Part III · The Engines · Stage 1 · Before your first watch

Auxiliary Engines

The auxiliary engines are the four-stroke trunk-piston diesels that drive the ship's service generators, plus the small ones kept for the worst day: emergency generator, emergency fire pump, lifeboat. They run the main engine's loop (see The Main Engine as a Loop) at one fixed speed, with valves in the head and one oil for every job — and a new third owns them long before the main engine.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Speed at 60 Hz720, 900, or 1,200 rpm1,800 rpm (1,200 on some)
LO pressure at the gallery4–6 bar3–5 bar
LO temperature55–70 °C inlet80–105 °C in the sump
Jacket outlet75–90 °C80–95 °C, thermostat-held
Charge air after the cooler40–60 °C40–60 °C; none if naturally aspirated
Exhaust after each cylinder350–500 °C at load, all within about 30 °COften only manifold or turbine inlet
Oil BN30–40 on HFO10–15 on distillate
Valve lash, set coldA few tenths of a mm to about 1 mm; exhaust usually widerThe same
Lowest steady load on HFOAbout 45–50 %—
Overspeed trip110–115 % of rated speedThe same

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
No start attempt, or won't crankInterlocks; battery volts while crankingTurning gear in; prelube not proven; shutdown latched; flat batteryClear the cause — never bypass an interlock
Pinion out but not spinning, or slow crankingAir valve on the starter motor; regulatorValve vibrated shut; dirty solenoid; worn air motorFree the valve; rebuild the starter
Cranks, won't fireFuel pressure; racks; stop solenoidAir in the fuel; gummed racks; stop solenoid held; cold engineBleed; free racks; preheat
Start fail, engine firedPanel rpm while crankingSpeed pickup dead or gapped wrongProve and gap it; bottom of the standby order until proven
Black smoke under loadkW; charge air pressure; exhaust spreadOverload; air short; one unit over-fueled; worn injectorsSecond set on; find the unit
White smoke on a cold start that doesn't clearJacket temperature at start; fuel for waterCold standby — normal briefly; water in the fuel; coolant into a cylinder; low compressionPreheat; drain the service tank; pressure-test the head
HuntingAlone or in parallel; racks by handSticky racks; governor oil low or aired; gain; MGO under 2 cStExercise racks; governor oil; then the governor
One cylinder hotIts injector; its lashDribbling injector; tight exhaust lash; rack highInjector, then lash
One cylinder coldPump body by hand; lashPump leaking or choked; injector; lash badly off; low compressionPump, injector, lash — in that order
All exhausts high at the same kWCharge air temperature; filter ΔPCharge air cooler or turbocharger fouled; LT hot; exhaust leak at the turbochargerWash; filters; clean the cooler
LO pressure lowLevel; temperature; filter ΔPLow level; hot or fuel-thinned oil; filter bypassing; worn bearingsRestore; unload and stop if it keeps falling
Level rising, oil thinLeak-off per unit; under rocker coversFuel dilutionFind the leak; change the oil
Milky oil, or head tank fallingHead tank for oil; proper sample pointLO cooler; liner O-ring; cracked headStop and find it — a purifier won't beat a live leak
Overspeed tripStart, load rejection, or after governor work?Governor or actuator; rack stuck at fuel; load dumpedRacks free before restart; compare exhausts at first load — valve float can bend a valve

Draft: this page is drawn from the book manuscript and is still being checked.