Part I · The Plants

Bilge, Oily Water Separator, Sludge, and Incinerator

The bilge system collects everything that leaks, drips, and drains in the machinery spaces and gets it off the ship without putting oil in the sea. Water goes overboard through the separator at 15 ppm or less; oil and sludge are burned or landed ashore, and every movement goes in the Oil Record Book.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Bilge wellsdry to a few centimeters; well below alarm before UMS
Oily bilge pump suction on ER wellsabout −0.5 bar
OWS throughput0.25–5 m³/h by ship size
OWS supply pressure1–3 bar
Bilge holding tank, lowest level to feed the OWSabout 1 m, or maker's mark
Oil content overboard15 ppm limit; 0–5 ppm on a healthy unit
Monitor calibrationmaker's interval, certificate on board; never over 5 years
Sludge produced, HFO ship1–2 % of fuel burned
Oily bilge and sludge tanks, pumping ashore40–50 °C
Lowest practical sounding, heated tank to shore20–30 cm
Slops discharge rate, piston or diaphragm pump8–15 m³/h; a full discharge is a working day
Incinerator sludge service tank80–90 °C
Incinerator combustion chamber850–1,100 °C

The tour

The plant, stop by stop, as the book walks it.

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Same well alarms every watchRate of rise; what drips above itGland leak; cooler drain; condensate; pipe weepTrace and stop it — it is filling the holding tank and the ORB
All wells rising togetherTank top; SW pipes; overboard and drain valvesSW pipe failure; cooler leak; tank overflowFind it now — this is flooding, not a bilge job
Oily bilge pump will not primeSuction gauge; suction valve bonnets; strainerRags; air leak; pump-side valve leaking byPrime with water; open bonnets; close the tank-side valve
OWS ppm high from startSample in a glass; smell for soapEmulsion from detergent; coalescer saturated; feed too fastStop; this batch goes ashore; keep soap out of the bilge
OWS ppm fine then climbs mid-runHolding tank level and oil layerOil layer at the suction; tank below about 1 mStop; skim oil to sludge tank; change element
OWS reads 0 ppm on everythingSample flow through the cell; flush valveSample line blocked; flush water passing; cell faultNo discharge; restore sample flow; glass sample
Sludge tank rising faster than fuel burnBottom drain; purifier desludge interval; coilWater in sludge; coil leaking; over-frequent desludgeDrain water; check purifier timer; test coil
Sludge pump screams mid-dischargeSounding; how many tanks are openTank at sediment; two heated tanks openStop; change tank; one heated tank at a time
Sludge in the bilge pump containmentCrossover between the pumpsSludge tank head pushing through the crossoverClose the crossover; clean up; repack
Sludge pump motor running, no flowBelts; pump turningJammed valve seat or debris; seized pumpStop; open the pump; do not run on another belt
Incinerator flame failure mid-burnService tank water; nozzle; atomizing airWet sludge; blocked nozzle; low air; dirty scannerDrain and reheat service tank; clean nozzle and scanner; restart on pilot
ORB totals do not match soundingsSound every tank; last receiptsArithmetic; unlogged transfer; wrong tank tableReconcile today; code I remark explaining the correction

Scenarios

Work out what you’d do, then open it.

18 ppm

The separator alarms at 18 ppm as soon as the three-way valve goes to overboard, every run, for a week. The engineer in charge wants the holding tank down before port. What do you do, and what do you not do?

You do not touch the three-way valve, the monitor settings, or the sample line, and nobody runs a hose. Find out whether the water or the monitor is the problem: a glass sample from the clean outlet against the light, and a monitor zero check on fresh water. A milky sample means an emulsified bilge — somebody has been using detergent — and no separator will fix it; the batch is landed in port and the ORB says so. A clear sample with the monitor still at 18 means a fouled or drifted cell: clean it per maker, re-zero, and if it still reads high it is a service call and no discharge until then. Either way the ORB gets an entry today — code F for the monitor, or code I noting the emulsion and the plan to land it.

sludge tank full, port in three days

The incinerator has a cracked refractory and is out of service. The sludge tank is at 90 %. Three days to port. What stops, and in what order?

Nothing stops yet, but the purifiers keep desludging into the tank, the separator sends oil to it, and the drain tanks drain into it. When it is full you are choosing between stopping the purifiers — no clean fuel, engine stops within hours — and sludge going somewhere unplanned. Sound it and find out how much is water; drain the water off the bottom through the fitted drain, log it, and heat the tank — that often buys a third of the tank back. Check the purifier desludge interval; an over-eager timer is a common reason for 90 %. Book a reception facility now, through the agent, with the quantity. What you never do is move sludge into the bilge holding tank.

screaming sludge pump

Slops to a barge. Two hours in, the sludge pump starts screaming and its discharge pressure jumps around. Next to it, the bilge pump's containment is filling with sludge from its packing. What happened, and what should the pre-start check have caught?

Two separate faults with one cause: too much open. The sludge tank's head is pushing through an open crossover into the idle bilge pump, and if a second heated tank is open, it has pushed the suction above zero. Or the tank is simply down to its sediment. Stop the pump, close the crossover, close every tank suction but one — at the tank, not just at the pump — and sound. Above 30 cm, restart on that one tank; below, move on. The pre-start check is the written lineup: one tank, crossover shut, emergency stop tested, and every valve to the receiver confirmed open. A reciprocating pump started against a shut valve on the barge tears its piston off the rod.

Dependencies

Needs
  • Electrical — bilge pumps, separator feed pump, monitor, incinerator fans and burner
  • Compressed air — separator three-way valve and oil valve on most units, incinerator atomizing air, the diaphragm backup pump
  • Steam or electric heating — sludge and oily bilge tanks, incinerator service tank, separator heater
  • Fuel — incinerator pilot burner (MDO/MGO)
  • Fire main — bilge eductor driving water
  • Main seawater cooling pump — emergency bilge suction
Feeds
  • A dry tank top — motors, cable trays, and the stern tube forward seal all live there
  • The fuel and lube purifiers — they stop when the sludge tank is full
  • The ship's clearance to sail — ORB, garbage record, separator and monitor certificates