Part II · The Equipment · Family 3 · Heat It or Cool It · Stage 2 · First month

Boilers and Burners

A boiler turns feedwater into steam by burning oil in a furnace or by catching heat from engine exhaust. The burner, the water level, and the fire side are what fail; the plant around them is in Steam.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Flue gas O₂ / CO₂, oil firing at high fire3–5 % / 12–14 %
SmokeLight haze at most; Bacharach 1–2
Stack temperature, fire-tube aux boilersteam temperature + 50–100 °C
Clean the fire side atstack 30–50 °C above clean baseline at the same firing rate
Fuel viscosity at the atomizer — pressure jet / rotary cup12–18 cSt / up to about 25 cSt
Atomizing steam or air, assisted burners2–5 bar
Turndown — simplex jet / spill-return or assisted / rotary cup~2:1 / up to ~10:1 / ~8–10:1
Flame signalSteady, well above the maker's minimum
EGB circulation ratio (water pumped ÷ steam made)3–8
EGB gas-side ΔP, blow or wash atabout 1.5× clean baseline
Casing by hand or IR gunUnder 60–70 °C
Thermal oil outlet180–300 °C by system

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Lockout in pre-purgeAir switch; damper limit switchesFan belt or motor; linkage slipped; switch tube blockedProve the fan; reset the linkage
Lockout at trial, no flame seenElectrodes; tipCracked insulator or wrong gap; tip coked; fuel cold; air in the lineClean and gap; change the tip; bleed
Lockout at trial, flame was thereScanner lens; aimDirty lens; mis-aimed after work; scanner failingClean; re-aim; replace
Flame failure in runFuel pressure and temperature trendPressure dips — changeover, filters, pump wear; water in fuelChange filters; drain the settler; hold viscosity
Black smokeFuel temperature; damperCold fuel; too little air; worn tip or dirty cupFuel temperature first, then air, then atomizer
Clear stack, high O₂Linkage; fuel pressureToo much air; fuel pressure lowReset the ratio; check the regulator
Pulsating or rumbling flameAtomizing and fuel pressureUnstable atomization; air leaks into the furnace; damper huntingSteady the pressures; seal the leaks
Flame on the rear wallQuarl; tip part numberWorn quarl; cold fuel; wrong tipRight tip; fuel to spec; renew quarl
Stack temperature up, same firing rateFire-side portsSoot; water-side scale; baffle burnt outClean; test the water; inspect baffles
Casing hot spot, blistered paintWall behind it through the portRefractory fallen; insulation displaced; gas past a doorFire-side opening soon
Level cycling wide, pump short-cyclingProbe column or float chamberSludge on probes or float; band too narrow; swellBlow down the column; widen the band
Safety valve feathering below setWorking pressure vs setDirt on the seat; working pressure too close; spring relaxedLift on the easing gear; persists — survey job
EGB ΔP up, blowing logged dailyHeader drain at the next blowWet steam; nozzles blocked; soot baked on during low circulationDrain to dry steam; wash at the next stop
Thermal oil outlet climbing, flow lowPump; strainer; expansion tankPump failing; strainer blocking; vapor in the coilBurner off until flow is proven