Hydraulic Pumps and Motors

A hydraulic pump turns shaft torque into oil flow; the load downstream turns that flow into pressure. A hydraulic motor is the same machine run the other way — oil in, torque out. Nearly every pump complaint is answered by four readings at the pump itself: delivery pressure, the case drain, the noise, and the temperature of the case.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Gear pump, continuous pressureup to 150–250 bar
Vane pump, continuous pressureup to 100–175 bar
Axial piston pump, continuous / peak250–350 bar / 400 bar and above
Radial piston pump300–700 bar
Volumetric efficiency, new — gear / vane / piston85–95 % / 90–95 % / 95–98 %
Piston pump case drain, new / replace1–3 % of delivery / about 10 %
Case drain line temperaturewithin about 10 °C of the reservoir
Case drain back pressure at the pumpunder 0.5–2 bar; the shaft seal sets the limit
Inlet pressure, piston pump0.8 bar absolute minimum (about −0.2 bar gauge); many want a flooded or boosted inlet
Oil viscosity, running / cold start maximum16–36 cSt / 1000 cSt
Relief setting above compensator setting10–20 %
Load-sense margin (standby pressure)14–25 bar
Oil cleanliness (ISO 4406) — gear and vane / piston / servo20/18/15 / 18/16/13 / 16/14/11

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
High whine rising with speed, pressure gauge shakingSuction strainer; suction valve; breather; oil temperatureCavitationClear the inlet; warm the oil; slow it down
Crackling, foam in the tank, spongy functionsLevel; suction fittings; return pipe position; shaft sealAerationTop up; tighten; renew seal; return below the surface
Pressure won't reach setpoint, pump quietRelief temperature; compensator; couplingRelief passing; compensator stuck destroked; pump worn; coupling slippingIR gun on relief; gauge on compensator; look at the coupling
Setpoint reached, functions slow under loadCase drain temperature and flowPump worn — makes pressure, can't make flowMeasure case drain; plan replacement
Case drain hot at standby, nothing movingCase drain vs reservoir temperatureInternal leakage past pistons and slippers; compensator spool leakingCase drain flow test
Pressure hunting ±10–20 bar at steady loadCompensator and relief settingsSettings too close; compensator spool sticking; accumulator precharge lowSet relief 10–20 % above compensator; clean spool
Load-sensing pump at margin, function crawlsGauge on LS port vs outletLS line blocked or leaking; shuttle stuck; LS relief lowCompare the two gauges; clear the LS line
New pump whines, no pressure, seal pushed outCase fill; drain route; rotationStarted with an empty case; drain blocked or into a pressure line; wrong rotationStop; fill case; re-route drain; check rotation
Metal in the pressure filter, pump noisyStop itPump breaking upReplace; flush; new filter; sample before running
Hydraulic motor slow and hot, pressure at reliefBrake housing vs motor case temperatureMotor worn; brake dragging; counterbalance valveCase drain flow; release brake and compare
Motor overruns on lowering, cavitates, chattersCounterbalance or brake valveValve setting; spring broken; spool stuckSet per maker; renew cartridge
Shaft seal weeping on a motorCase drain back pressureDrain line too long, too small, or shared with a hot returnSeparate drain to tank; check back pressure