Freshwater Plant

The freshwater plant makes distilled water from seawater, turns part of it into drinking water, and delivers it under pressure, hot and cold, through the ship. The rest feeds the boiler, the cooling systems, and the washdown line.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Evaporator vacuum85–93 %
Evaporator shell temperature44–46 °C; scale builds fast above 48 °C
HT water in / out of evaporator80–85 / 70–78 °C
Ejector pump pressure3–4 bar
Evaporator output15–30 t/day
RO feed pressure (seawater)55–70 bar
RO permeate conductivity< 500 µS/cm
Salinity dump set point, evaporator2–10 ppm
Potable water pH7–8.5
Free chlorine residual at the tap (chlorinated systems)0.2–0.5 ppm
UV sterilizer intensityabout 90 %; alarm or trip near 50 %
Hydrophore cut-in / cut-out4 / 6 bar
Hydrophore water level at cut-out½–¾ of the glass
Hot water at the calorifier outlet60–65 °C
Hot water loop return≥ 50 °C

The tour

The plant, stop by stop, as the book walks it.

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Evaporator output down, vacuum normalHT in and out; shell tempScale; low engine load; HT throttledCompare HT ΔT to baseline; descale
Evaporator output down, vacuum lowEjector pump pressureAir leak; ejector worn; strainerSoap test; strainer; renew nozzle
ME jacket temp rising during evaporator secureBypass and HT valve positionsHT closed with bypass throttledOpen bypass; one notch a minute
JW head tank top-ups increasingBrine and distillateEvaporator plate or gasket leak; head gasketRule out the evaporator first
Salinity alarm, dump valve openedBrine level; what's going overboardCarryover; dirty discharge near the sea chest; demisterReduce feed; change sea chest; inspect
Salinity creeping, no alarmProbe conditionProbe fouled; set point wrongClean probe; test the alarm now
RO permeate down, pressure upPre-filter ΔPMembrane foulingClean membranes
UV sterilizer trippedIntensity; recent backflushBackflush stirred up the water; lamp aged; sleeve fouledReset after flush; sleeve; lamp
Water tastes flat or metallicpH; rehardening filterBed exhaustedReplace bed
Water smells staleTank in use; dead legsSlime in tank; no residualClean tank; disinfect; flush dead legs
Potable tank level shifting on its ownSuction valvesTwo suctions open — tanks equalizingClose one
Water appearing beside a potable tankGauge glass fittingsTank overfilledHold level below the glass top; repair
Hydrophore pump short-cyclingWater level in the glassAir cushion goneDraw down; add air
Hydrophore needs air dailyFittings, auto-air valveAir leak; waterlogged vesselFind the leak
No hot water, cold fineCalorifier temp; element amps; circ pumpElements burnt; auto control failed; pump stoppedRestore heat; manual on the round sheet

Scenarios

Work out what you’d do, then open it.

ME overheats while you secure the evaporator

Arrival. You open the evaporator bypass and start closing HT in and out. Two minutes later the ME jacket outlet temperature alarm comes in and HT pressure is falling. What did you do, and what now?

Either the bypass was still throttled when the HT valves closed, or it all happened too fast for the engine's temperature control to follow. The HT flow had nowhere to go, pressure dropped, and the engine is heading for a slowdown. Open the bypass fully, stop closing, and let jacket temperature settle. Then close HT in and out one notch a minute while you watch it.

salinity rising after a pump-out

At sea, the evaporator salinity climbs from 2 to 9 ppm in half an hour. Vacuum and brine level are normal. On deck, the crew is pumping a dirty engine drain tank overboard with a fire pump. Connected?

Probably. If the discharge is on the same side as the evaporator's sea chest, the plant is drawing in what you're pumping out. Confirm the dump valve has actually gone to drain, then stop the pump-out or shift it to the opposite sea chest. Watch salinity settle before you make to tank again. If it doesn't settle with clean feed, look at the demister and the condenser.

jacket water disappearing

The JW head tank needs topping up more often each week. No leak in the engine room. Where's the water going?

The usual suspects are an internal cylinder head gasket leak and a leaking evaporator heating plate or gasket — jacket water passing to the seawater side and away with the brine. The evaporator is the easier fix, so rule it out first: secure its HT supply for a day and see whether the losses stop. Log every top-up with the quantity, and tell the engineer in charge when they rise. Losing jacket water also means losing its treatment.

HT system down

The main engine is stopped for a liner change at anchor for three days. What stops in the freshwater plant, in what order, and what do you do about it?

The evaporator stops with the engine — no HT heat. The potable tanks hold what they hold; a full pair usually lasts a week or more. RO, if fitted, runs on electricity, if the anchorage water is clean enough. Without RO, ration deck washing and laundry, and arrange a water barge if the stay stretches. Boiler and cooling makeup draw on stored distillate, which is why you sent evaporator output to the boiler feed tank before arrival; don't top the boiler up from potable. Keep the calorifiers hot.

Dependencies

Needs
  • HT cooling water at load — evaporator heat (see Seawater and Central Cooling)
  • Seawater from the running sea chest — feed and condenser cooling
  • Electrical — ejector, distillate, HP, hydrophore, dosing, and circulating pumps; UV
  • Service air — hydrophore air cushion
  • Steam or electricity — calorifiers
  • Clean sea — offshore position before starting
Feeds
  • Crew — drinking, galley, washing
  • Boiler feedwater makeup
  • Cooling water makeup for the HT and LT circuits
  • Laundry, washdown, technical water
  • Sewage plant flushing water
  • Main engine jacket water cooling — the evaporator takes heat out, so jacket temperature moves when it starts or stops