An air compressor draws in free air, squeezes it in one or more stages, and pushes it into a receiver. Every type is judged the same way: how fast it fills the receiver, what the stage pressures and temperatures say, and how much oil it uses.
Lessons teach one thing step by step. Simulators are free play: best after the lesson.
Maker’s values override these.
| Point | Typical |
|---|---|
| Starting air compressor discharge | 25–30 bar |
| Interstage, two-stage 30 bar machine | 3–5 bar |
| Service / working air compressor discharge | 7–10 bar |
| Air temp leaving each stage, reciprocating | 120–180 °C |
| Air temp after aftercooler | cooling water temp + 10–15 °C |
| Crankcase LO pressure, pressure-lubricated recip | 2–4 bar |
| Sump level | inside the maker's band — never above it |
| Screw discharge temp (air and oil) | 75–95 °C; trip around 110–120 °C |
| Screw separator element ΔP — new / change | under 0.3 / 0.7–1.0 bar |
| Screw oil carryover, good element | 1–3 ppm |
| SCBA compressor final pressure | 200 or 300 bar |
| Pump-up time, any compressor | your own logged baseline |
Each one is a set of readings. Decide what they mean and what you’d check first, then look.
| Symptom | Check first | Likely causes | Action |
|---|---|---|---|
| Pump-up time longer than baseline | Interstage pressure; valve cover temps | Valves leaking; worn rings; unloader hanging open; inlet filter blocked | Inlet filter; unloader; then valve overhaul |
| Interstage low | 1st-stage valve covers by hand | 1st-stage valve leaking or broken; inlet filter; 1st-stage unloader passing | Change the hot valve; filter |
| Interstage high, interstage relief lifting | When the valves were last done | 2nd-stage valve reversed or leaking; 2nd-stage plate broken | Check orientation and condition |
| 1st-stage relief lifting, no recent valve work | Oil use; pump-up time | Scored cylinder or worn stepped-piston rings passing 2nd to 1st | Pull the piston; hone or replace liner |
| Discharge temp high, worse in hot weather | CW ΔT across cooler; air-cooled fins | Fouled intercooler or aftercooler; low CW flow; leaking discharge valve | Clean coolers both sides; restore flow |
| Oil use rising | Sump level band; oil grade | Overfilled; wrong oil; worn rings or scraper rings | Correct level and grade; ring overhaul |
| Amps high, tripping on overload | Turn it by hand; lubricator feeds | Seizing piston; valve fault; unloader not unloading at start | Open and inspect before blaming the motor |
| Glitter in sump, knock | Stop it | Bearing or piston wear; broken valve; loose valve hardware in cylinder | Open up before running again |
| Compressor runs, little air, normal sound | Unloader | Unloader full of debris; seal hardened; solenoid sticking | Overhaul or replace unloader; look for the source of debris |
| Screw trips on high discharge temp | Oil level; cooler; room temp | Low oil; fouled oil cooler; thermostatic valve stuck; blocked oil filter; hot space | Restore level; clean cooler; renew thermostat or filter |
| Screw oil in downstream air and drains | Separator ΔP; oil level | Element saturated or ruptured; scavenge line or orifice blocked; overfilled | Change element; clear scavenge line; correct level |
| Screw oil milky | Run pattern | Short loaded cycles — machine never gets hot enough to boil water out; cooler leak on water-cooled units | Change oil; raise thermostat per maker; adjust lead/lag |
| Emergency compressor won't start or fills slowly | Battery, fuel, power; timed fill | Dead battery; seized; worn valves or rings | Fix now, not when you need it |
Draft: this page is drawn from the book manuscript and is still being checked.