This is both ends of the loop in The Main Engine as a Loop: the air that goes in, the exhaust that comes out, and the turbocharger that uses one to pull in the other. The engine can only burn what it can breathe, so most "all cylinders hot" and "power down at the same fuel" problems start here.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Scavenge (charge) air pressure, full load | 2.5–4 bar; near zero at dead slow with the blowers running |
| Air after the compressor / after the cooler | 150–200 °C / 35–50 °C; high alarm commonly 55–65 °C |
| Filter and cooler air-side ΔP | Recorded clean; act at about half again above baseline |
| Turbocharger speed, large main engine units | Roughly 7,000–20,000 rpm; steady at steady load |
| Exhaust at each cylinder outlet | 300–450 °C; all units within about 30 °C |
| Exhaust before / after the turbine | 350–500 °C / 230–350 °C; the drop steady for a load |
| Exhaust back-pressure after the turbine | Under about 300 mm WC (30 mbar) |
| Scavenge space temperature, each unit | Close to charge air temperature, all units alike |
| T/C bearing oil | Engine-fed: 1–2 bar, header tank glass flowing. Own sump: level in the glass, oil clear |
| Auxiliary blowers | Cut in below about 0.4–0.6 bar scavenge pressure (roughly 30–40 % load) |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Scavenge pressure low, T/C rpm low, all exhausts up | Back-pressure; lagging for leaks | Turbine side fouled; exhaust leak before the turbine; economizer fouled | Dry-clean; soot blow; fix the leak |
| Scavenge pressure low, T/C rpm high | Filter and cooler ΔP | Compressor, filter, or cooler fins fouled; nozzle ring; flap passing | Wash compressor; clean mats; fin wash |
| Charge air hot, LT at set point | LT in and out; isolation valves | Cooler fouled either side; valves leaking by; dirty compressor | Backflush; wash compressor; see Heat Exchangers |
| Heavy water at cooler drains; one unit's drain wet | Sea temperature; load | Cooler too cold; catcher damaged; drains blocked | Reduce LT per maker; clear drains |
| Surging | What changed; ΔPs; back-pressure; per-unit exhausts | Load drop; fouling; flaps; a unit not firing | Steady the load; wash and dry-clean |
| T/C vibration, bearing temperature rising | Oil pressure and color; recent washing | Uneven deposits; blade damage; bearing wear | Reduce load; wash again; prepare to cut out |
| Blue smoke; T/C oil black fast | Sealing air line; sump level | Labyrinths worn; sealing air weak; sump overfilled | Clear sealing air; correct level; seals at overhaul |
| Intake mats sooting in days | Joints and compensators | Exhaust leak nearby | Change mats; fix the leak |
| One unit's scavenge temperature rising, smoke at its drain | That unit's exhaust | Scavenge fire; blow-by | Scavenge fire procedure |
| Blowers cycling | Scavenge pressure against set points | Load in the hysteresis band | Manual until above the band |
| Back-pressure rising, exhausts up | Economizer ΔP and outlet temperature | Sooted tubes | Soot blow; wash per Steam Plant |
| T/C rpm zero or jumping, engine fine | Pickup and cable | Speed pickup fault | See Sensors and Alarm Systems |
| Sparks at the funnel | Economizer temperatures; per-unit exhausts | Soot fire starting; poor injectors or valve lash on a generator | Steam Plant soot fire response; injectors and lash |
Draft: this page is drawn from the book manuscript and is still being checked.