A ballast water treatment system kills or removes the organisms in ballast water so the ship doesn't carry live ones from port to port. It sits between the ballast pumps and the manifold, treats on uptake and often again on discharge, and logs every operation and fault for port state control. The ship-side line-up and the deck side are in Ballast, Stop 7 and Routines.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Filter ΔP, clean / backflush / alarm | 0.1–0.2 / 0.3–0.5 / 0.7–1.0 bar |
| Filter inlet pressure for a good backflush | 1.5–2.5 bar minimum |
| Treatment flow window | about 50–100 % of rated; outside it, alarm or stop |
| UV lamp warm-up before flow | 1–5 min; a hot lamp won't restrike until cool |
| UV lamp life | 3,000–12,000 h, by lamp type |
| UV reactor temperature alarm | 45–65 °C |
| Electrochlorination minimum salinity | by approval, often 10–20 PSU |
| Holding time after electrochlorination | 24 h to 5 days, by approval |
| Hydrogen at the degas vent | below 1 % v/v with the blower running |
| Electrical load | tens to hundreds of kW — second generator first |
| Data log kept on the unit | 24 months or more |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Constant backflush, ΔP never returns to clean | Inlet pressure | Inlet below backflush minimum; silt caked on the screen | Throttle downstream of the unit to raise inlet pressure; open and clean |
| ΔP high, backflush valve shows open, nothing coming out | Valve locally; backflush line | Actuator stuck; line blocked; nozzle arm not turning | Operate locally; clear the line; check the drive |
| Filter never backflushes, ΔP flat | Screen | Screen torn or seal bypassing; ΔP sensing lines blocked | Open and inspect against a light; blow through the lines |
| Lamps won't strike | Which positions | Aged lamp; lamp power supply; connector; wet sleeve | Swap the lamp — if the fault stays with the position, it's the supply |
| UV intensity low from the start, water clear | CIP log; lamp hours | Fouled sleeves or sensor window; aged lamps | CIP; clean the window; change lamps on hours |
| Reactor temperature high, lamps tripped | Flow at the trip | Flow lost with lamps lit | Restore flow before relighting; find why the interlock didn't act |
| Flow out of range, system stops | Flow control valve; pump | Filter blinding; valve stuck; pump cavitating on a low tank; meter fault | Clear the cause; reset once |
| TRO at injection low, rectifier at maximum | Salinity; cell voltage | Fresh or cold water; scaled cells; side-stream flow low | Low-salinity mode per plan; acid clean; side-stream strainer |
| Cell voltage climbing at constant current | Last acid clean | Scale; corroding plate or connection | Acid clean; renew cells if it won't come back |
| Hydrogen alarm | Blower; vent; degas tank level | Blower failed; vent or flap blocked; tank flooding | Rectifier off; restore ventilation first |
| Discharge TRO high, dosing pump running | Neutralizer level and age | Tank empty or weak; pump lost prime; sensor fouled | Stop the discharge; renew; bleed; clean the sensor |
| Bypass alarm, nobody at the bypass | Valve switch; seal | Switch or wiring failed; seal broken | Prove the valve shut; log the alarm and the finding |