Part II · The Equipment · Family 3 · Heat It or Cool It · Stage 2 · First month

Freshwater Generators and RO Units

A freshwater generator boils seawater under vacuum with jacket water heat and condenses the vapor; a reverse osmosis unit pushes seawater through a membrane that holds the salt back. Both are judged by output and by the salt that gets through, and both die of scale or fouling on a surface you can't see.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Time to full vacuum after the ejector pump starts10–15 min; longer is an air leak
Shell temperature vs vacuum44–46 °C at about 90 % — they move together
Feed-to-distillate ratioabout 2–3:1
Brine concentrationabout 1.5–2× seawater
Brine level in the shell glassMaker's mark; above is carryover, below is bare heating surface
Ejector back pressure, overboard linebelow about 0.6 bar
Rated output falls off above seawaterabout 30–32 °C
Anti-scale dosing, 20–30 t/day unitroughly 0.5–1 L/day by the maker's chart
RO recovery (permeate ÷ feed)25–40 %
RO cartridge pre-filter5 µm; change at 0.7–1.0 bar ΔP or 2× clean
RO feed temperature5–40 °C; permeate changes about 3 % per °C
Free chlorine at the membranes0 — polyamide membranes don't survive it
RO clean atnormalized permeate down 10–15 %, or feed-to-brine ΔP up 15 %
RO flush on shutdownpermeate, low pressure, 5–10 min
RO preservation, idle more than a few days1–1.5 % sodium metabisulphite
CIP solutionsalkaline: NaOH to pH 11–12 · acid: citric, to the maker's strength and pH · both 25–35 °C

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Vacuum slow to build, settles lowEjector pump and overboard pressuresAir leak at a gland, glass, drain plug, or vacuum breaker; nozzle worn; back pressureSoap-test; overboard valve to the stop; renew nozzle
Vacuum fine, output low, shell coolHT valves and bypass; engine loadNot enough heatSet the bypass; accept the output; steam supplement
Vacuum fine, output low, HT ΔT smallDosing tank; output trendHeating surface scaledDescale
Output down only in warm waterCondenser SW outletCondenser limitNothing; log it
Brine level risingOverboard back pressure; feed orificeBack pressure; ejector worn; orifice erodedClear the overboard path; nozzle; orifice
Salinity high at start, not clear in 15 minBrine level; demisterDemister flooded or torn; condenser plate leakLower the level; inspect; pressure-test the condenser
Salinometer at 0.0 for daysProbe in a cup of seawaterDead cell or broken leadReplace; distillate tank chlorides meanwhile
Distillate pump running, tray full, no outputVent; glandAir-bound; air at the suction jointVent; repack
JW head tank top-ups risingSecure HT to the evaporator for a dayHeating plate or gasket leaking JW to the seawater sideHeat Exchangers — find the plate
RO permeate down, pressure and ΔP up, conductivity sameCartridge ΔP; feed temperatureMembranes foulingCIP
RO permeate down, pressure downCartridges; LP pump; HP pumpPre-filters blocked; feed starved; pump valves wornCartridges; overhaul the pump
RO conductivity up, permeate sameRecent element changeO-ring, interconnector, or brine seal; damaged elementProbe each vessel; reseat
RO conductivity and permeate both creeping up for monthsFeed chlorine historyMembranes oxidizedReplace elements; fix dechlorination

Draft: this page is drawn from the book manuscript and is still being checked.