The ballast system moves seawater into and out of the double bottom, wing, peak, and topside tanks so the ship floats at the draft, trim, and stability the mate needs. The treatment system kills what lives in that water on the way in or out, and the ballast record book proves it.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Ballast pump capacity | 200–1,500 m³/h each, two pumps |
| Pump discharge pressure | 2–3.5 bar |
| Pump suction | 0 to −0.4 bar from a low tank; near zero from the sea |
| Extra discharge pressure through the treatment plant | 0.5–1 bar |
| Eductor driving pressure | 6–9 bar |
| Remote valve hydraulic system | 100–150 bar |
| Pneumatic valve air | 6–8 bar |
| Valve travel, open to shut | 30–90 s |
| Remote tank gauge dead band near the bottom | several m³; log what each reads empty |
| Submerged pump shaft seal air test after repair | 3 bar, held 1 h |
| BWTS filter screen | 20–50 µm |
| Filter ΔP backflush trigger | 0.3–0.5 bar |
| UV intensity or transmittance | above maker's minimum, by alarm |
| TRO at injection (electrochlorination) | 5–10 mg/L as Cl₂ |
| TRO at discharge after neutralization | below 0.1–0.2 mg/L |
| D-2 discharge standard | <10 viable organisms/m³ at ≥50 µm; <10/mL at 10–50 µm |
| D-1 exchange, where still allowed | 95 % volumetric; 200 nm from land, 200 m depth |
The plant, stop by stop, as the book walks it.
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Valve lamp says open, tank level not changing | Local position indicator; feel the pipe | Actuator stalled; limit switch false; hydraulic supply lost | Operate locally; correct the limit switch after |
| Valve lamp says shut, tank level changing | Local indicator; neighboring valves | Valve stopped short; seat torn; crossover open | Shut locally; check the whole line-up for passing valves |
| Valve slow, stops midway, or will not move | Hydraulic pressure or control air; local indicator | HPU pump worn; hose leak; air in the system; wet control air | Jog it from the panel; operate locally; find the leak |
| Pump noisy, discharge pressure swinging | Tank level; strainer; suction valve | Cavitation on a low tank; choked strainer | Stop; eductor for the rest; clean strainer |
| Pump quiet, no discharge, low amps | Priming unit; suction line-up | Air in casing; priming failed; suction open to an empty tank | Prime; correct line-up |
| Priming unit runs non-stop | Suction side joints; sounding pipe caps | Air leak on suction | Soap test flanges; close the cap |
| HPU pumps short-cycling | Cycle time against the logged baseline | Low accumulator precharge; internal leak | Recharge the accumulator; find the leak |
| Sheen at the overboard after a pump seal repair | Pump just returned to service? | Residual oil from the repair; seal not tight | Stop; contain; re-test the seal |
| Water from a vent head on deck | Tank level; which valve is open | Tank overfilled; valve passing; wrong tank | Shut the valve; tell the mate; sound the tank |
| Tank will not drain below a level | Trim; eductor; suction well | Trim; eductor not lifting; mud | Eductor; adjust trim with the mate; sound by hand |
| Remote level disagrees with sounding | Re-sound with trim correction | Sensing line blocked; bubbler air off; transmitter drift | Trust the sounding; clean and re-zero |
| Filter ΔP high, constant backflush | Which sea chest; water clarity | Silt; torn or blinded screen | Change to high chest; open and clean the screen |
| UV cutting flow on low intensity | Lamp hours; sleeve fouling; water clarity | Aging lamps; fouled sleeves; murky water | Clean sleeves; change lamps; slow the pumps |
| TRO low on uptake | Salinity; cell condition | Fresh or brackish water; scaled cells | Low-salinity mode per plan; descale cells |
| TRO high on discharge | Neutralizer tank; dosing pump | Tank empty; pump failed; sensor fouled | Stop discharge; refill or repair; clean sensor |
| BWTS faulted, operation stopped | Alarm list; power and air supply | Lamp, sensor, valve, or flow fault | Reset once; repair; master's contingency decision if not |
Work out what you’d do, then open it.
Filling No. 4 wing starboard from the control room. The mimic shows the valve open, the pump is running at normal pressure, and ten minutes later the remote level has not moved. Where does the water go, and what do you do?
Somewhere is filling — the pump is moving water and the discharge pressure says so. Check every tank level on the panel for one that is rising; if a tank reads shut and is rising, that valve stopped short. If nothing is rising, the pump is going round a crossover back to sea or into the tank you just finished. Send someone to No. 4 starboard's local indicator; a stalled actuator shows shut or half-open regardless of the lamp. Open it on the hand pump if the mate still wants the tank, and shut whatever was taking the water. Afterward, fix the limit switch and sound both tanks by hand — the plan's figures are now wrong.
Deballasting in port for cargo, four tanks down, six to go. The UV unit trips on low intensity and will not reset. The mate needs the tanks empty to keep loading. What are the options?
There is no bypass for convenience. Reset once, with the Chief's knowledge; if it trips again, the deballast stops. Find the cause — lamp failure, sleeve fouling, a flow sensor — and fix it if it is on board; a lamp change is an hour, sleeves are a few hours. Tell the mate how long, so loading can be re-sequenced; cargo can often go to holds whose ballast is already out. If repair is not possible, the master decides under the plan's contingency section — discharge to a reception facility, retaining the ballast and loading less, or, with port authority and flag agreeing, a reported discharge. Every step goes in the record book with times. What nobody does is open a valve around the unit.
A ballast pump's shaft seal has been renewed. On its first sea-to-sea run alongside, the mate reports a sheen at the overboard. What happened, and what should have been done?
Oil left in the pump and casing from the repair — or a seal that is not tight — has gone over the side with the first water. Stop the pump, tell the Chief and the mate, and get containment out; it is now a reportable event. Then work out which: if the sheen stops after a short run, it was residue; if it comes back, the seal is leaking. Before refitting a submerged pump, air-test the shaft seal to 3 bar and hold it an hour. Expect residue anyway, and make the first run at sea.
The remote valve hydraulic power unit loses both pumps mid-operation. What stops, and in what order?
Every remote valve stops where it is. The accumulator gives a few strokes — use them on whatever must shut now: the tank about to overfill, then the sea suction. After that, every valve is a hand pump or handwheel at the valve, in the duct keel or on deck. Running pumps are pushing against whatever is open, so stop them unless the open line-up is safe. The ballast operation is now as slow as the walk to each valve, and the mate needs to know the plan's timing is gone. Fix the HPU — electrical supply, pump coupling, relief valve stuck open, reservoir emptied by a hose burst — before anything else on the ballast side moves.