Filters and strainers stop dirt before it reaches a pump, an injector, a bearing, or a cooler. Every one of them clogs, bypasses, or tears, and the differential pressure (ΔP) across it tells you which.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Seawater basket strainer ΔP — clean / change over | < 0.1 / 0.3 bar |
| Pump suction strainer ΔP — clean / change over | < 0.1 / 0.3 bar |
| Seawater basket perforation | 3–6 mm |
| Fuel and LO suction strainer mesh | 0.5–1 mm |
| Main engine fuel autofilter rating | 10–34 µm |
| Autofilter backflush | on ΔP rise or timer, typically about hourly |
| Knife-edge fuel strainer change-out | ~500 running hours, or on ΔP |
| Cartridge element ΔP indicator | pops at the maker's figure; change, don't clean |
| ΔP reading of zero | not "clean" — suspect a torn element, open bypass, or missing basket |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| ΔP rising faster than usual | Fluid source; recent changes | Fuel changeover loosening sludge; purifier not separating; dirty tank stripped; shallow or dirty water | Change over and clean; then find the source |
| ΔP near zero, was normal | Basket in place; element whole; bypass | Torn mesh or element; basket missing or seated wrong; internal bypass open; gauge isolation shut | Isolate and open; renew the element; check the gauge cocks |
| Pump loses suction during changeover | Standby side vented? | Standby side empty or air-bound; changeover turned too fast | Go back to the old side; fill and vent standby; change over slowly |
| Housing still reads pressure when isolated | Inlet, outlet, and changeover position | Inlet valve leaking by; changeover not fully shifted; return valve passing | Shut a third valve — the quick-closing valve — bleed down; don't open |
| Generator low fuel pressure after a fuel changeover | Knife-edge strainer ΔP | Strainer choked with loosened sludge; new strainer not yet broken in | Turn and drain strainers; crank more often for the next days |
| Autofilter counter not moving | Indicator, motor, cams, air supply | Stuck between cams; control failed; flush valve seized | Flush manually about every hour; bypass filter in; repair |
| Autofilter flushing constantly | ΔP signal; elements | Elements blinded; fuel wet or incompatible; ΔP switch faulty | Bypass in; clean elements; check purifier and fuel |
| Knife-edge handle stiff or won't turn | When last turned | Sludge set hard on the stack; blades bent | Work it gently both ways; isolate and pull the stack |
| Fuel still running from drain after draining | Drain valve | Spring hasn't reseated | Twist the valve until it seats; renew if it won't |
| Fluid downstream dirty with normal ΔP | Element type; bypass | Wrong mesh; internal bypass stuck open; element seal or O-ring missing | Open and check fit and seals |
| Cartridge housing leaks after change | O-ring and seat | O-ring pinched, missing, or wrong size; dinged cover seat | Refit with the right O-ring; temporary PTFE wrap on a damaged seat |
| Sludge or bilge pump starving, strainer clean | Mesh size; magnets | Mesh too fine for the fluid; magnets loaded and choking flow | Fit the right basket; clean magnets |
| ECR air conditioning trips on head pressure | LT cooler strainer ΔP | LT or SW cooler strainer loading | Change over coolers; clean the strainer now |
| New element won't fit | Spare against the old | Wrong part; flange holes or dimensions off | Check spares fit before you need them |