Part I · The Plants

Compressed Air

Compressed air starts the engines and operates every pneumatic valve, actuator, and instrument on the ship. Two or three compressors keep a set of receivers full; everything else draws from them.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Starting air receivers25–30 bar
Service / control air header7–10 bar
Instrument air after regulator4–6 bar
Interstage (between 1st and 2nd stage)3–5 bar
Air temp after aftercoolercooling water temp + 10–15 °C
Compressor lube oil pressure2–4 bar
Compressor sump levelmaker's mark — not above it
Dew point — refrigerated / desiccant dryer+3 °C / −40 °C
Compressor cycling at seaa few starts per hour

The tour

The plant, stop by stop, as the book walks it.

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Compressor runs constantly, pressure holdingClose receiver outlet; does pressure still fall?Leak downstream; deck air open; auto drain stuck openIsolate by section; walk and listen
Compressor runs constantly, pressure fallingInterstage pressureWorn valves or rings; inlet filter; fouled unloaderOverhaul valves
Slow recovery between startsCompressors runningOne not auto-starting; capacity loss; leakStart all; check auto; overhaul after
Interstage relief liftingLast valve job2nd-stage valve wrong way round or leaking; scored cylinderCheck orientation; then open the cylinder
Discharge temp or pressure highCoolers; cooling waterFouled coolers; low CW flow; leaking valveClean coolers; restore CW
Compressor tripping on high ampsTurn it by handSeizing piston; valve fault; lubricator not feedingOpen and inspect before blaming the motor
Glitter in sump, knock, metal in unloaderStop itBearing or piston wear; broken valve; loose hardwareOpen and inspect before running again
Water at receiver drains or usersAuto drains, dryerDrain stuck closed; dryer failedManual drain; fix drain; standby dryer
Oil in receivers or linesSump level and oil gradeWorn rings; overfilled; wrong oilCorrect level and grade; ring overhaul
Control air pressure fallingRegulator; dryer ΔPRegulator fault; elements blocked; leakRebuild; change elements; find leak
Remote valves sticking, control valves huntingDew point; low-point drainsWet or dirty control airFix dryer; drain; jog valves; use overrides
Engine won't turn on airReceiver pressure; turning gear interlockLow pressure; main start valve stuck; distributorClear interlock; check main and pilot valves
Generator cranks slowly, or starts locally but not remotelyCranking speed; start air regulatorWorn air-start motor; regulator out of adjustmentRebuild starter; reset regulator
One start-line branch hotIR gun on all branchesCylinder air start valve leakingChange valve first opportunity
Emergency compressor won't start or fills slowlyPower or battery; timed fillDead battery; seized; worn valvesFix now — not when you need it

Scenarios

Work out what you’d do, then open it.

air leaks with one compressor down

One start-air compressor is out with a scored cylinder. The other is worn and runs almost continuously; stopped, the receivers lose 2–4 bar in 10 minutes. The main engine's emergency stop works on start air. What do you prioritize?

The leaks — they are killing the last compressor. Isolate sections with the compressor stopped: deck and service air, control air, then the start lines. Tell the engineer in charge the main engine is one compressor failure from losing start air, emergency-stop air, and the ability to maneuver. Repairing the scored unit becomes the top job.

maneuvering

Arriving in port with a reversible main engine. After six starts, receiver pressure is at 18 bar and falling faster than the compressors recover. The pilot wants another astern. What do you do?

Get every compressor running — the third in manual rather than waiting for its auto cut-in. Tell the bridge now, in starts remaining, not "we're getting low." Below minimum starting pressure the next start fails at the worst moment. Afterward, find out why the compressors were behind — check the interstage log.

seized after overhaul

A start-air compressor seizes a piston about 50 running hours after an overhaul. What do you look at besides the piston?

Oil delivery to that piston. A lubricator not feeding one cylinder, unprimed lines, or sealant in an oil passage all end the same way. Hone or replace the cylinder, fit a new piston and new valves on that stage, replace the lubricator if it isn't delivering, and prime every line. Then check how the other compressors were assembled.

blackout recovery

Blackout at sea; the standby generator recovers the bus. What in compressed air doesn't come back by itself, and what follows if you forget it?

On many ships the working air compressor needs a manual reset. Forget it and control and start air bleed down over the next hour: positioners drift, then the main engine loses start and safety air. Reset it once the bus is stable. If no generator recovers the bus: emergency generator, emergency compressor, emergency receiver, then one generator — only a set whose controls are fed from the emergency board.

Dependencies

Needs
  • Electrical — compressors, refrigerated dryer, auto drains; some compressors need a reset after a blackout
  • Emergency switchboard or an independent diesel — emergency compressor
  • LT cooling water — compressor jackets and coolers
  • The correct compressor oil — every unit consumes it
Feeds
  • Main engine and generator starting
  • Main engine safety and emergency-stop air; exhaust valve air springs where fitted
  • Every pneumatic valve, actuator, positioner, and controller, including remote tank valves
  • Quick-closing valve release where air-operated
  • Whistle; service and deck air; air diaphragm pumps; sewage ejectors, OWS, soot blowers where fitted

Draft: this page is drawn from the book manuscript and is still being checked.