Hotel equipment feeds and cleans the crew and keeps the cabins livable. It belongs to no family and to someone else's department, and most of its calls are the same dozen faults.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Galley supply | 440 V three-phase for ranges, ovens, fryers, dishwashers; 220 V (120 V on some ships) for small appliances |
| Fryer oil, cooking / high limit | 160–190 °C / trips at 200–230 °C, hand reset |
| Dishwasher wash / final rinse | 55–70 °C / 82 °C or above |
| Booster heater rise | 20–40 °C over the incoming hot water |
| Self-contained electric kettle, cold | gauge in vacuum; zero means air in the jacket |
| Ice machine freeze / harvest | 15–30 min / 1–3 min |
| Hot water, calorifier / loop return | 60–65 °C / above 50 °C |
| Cabin supply air | 12–16 °C |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Whole galley dead | Feeder breakers | Tripped; not restarted after blackout | Reset; find why before the second time |
| One hotplate or oven dead or cool | Element; switch; phases | Element open; infinite switch or thermostat; burnt terminal | Renew |
| Kettle jacket cold at the bottom | Trap outlet | Trap failed shut; strainer; air in jacket | Test or change trap |
| Fryer oil smokes at a normal setting | Oil thermometer | Thermostat drifted or welded | Breaker off; renew; prove the high limit |
| Fryer won't heat | High-limit reset | High limit tripped; element; contactor | Find why it tripped first |
| Rinse below 82 °C | Booster temp and amps; incoming water | Scale; element open; cold supply; rinse pressure high | Descale; renew; check supply |
| Dishes dirty | Arms; screens; chemicals | Nozzles blocked; pump strainer; drum empty | Clean; check dosing |
| Ice slow, thin, or none | Condenser; water filter | Dirty coil; scale; blocked filter; low charge | Clean; descale |
| Washer won't drain | Drain valve; strainer | Valve stuck; strainer full of lint and socks | Clear; renew diaphragm |
| Washer trips on balance | Load | Unbalanced or overloaded; worn suspension | Redistribute; renew |
| Dryer slow, trips on high limit | Lint path; duct outlet | Screen, cavity, or duct blocked; belt slipping | Clean the whole path now |
| Water from a cabin ceiling | Condensate drain | Drain pan or trap blocked; coil icing on dirty filter | Clear; change filter |
| One cabin hot | Damper; reheater | Damper moved; reheater stuck on; filter | Reset; repair |
| Galley sinks back up | Grease trap; line | Grease; food solids; tank vent | Clear trap; rod line; see Sewage and Gray Water, Stop 7 |