The seventh sheet of Part 9. A motor at 40 megohms is still well over the book’s working floor of two megohms (the book’s own line, not a legal limit). A motor that was at 160 in February and 80 in May is going to fail, at the worst time unless it is planned out. This log is the single most useful thing an ETO leaves behind, and most ships don’t have one. Start it.
The log. One page per motor and alternator, one line per reading: the date, the frame temperature and the one-minute figure. Taken on a schedule, and every time the motor is opened.
Reading it. Read it as a trend, not as a number. The motor falling by half each quarter is going to fail, and it is going to fail at the worst time unless it is planned out; the one that dropped after a wash-down and recovered was wet. Compare readings at similar temperatures: insulation resistance roughly halves for every 10 °C the winding warms (4.2).
The question (from 9.8). Which three motors have the worst megger trend, and what is the plan for each?