The bilge system collects everything that leaks, drips, and drains in the machinery spaces and gets it off the ship without putting oil in the sea. Water goes overboard through the separator at 15 ppm or less; oil and sludge are burned or landed ashore, and every movement goes in the Oil Record Book.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Bilge wells | dry to a few centimeters; well below alarm before UMS |
| Oily bilge pump suction on ER wells | about −0.5 bar |
| OWS throughput | 0.25–5 m³/h by ship size |
| OWS supply pressure | 1–3 bar |
| Bilge holding tank, lowest level to feed the OWS | about 1 m, or maker's mark |
| Oil content overboard | 15 ppm limit; 0–5 ppm on a healthy unit |
| Monitor calibration | maker's interval, certificate on board; never over 5 years |
| Sludge produced, HFO ship | 1–2 % of fuel burned |
| Oily bilge and sludge tanks, pumping ashore | 40–50 °C |
| Lowest practical sounding, heated tank to shore | 20–30 cm |
| Slops discharge rate, piston or diaphragm pump | 8–15 m³/h; a full discharge is a working day |
| Incinerator sludge service tank | 80–90 °C |
| Incinerator combustion chamber | 850–1,100 °C |
The plant, stop by stop, as the book walks it.
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Same well alarms every watch | Rate of rise; what drips above it | Gland leak; cooler drain; condensate; pipe weep | Trace and stop it — it is filling the holding tank and the ORB |
| All wells rising together | Tank top; SW pipes; overboard and drain valves | SW pipe failure; cooler leak; tank overflow | Find it now — this is flooding, not a bilge job |
| Oily bilge pump will not prime | Suction gauge; suction valve bonnets; strainer | Rags; air leak; pump-side valve leaking by | Prime with water; open bonnets; close the tank-side valve |
| OWS ppm high from start | Sample in a glass; smell for soap | Emulsion from detergent; coalescer saturated; feed too fast | Stop; this batch goes ashore; keep soap out of the bilge |
| OWS ppm fine then climbs mid-run | Holding tank level and oil layer | Oil layer at the suction; tank below about 1 m | Stop; skim oil to sludge tank; change element |
| OWS reads 0 ppm on everything | Sample flow through the cell; flush valve | Sample line blocked; flush water passing; cell fault | No discharge; restore sample flow; glass sample |
| Sludge tank rising faster than fuel burn | Bottom drain; purifier desludge interval; coil | Water in sludge; coil leaking; over-frequent desludge | Drain water; check purifier timer; test coil |
| Sludge pump screams mid-discharge | Sounding; how many tanks are open | Tank at sediment; two heated tanks open | Stop; change tank; one heated tank at a time |
| Sludge in the bilge pump containment | Crossover between the pumps | Sludge tank head pushing through the crossover | Close the crossover; clean up; repack |
| Sludge pump motor running, no flow | Belts; pump turning | Jammed valve seat or debris; seized pump | Stop; open the pump; do not run on another belt |
| Incinerator flame failure mid-burn | Service tank water; nozzle; atomizing air | Wet sludge; blocked nozzle; low air; dirty scanner | Drain and reheat service tank; clean nozzle and scanner; restart on pilot |
| ORB totals do not match soundings | Sound every tank; last receipts | Arithmetic; unlogged transfer; wrong tank table | Reconcile today; code I remark explaining the correction |
Work out what you’d do, then open it.
The separator alarms at 18 ppm as soon as the three-way valve goes to overboard, every run, for a week. The chief wants the holding tank down before port. What do you do, and what do you not do?
You do not touch the three-way valve, the monitor settings, or the sample line, and nobody runs a hose. Find out whether the water or the monitor is the problem: a glass sample from the clean outlet against the light, and a monitor zero check on fresh water. A milky sample means an emulsified bilge — somebody has been using detergent — and no separator will fix it; the batch is landed in port and the ORB says so. A clear sample with the monitor still at 18 means a fouled or drifted cell: clean it per maker, re-zero, and if it still reads high it is a service call and no discharge until then. Either way the ORB gets an entry today — code F for the monitor, or code I noting the emulsion and the plan to land it.
The incinerator has a cracked refractory and is out of service. The sludge tank is at 90 %. Three days to port. What stops, and in what order?
Nothing stops yet, but the purifiers keep desludging into the tank, the separator sends oil to it, and the drain tanks drain into it. When it is full you are choosing between stopping the purifiers — no clean fuel, engine stops within hours — and sludge going somewhere unplanned. Sound it and find out how much is water; drain the water off the bottom through the fitted drain, log it, and heat the tank — that often buys a third of the tank back. Check the purifier desludge interval; an over-eager timer is a common reason for 90 %. Book a reception facility now, through the agent, with the quantity. What you never do is move sludge into the bilge holding tank.
Slops to a barge. Two hours in, the sludge pump starts screaming and its discharge pressure jumps around. Next to it, the bilge pump's containment is filling with sludge from its packing. What happened, and what should the pre-start check have caught?
Two separate faults with one cause: too much open. The sludge tank's head is pushing through an open crossover into the idle bilge pump, and if a second heated tank is open, it has pushed the suction above zero. Or the tank is simply down to its sediment. Stop the pump, close the crossover, close every tank suction but one — at the tank, not just at the pump — and sound. Above 30 cm, restart on that one tank; below, move on. The pre-start check is the written lineup: one tank, crossover shut, emergency stop tested, and every valve to the receiver confirmed open. A reciprocating pump started against a shut valve on the barge tears its piston off the rod.