | Lockout not reset; door switch; fan tripped; fire-system trip relay still made | Reset; prove the fan; reset the trip relay |
| Purge, no ignition, lockout | Spark at the sight glass; diesel pressure | Electrodes fouled or cracked; transformer; nozzle blocked; solenoid; air in the line | Clean and set electrodes; nozzle; bleed |
| Lights, then flame failure in seconds | Scanner; start air | Dirty scanner; too much air; poor spray | Clean the scanner; reduce start air; nozzle |
| Flame failure when sludge comes on | Service tank drain; atomizing air | Water slug; air low; sludge cold; nozzle blocked | Drain; raise air and temperature; nozzle; restart on diesel |
| Won't reach pre-heat temperature | Pilot nozzle and pressure; dampers | Weak pilot; too much air; door seal leaking; wet refractory | Nozzle and pressure; dampers; seal |
| Chamber climbing with dosing at minimum | Tank contents | Dry oil, no water; dosing pump passing; nozzle worn | Sludge off; diesel only; check the pump minimum |
| Flue gas high, chamber normal | Dilution damper by hand | Damper stuck; fan weak; thermocouple | Free the damper; fan belt and impeller; prove the thermocouple |
| Draft lost, smoke at the door | Flue gas fan; uptake | Belt slipping; impeller sooted; damper shut; uptake blocked | Stop; clean fan and uptake |
| Casing hot spot | Refractory behind it | Crack through; spall; slag pocket | Finish on diesel; inspect cold; patch |
| Door won't release after cool-down | Fans; thermocouple against an IR gun | Fans stopped early; thermocouple high; latch solenoid | Fans on and wait; prove the thermocouple; manual release per manual |
| Ignition transformer burns out repeatedly | Does it drop out after flame is proved? | Sequence in manual; "flame proved" input missing | Fix the input before the next transformer |
Draft: this page is drawn from the book manuscript and is still being checked.