The freshwater plant makes distilled water from seawater, turns part of it into drinking water, and delivers it under pressure, hot and cold, through the ship. The rest feeds the boiler, the cooling systems, and the washdown line.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Evaporator vacuum | 85–93 % |
| Evaporator shell temperature | 44–46 °C; scale builds fast above 48 °C |
| HT water in / out of evaporator | 80–85 / 70–78 °C |
| Ejector pump pressure | 3–4 bar |
| Evaporator output | 15–30 t/day |
| RO feed pressure (seawater) | 55–70 bar |
| RO permeate conductivity | < 500 µS/cm |
| Salinity dump set point, evaporator | 2–10 ppm |
| Potable water pH | 7–8.5 |
| Free chlorine residual at the tap (chlorinated systems) | 0.2–0.5 ppm |
| UV sterilizer intensity | about 90 %; alarm or trip near 50 % |
| Hydrophore cut-in / cut-out | 4 / 6 bar |
| Hydrophore water level at cut-out | ½–¾ of the glass |
| Hot water at the calorifier outlet | 60–65 °C |
| Hot water loop return | ≥ 50 °C |
The plant, stop by stop, as the book walks it.
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Evaporator output down, vacuum normal | HT in and out; shell temp | Scale; low engine load; HT throttled | Compare HT ΔT to baseline; descale |
| Evaporator output down, vacuum low | Ejector pump pressure | Air leak; ejector worn; strainer | Soap test; strainer; renew nozzle |
| ME jacket temp rising during evaporator secure | Bypass and HT valve positions | HT closed with bypass throttled | Open bypass; one notch a minute |
| JW head tank top-ups increasing | Brine and distillate | Evaporator plate or gasket leak; head gasket | Rule out the evaporator first |
| Salinity alarm, dump valve opened | Brine level; what's going overboard | Carryover; dirty discharge near the sea chest; demister | Reduce feed; change sea chest; inspect |
| Salinity creeping, no alarm | Probe condition | Probe fouled; set point wrong | Clean probe; test the alarm now |
| RO permeate down, pressure up | Pre-filter ΔP | Membrane fouling | Clean membranes |
| UV sterilizer tripped | Intensity; recent backflush | Backflush stirred up the water; lamp aged; sleeve fouled | Reset after flush; sleeve; lamp |
| Water tastes flat or metallic | pH; rehardening filter | Bed exhausted | Replace bed |
| Water smells stale | Tank in use; dead legs | Slime in tank; no residual | Clean tank; disinfect; flush dead legs |
| Potable tank level shifting on its own | Suction valves | Two suctions open — tanks equalizing | Close one |
| Water appearing beside a potable tank | Gauge glass fittings | Tank overfilled | Hold level below the glass top; repair |
| Hydrophore pump short-cycling | Water level in the glass | Air cushion gone | Draw down; add air |
| Hydrophore needs air daily | Fittings, auto-air valve | Air leak; waterlogged vessel | Find the leak |
| No hot water, cold fine | Calorifier temp; element amps; circ pump | Elements burnt; auto control failed; pump stopped | Restore heat; manual on the round sheet |
Work out what you’d do, then open it.
Arrival. You open the evaporator bypass and start closing HT in and out. Two minutes later the ME jacket outlet temperature alarm comes in and HT pressure is falling. What did you do, and what now?
Either the bypass was still throttled when the HT valves closed, or it all happened too fast for the engine's temperature control to follow. The HT flow had nowhere to go, pressure dropped, and the engine is heading for a slowdown. Open the bypass fully, stop closing, and let jacket temperature settle. Then close HT in and out one notch a minute while you watch it.
At sea, the evaporator salinity climbs from 2 to 9 ppm in half an hour. Vacuum and brine level are normal. On deck, the crew is pumping a dirty engine drain tank overboard with a fire pump. Connected?
Probably. If the discharge is on the same side as the evaporator's sea chest, the plant is drawing in what you're pumping out. Confirm the dump valve has actually gone to drain, then stop the pump-out or shift it to the opposite sea chest. Watch salinity settle before you make to tank again. If it doesn't settle with clean feed, look at the demister and the condenser.
The JW head tank needs topping up more often each week. No leak in the engine room. Where's the water going?
The usual suspects are an internal cylinder head gasket leak and a leaking evaporator heating plate or gasket — jacket water passing to the seawater side and away with the brine. The evaporator is the easier fix, so rule it out first: secure its HT supply for a day and see whether the losses stop. Log every top-up with the quantity, and tell the engineer in charge when they rise. Losing jacket water also means losing its treatment.
The main engine is stopped for a liner change at anchor for three days. What stops in the freshwater plant, in what order, and what do you do about it?
The evaporator stops with the engine — no HT heat. The potable tanks hold what they hold; a full pair usually lasts a week or more. RO, if fitted, runs on electricity, if the anchorage water is clean enough. Without RO, ration deck washing and laundry, and arrange a water barge if the stay stretches. Boiler and cooling makeup draw on stored distillate, which is why you sent evaporator output to the boiler feed tank before arrival; don't top the boiler up from potable. Keep the calorifiers hot.