Jacket water holds each liner, head, and exhaust valve seat in a narrow temperature band; oil holds each bearing on its film, cools each piston crown, and on a crosshead engine is metered onto each liner. The plants behind them are in Seawater and Central Cooling and Lube Oil Plant; this chapter starts where the pipes reach the engine.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Jacket (HT) outlet | 80–90 °C, at set point at every load |
| Jacket ΔT at full load / unit to unit | 5–12 °C / within about 5 °C |
| Jacket temperature before a start | Maker's minimum, commonly 50–60 °C; many ships hold 80–85 °C in port |
| System LO inlet pressure | 2–4.5 bar; medium-speed 4–6 bar |
| System LO inlet temperature | 40–50 °C; medium-speed 55–70 °C |
| Crosshead oil, booster pump fitted | 10–16 bar |
| Piston cooling oil outlet, each unit | 50–70 °C; units within about 10 °C |
| Cylinder oil feed rate | 0.6–1.0 g/kWh; older mechanical systems up to 1.5; raised for running-in |
| Scrape-down iron | Commonly under about 200 ppm, steady per unit |
| Scrape-down residual BN | Inside the oil supplier's band — near zero and near fresh are both wrong |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Jacket outlet low at load | Three-way valve against a local thermometer; FWG | Valve stuck to cooling; sensor high; FWG taking more than a low load gives | Hand-control; cut the FWG; open heater steam |
| One unit's outlet high or hunting after work | Its vent cock | Air in the cover or valve housing — until proven otherwise | Vent at load, and again hot |
| Expansion tank losing; one unit's scavenge drain wet | Nitrite test on the drain | Jacket water past the liner seals or a cracked liner | Plan the unit; turn over with cocks open before every start |
| Piston cooling outlet high or no-flow, one unit | Flow at its glass; its crosshead temperature | Telescopic pipe or link gland; blocked bore; blow-by heating the crown | Treat no-flow as real until the glass shows oil; reduce load; inspect the supply |
| LO pressure falling, temperature rising | LO cooler four temperatures; LT supply | Cooler fouled; LT warm or short; three-way valve | Restore cooling; pressure follows |
| LO pressure falling, temperature steady | Sump level; filter ΔP | Low level; filter loading; pump worn or relief passing; gland leaking inside | Standby pump; static filter in; find the leak |
| Crosshead pressure low, main LO normal | Booster, strainer, standby | Booster worn; relief passing; strainer blocked | Standby booster; emergency supply at reduced load |
| Lubricator alarm, one unit | Feedback lamp or sight glasses; line at the quill | Solenoid or pump unit; air; blocked line or quill | Change and prime; reduce load until it feeds — a dry liner scuffs in hours |
| Heavy black scavenge drains, consumption normal | Which units; exhaust spread | Blow-by; lubricator timing; poor combustion; stuffing box passing up | Ring inspection; card the unit |
| Four-stroke sump rising, oil thin | Flash point; viscosity; water test | Fuel from an injector, pump, or HP pipe; water from cooler or jacket | Find the leak; change the oil if past limits |
Draft: this page is drawn from the book manuscript and is still being checked.