A freshwater generator boils seawater under vacuum with jacket water heat and condenses the vapor; a reverse osmosis unit pushes seawater through a membrane that holds the salt back. Both are judged by output and by the salt that gets through, and both die of scale or fouling on a surface you can't see.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Time to full vacuum after the ejector pump starts | 10–15 min; longer is an air leak |
| Shell temperature vs vacuum | 44–46 °C at about 90 % — they move together |
| Feed-to-distillate ratio | about 2–3:1 |
| Brine concentration | about 1.5–2× seawater |
| Brine level in the shell glass | Maker's mark; above is carryover, below is bare heating surface |
| Ejector back pressure, overboard line | below about 0.6 bar |
| Rated output falls off above seawater | about 30–32 °C |
| Anti-scale dosing, 20–30 t/day unit | roughly 0.5–1 L/day by the maker's chart |
| RO recovery (permeate ÷ feed) | 25–40 % |
| RO cartridge pre-filter | 5 µm; change at 0.7–1.0 bar ΔP or 2× clean |
| RO feed temperature | 5–40 °C; permeate changes about 3 % per °C |
| Free chlorine at the membranes | 0 — polyamide membranes don't survive it |
| RO clean at | normalized permeate down 10–15 %, or feed-to-brine ΔP up 15 % |
| RO flush on shutdown | permeate, low pressure, 5–10 min |
| RO preservation, idle more than a few days | 1–1.5 % sodium metabisulphite |
| CIP solutions | alkaline: NaOH to pH 11–12 · acid: citric, to the maker's strength and pH · both 25–35 °C |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Vacuum slow to build, settles low | Ejector pump and overboard pressures | Air leak at a gland, glass, drain plug, or vacuum breaker; nozzle worn; back pressure | Soap-test; overboard valve to the stop; renew nozzle |
| Vacuum fine, output low, shell cool | HT valves and bypass; engine load | Not enough heat | Set the bypass; accept the output; steam supplement |
| Vacuum fine, output low, HT ΔT small | Dosing tank; output trend | Heating surface scaled | Descale |
| Output down only in warm water | Condenser SW outlet | Condenser limit | Nothing; log it |
| Brine level rising | Overboard back pressure; feed orifice | Back pressure; ejector worn; orifice eroded | Clear the overboard path; nozzle; orifice |
| Salinity high at start, not clear in 15 min | Brine level; demister | Demister flooded or torn; condenser plate leak | Lower the level; inspect; pressure-test the condenser |
| Salinometer at 0.0 for days | Probe in a cup of seawater | Dead cell or broken lead | Replace; distillate tank chlorides meanwhile |
| Distillate pump running, tray full, no output | Vent; gland | Air-bound; air at the suction joint | Vent; repack |
| JW head tank top-ups rising | Secure HT to the evaporator for a day | Heating plate or gasket leaking JW to the seawater side | Heat Exchangers — find the plate |
| RO permeate down, pressure and ΔP up, conductivity same | Cartridge ΔP; feed temperature | Membranes fouling | CIP |
| RO permeate down, pressure down | Cartridges; LP pump; HP pump | Pre-filters blocked; feed starved; pump valves worn | Cartridges; overhaul the pump |
| RO conductivity up, permeate same | Recent element change | O-ring, interconnector, or brine seal; damaged element | Probe each vessel; reseat |
| RO conductivity and permeate both creeping up for months | Feed chlorine history | Membranes oxidized | Replace elements; fix dechlorination |
Draft: this page is drawn from the book manuscript and is still being checked.