The auxiliary engines are the four-stroke trunk-piston diesels that drive the ship's service generators, plus the small ones kept for the worst day: emergency generator, emergency fire pump, lifeboat. They run the main engine's loop (see The Main Engine as a Loop) at one fixed speed, with valves in the head and one oil for every job — and a new third owns them long before the main engine.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical | |
|---|---|---|
| Speed at 60 Hz | 720, 900, or 1,200 rpm | 1,800 rpm (1,200 on some) |
| LO pressure at the gallery | 4–6 bar | 3–5 bar |
| LO temperature | 55–70 °C inlet | 80–105 °C in the sump |
| Jacket outlet | 75–90 °C | 80–95 °C, thermostat-held |
| Charge air after the cooler | 40–60 °C | 40–60 °C; none if naturally aspirated |
| Exhaust after each cylinder | 350–500 °C at load, all within about 30 °C | Often only manifold or turbine inlet |
| Oil BN | 30–40 on HFO | 10–15 on distillate |
| Valve lash, set cold | A few tenths of a mm to about 1 mm; exhaust usually wider | The same |
| Lowest steady load on HFO | About 45–50 % | — |
| Overspeed trip | 110–115 % of rated speed | The same |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| No start attempt, or won't crank | Interlocks; battery volts while cranking | Turning gear in; prelube not proven; shutdown latched; flat battery | Clear the cause — never bypass an interlock |
| Pinion out but not spinning, or slow cranking | Air valve on the starter motor; regulator | Valve vibrated shut; dirty solenoid; worn air motor | Free the valve; rebuild the starter |
| Cranks, won't fire | Fuel pressure; racks; stop solenoid | Air in the fuel; gummed racks; stop solenoid held; cold engine | Bleed; free racks; preheat |
| Start fail, engine fired | Panel rpm while cranking | Speed pickup dead or gapped wrong | Prove and gap it; bottom of the standby order until proven |
| Black smoke under load | kW; charge air pressure; exhaust spread | Overload; air short; one unit over-fueled; worn injectors | Second set on; find the unit |
| White smoke on a cold start that doesn't clear | Jacket temperature at start; fuel for water | Cold standby — normal briefly; water in the fuel; coolant into a cylinder; low compression | Preheat; drain the service tank; pressure-test the head |
| Hunting | Alone or in parallel; racks by hand | Sticky racks; governor oil low or aired; gain; MGO under 2 cSt | Exercise racks; governor oil; then the governor |
| One cylinder hot | Its injector; its lash | Dribbling injector; tight exhaust lash; rack high | Injector, then lash |
| One cylinder cold | Pump body by hand; lash | Pump leaking or choked; injector; lash badly off; low compression | Pump, injector, lash — in that order |
| All exhausts high at the same kW | Charge air temperature; filter ΔP | Charge air cooler or turbocharger fouled; LT hot; exhaust leak at the turbocharger | Wash; filters; clean the cooler |
| LO pressure low | Level; temperature; filter ΔP | Low level; hot or fuel-thinned oil; filter bypassing; worn bearings | Restore; unload and stop if it keeps falling |
| Level rising, oil thin | Leak-off per unit; under rocker covers | Fuel dilution | Find the leak; change the oil |
| Milky oil, or head tank falling | Head tank for oil; proper sample point | LO cooler; liner O-ring; cracked head | Stop and find it — a purifier won't beat a live leak |
| Overspeed trip | Start, load rejection, or after governor work? | Governor or actuator; rack stuck at fuel; load dumped | Racks free before restart; compare exhausts at first load — valve float can bend a valve |