Part II · The Equipment · Family 1 · Move It · Stage 1 · Before your first watch

Air Compressors

An air compressor draws in free air, squeezes it in one or more stages, and pushes it into a receiver. Every type is judged the same way: how fast it fills the receiver, what the stage pressures and temperatures say, and how much oil it uses.

Lessons and simulators

Lessons teach one thing step by step. Simulators are free play: best after the lesson.

LessonThe Control SchematicMAC1’s starter on one control schematic: tap the eight loads, read back from the M coil, see what drawn de-energized means when running, find K2’s contacts by name, then find why it won’t start in Auto.LessonBefore You Open the BoxMAC1 trips ten seconds after every start. Five minutes before the screwdriver: the drawing, the alarm history and the log, what changed last, and only then the box.LessonPlant Tour: Compressed AirWalk Hawsepiper’s compressed air plant stop by stop on one drawing of the engine room, from MAC1 and MAC2 to the air start valves and the control air header: what to look at, what normal reads, a call at each stop; then eight sets of readings.Simulator · free playFault BenchStarters with a fault you cannot see: operate them, read volts, ohms and amps on any terminal, find the fault, fix it and prove it. Twelve circuits (across-the-line pump, hold bilge pump on floats, wye-delta, a standby pump that starts on low pressure, a starting air compressor with its unloader and trips, and the sewage plant three ways: on floats with its blower, and two timer-run plants; the engine room crane hoist, reversing, with its limits and brake; a generator breaker's closing and tripping circuits in TEST; and an alarm system cabinet with two 4–20 mA loops and two switch inputs; and a hydrophore pump run by a PLC, where the program is your meter) and 250 faults at random.Simulator · free playTwo-Stage Air CompressorRun a two-stage starting air compressor and diagnose leaking valves and fouled coolers from stage pressures and temperatures.

What kills it

Normal numbers

Maker’s values override these.

PointTypical
Starting air compressor discharge25–30 bar
Interstage, two-stage 30 bar machine3–5 bar
Service / working air compressor discharge7–10 bar
Air temp leaving each stage, reciprocating120–180 °C
Air temp after aftercoolercooling water temp + 10–15 °C
Crankcase LO pressure, pressure-lubricated recip2–4 bar
Sump levelinside the maker's band — never above it
Screw discharge temp (air and oil)75–95 °C; trip around 110–120 °C
Screw separator element ΔP — new / changeunder 0.3 / 0.7–1.0 bar
Screw oil carryover, good element1–3 ppm
SCBA compressor final pressure200 or 300 bar
Pump-up time, any compressoryour own logged baseline

Reading the gauges

Each one is a set of readings. Decide what they mean and what you’d check first, then look.

Symptoms

SymptomCheck firstLikely causesAction
Pump-up time longer than baselineInterstage pressure; valve cover tempsValves leaking; worn rings; unloader hanging open; inlet filter blockedInlet filter; unloader; then valve overhaul
Interstage low1st-stage valve covers by hand1st-stage valve leaking or broken; inlet filter; 1st-stage unloader passingChange the hot valve; filter
Interstage high, interstage relief liftingWhen the valves were last done2nd-stage valve reversed or leaking; 2nd-stage plate brokenCheck orientation and condition
1st-stage relief lifting, no recent valve workOil use; pump-up timeScored cylinder or worn stepped-piston rings passing 2nd to 1stPull the piston; hone or replace liner
Discharge temp high, worse in hot weatherCW ΔT across cooler; air-cooled finsFouled intercooler or aftercooler; low CW flow; leaking discharge valveClean coolers both sides; restore flow
Oil use risingSump level band; oil gradeOverfilled; wrong oil; worn rings or scraper ringsCorrect level and grade; ring overhaul
Amps high, tripping on overloadTurn it by hand; lubricator feedsSeizing piston; valve fault; unloader not unloading at startOpen and inspect before blaming the motor
Glitter in sump, knockStop itBearing or piston wear; broken valve; loose valve hardware in cylinderOpen up before running again
Compressor runs, little air, normal soundUnloaderUnloader full of debris; seal hardened; solenoid stickingOverhaul or replace unloader; look for the source of debris
Screw trips on high discharge tempOil level; cooler; room tempLow oil; fouled oil cooler; thermostatic valve stuck; blocked oil filter; hot spaceRestore level; clean cooler; renew thermostat or filter
Screw oil in downstream air and drainsSeparator ΔP; oil levelElement saturated or ruptured; scavenge line or orifice blocked; overfilledChange element; clear scavenge line; correct level
Screw oil milkyRun patternShort loaded cycles — machine never gets hot enough to boil water out; cooler leak on water-cooled unitsChange oil; raise thermostat per maker; adjust lead/lag
Emergency compressor won't start or fills slowlyBattery, fuel, power; timed fillDead battery; seized; worn valves or ringsFix now, not when you need it