Part II · The Equipment · Family 2 · Clean It · Stage 3 · First hitch

Ballast Water Treatment Systems

A ballast water treatment system kills or removes the organisms in ballast water so the ship doesn't carry live ones from port to port. It sits between the ballast pumps and the manifold, treats on uptake and often again on discharge, and logs every operation and fault for port state control. The ship-side line-up and the mate's part are in Ballast, Stop 7 and Routines.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Filter ΔP, clean / backflush / alarm0.1–0.2 / 0.3–0.5 / 0.7–1.0 bar
Filter inlet pressure for a good backflush1.5–2.5 bar minimum
Treatment flow windowabout 50–100 % of rated; outside it, alarm or stop
UV lamp warm-up before flow1–5 min; a hot lamp won't restrike until cool
UV lamp life3,000–12,000 h, by lamp type
UV reactor temperature alarm45–65 °C
Electrochlorination minimum salinityby approval, often 10–20 PSU
Holding time after electrochlorination24 h to 5 days, by approval
Hydrogen at the degas ventbelow 1 % v/v with the blower running
Electrical loadtens to hundreds of kW — second generator first
Data log kept on the unit24 months or more

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Constant backflush, ΔP never returns to cleanInlet pressureInlet below backflush minimum; silt caked on the screenThrottle downstream of the unit to raise inlet pressure; open and clean
ΔP high, backflush valve shows open, nothing coming outValve locally; backflush lineActuator stuck; line blocked; nozzle arm not turningOperate locally; clear the line; check the drive
Filter never backflushes, ΔP flatScreenScreen torn or seal bypassing; ΔP sensing lines blockedOpen and inspect against a light; blow through the lines
Lamps won't strikeWhich positionsAged lamp; lamp power supply; connector; wet sleeveSwap the lamp — if the fault stays with the position, it's the supply
UV intensity low from the start, water clearCIP log; lamp hoursFouled sleeves or sensor window; aged lampsCIP; clean the window; change lamps on hours
Reactor temperature high, lamps trippedFlow at the tripFlow lost with lamps litRestore flow before relighting; find why the interlock didn't act
Flow out of range, system stopsFlow control valve; pumpFilter blinding; valve stuck; pump cavitating on a low tank; meter faultClear the cause; reset once
TRO at injection low, rectifier at maximumSalinity; cell voltageFresh or cold water; scaled cells; side-stream flow lowLow-salinity mode per plan; acid clean; side-stream strainer
Cell voltage climbing at constant currentLast acid cleanScale; corroding plate or connectionAcid clean; renew cells if it won't come back
Hydrogen alarmBlower; vent; degas tank levelBlower failed; vent or flap blocked; tank floodingRectifier off; restore ventilation first
Discharge TRO high, dosing pump runningNeutralizer level and ageTank empty or weak; pump lost prime; sensor fouledStop the discharge; renew; bleed; clean the sensor
Bypass alarm, nobody at the bypassValve switch; sealSwitch or wiring failed; seal brokenProve the valve shut; log the alarm and the finding

Draft: this page is drawn from the book manuscript and is still being checked.