Part I · The Plants

Ballast and Ballast Water Treatment

The ballast system moves seawater into and out of the double bottom, wing, peak, and topside tanks so the ship floats at the draft, trim, and stability the mate needs. The treatment system kills what lives in that water on the way in or out, and the ballast record book proves it.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Ballast pump capacity200–1,500 m³/h each, two pumps
Pump discharge pressure2–3.5 bar
Pump suction0 to −0.4 bar from a low tank; near zero from the sea
Extra discharge pressure through the treatment plant0.5–1 bar
Eductor driving pressure6–9 bar
Remote valve hydraulic system100–150 bar
Pneumatic valve air6–8 bar
Valve travel, open to shut30–90 s
Remote tank gauge dead band near the bottomseveral m³; log what each reads empty
Submerged pump shaft seal air test after repair3 bar, held 1 h
BWTS filter screen20–50 µm
Filter ΔP backflush trigger0.3–0.5 bar
UV intensity or transmittanceabove maker's minimum, by alarm
TRO at injection (electrochlorination)5–10 mg/L as Cl₂
TRO at discharge after neutralizationbelow 0.1–0.2 mg/L
D-2 discharge standard<10 viable organisms/m³ at ≥50 µm; <10/mL at 10–50 µm
D-1 exchange, where still allowed95 % volumetric; 200 nm from land, 200 m depth

The tour

The plant, stop by stop, as the book walks it.

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Valve lamp says open, tank level not changingLocal position indicator; feel the pipeActuator stalled; limit switch false; hydraulic supply lostOperate locally; correct the limit switch after
Valve lamp says shut, tank level changingLocal indicator; neighboring valvesValve stopped short; seat torn; crossover openShut locally; check the whole line-up for passing valves
Valve slow, stops midway, or will not moveHydraulic pressure or control air; local indicatorHPU pump worn; hose leak; air in the system; wet control airJog it from the panel; operate locally; find the leak
Pump noisy, discharge pressure swingingTank level; strainer; suction valveCavitation on a low tank; choked strainerStop; eductor for the rest; clean strainer
Pump quiet, no discharge, low ampsPriming unit; suction line-upAir in casing; priming failed; suction open to an empty tankPrime; correct line-up
Priming unit runs non-stopSuction side joints; sounding pipe capsAir leak on suctionSoap test flanges; close the cap
HPU pumps short-cyclingCycle time against the logged baselineLow accumulator precharge; internal leakRecharge the accumulator; find the leak
Sheen at the overboard after a pump seal repairPump just returned to service?Residual oil from the repair; seal not tightStop; contain; re-test the seal
Water from a vent head on deckTank level; which valve is openTank overfilled; valve passing; wrong tankShut the valve; tell the mate; sound the tank
Tank will not drain below a levelTrim; eductor; suction wellTrim; eductor not lifting; mudEductor; adjust trim with the mate; sound by hand
Remote level disagrees with soundingRe-sound with trim correctionSensing line blocked; bubbler air off; transmitter driftTrust the sounding; clean and re-zero
Filter ΔP high, constant backflushWhich sea chest; water claritySilt; torn or blinded screenChange to high chest; open and clean the screen
UV cutting flow on low intensityLamp hours; sleeve fouling; water clarityAging lamps; fouled sleeves; murky waterClean sleeves; change lamps; slow the pumps
TRO low on uptakeSalinity; cell conditionFresh or brackish water; scaled cellsLow-salinity mode per plan; descale cells
TRO high on dischargeNeutralizer tank; dosing pumpTank empty; pump failed; sensor fouledStop discharge; refill or repair; clean sensor
BWTS faulted, operation stoppedAlarm list; power and air supplyLamp, sensor, valve, or flow faultReset once; repair; master's contingency decision if not

Scenarios

Work out what you’d do, then open it.

open valve, dry tank

Filling No. 4 wing starboard from the control room. The mimic shows the valve open, the pump is running at normal pressure, and ten minutes later the remote level has not moved. Where does the water go, and what do you do?

Somewhere is filling — the pump is moving water and the discharge pressure says so. Check every tank level on the panel for one that is rising; if a tank reads shut and is rising, that valve stopped short. If nothing is rising, the pump is going round a crossover back to sea or into the tank you just finished. Send someone to No. 4 starboard's local indicator; a stalled actuator shows shut or half-open regardless of the lamp. Open it on the hand pump if the mate still wants the tank, and shut whatever was taking the water. Afterward, fix the limit switch and sound both tanks by hand — the plan's figures are now wrong.

BWTS fault in port

Deballasting in port for cargo, four tanks down, six to go. The UV unit trips on low intensity and will not reset. The mate needs the tanks empty to keep loading. What are the options?

There is no bypass for convenience. Reset once, with the Chief's knowledge; if it trips again, the deballast stops. Find the cause — lamp failure, sleeve fouling, a flow sensor — and fix it if it is on board; a lamp change is an hour, sleeves are a few hours. Tell the mate how long, so loading can be re-sequenced; cargo can often go to holds whose ballast is already out. If repair is not possible, the master decides under the plan's contingency section — discharge to a reception facility, retaining the ballast and loading less, or, with port authority and flag agreeing, a reported discharge. Every step goes in the record book with times. What nobody does is open a valve around the unit.

sheen after a seal repair

A ballast pump's shaft seal has been renewed. On its first sea-to-sea run alongside, the mate reports a sheen at the overboard. What happened, and what should have been done?

Oil left in the pump and casing from the repair — or a seal that is not tight — has gone over the side with the first water. Stop the pump, tell the Chief and the mate, and get containment out; it is now a reportable event. Then work out which: if the sheen stops after a short run, it was residue; if it comes back, the seal is leaking. Before refitting a submerged pump, air-test the shaft seal to 3 bar and hold it an hour. Expect residue anyway, and make the first run at sea.

hydraulic unit down

The remote valve hydraulic power unit loses both pumps mid-operation. What stops, and in what order?

Every remote valve stops where it is. The accumulator gives a few strokes — use them on whatever must shut now: the tank about to overfill, then the sea suction. After that, every valve is a hand pump or handwheel at the valve, in the duct keel or on deck. Running pumps are pushing against whatever is open, so stop them unless the open line-up is safe. The ballast operation is now as slow as the walk to each valve, and the mate needs to know the plan's timing is gone. Fix the HPU — electrical supply, pump coupling, relief valve stuck open, reservoir emptied by a hose burst — before anything else on the ballast side moves.

Dependencies

Needs
  • Electrical — ballast pumps, HPU pumps, BWTS, control room panel; a second generator for the BWTS
  • Hydraulic power unit — remote valves; hand pumps as the fallback
  • Compressed air — pneumatic valves where fitted, bubbler level gauges, BWTS control air
  • Seawater — sea chests shared with the cooling system
  • Fire main — eductor driving water; a fire/GS pump for the peaks on some ships
Feeds
  • Stability, draft, trim, and hull stress — the mate's whole plan
  • Cargo operations — loading and discharging rates are paced by ballast
  • The cooling system's sea suction, when a choked ballast strainer is a shared strainer
  • The ship's clearance to sail — record book and treatment system compliance

Draft: this page is drawn from the book manuscript and is still being checked.